E-mail
sales@gmci-china.cn
-
Phone
13817443004
-
Address
Room 703, Building B, No. 455 Yanzhan Road, Songjiang District, Shanghai
Dianlishi (Shanghai) Electronics Co., Ltd
sales@gmci-china.cn
13817443004
Room 703, Building B, No. 455 Yanzhan Road, Songjiang District, Shanghai
Medical vital sign simulation instrumentApplication scope:
Uni Sim is a handheld, battery powered six in one multifunctional physiological signal simulator. It can simultaneously provide non-invasive blood pressure, blood oxygen saturation, standard electrocardiogram and cardiac pathology signals, electronic performance signals, temperature, invasive pressure, respiration and many other functional physiological signal parameters for testing. It is one of the valuable tools for daily quality control inspection work.
By adopting advanced new technologies in blood oxygen and non-invasive blood pressure simulation, it is possible to create and upload manufacturer calibrated data curves, which overall improves the accuracy of test readings.
By combining the Med eBase database management software with a series of peripheral accessories that support Bluetooth communication, users can easily and quickly edit, create, and generate the required test sequences for automated testing on site (with pre built JJG1163 multi parameter monitor calibration specifications), download and print test results in real time, and manage a large amount of asset data information.


PULS-R blood oxygen simulation refers to an optional accessory of UNI-SIM and SP SiM blood oxygen signal simulators, which can quickly detect the working accuracy of blood oxygen finger clips and blood oxygen modules through optical testing methods. It can simulate blood oxygen levels as low as 30%, using pre programmed R-curves from specific manufacturers to simulate accurate blood oxygen concentration simulations at a resolution of 1%. The optical measurement method supports 17 preset default curves: Masimo cal(PULS-R), Mindray(PULS-R),Necollor N-560 Cal (PULS-R), Nellcor Oximax(PULS-R), Nellcor(PULS-R),Nonin(PULS-R), Novametrix(PULS-R), Nihon Kohden(PULS-R), Criticare(PULS-R), GE Ohmeda(PULS-R), GE Tuffsat(PULS-R), Philips MP cal(PULS-R), Philips / HP(PULS-R), Beijing Choice(PULS-R),BCI Cal(PULS-R) ,GE Masimo cal(PULS-R),Mindray T CAL, Open database allows users to upload custom curves in the later stage
The measurement accuracy of blood pressure readings can be ensured by the blood pressure envelope curve (O-curve) calibrated by the manufacturer of the built-in blood pressure device, which shows the relationship between pulsation amplitude and pressure. The preset blood pressure curve can be agreed upon, including GE Procare,Marquette Eagle,GE Dash,Omron IntelliSense,PHILIPS_IntelliVue_MP,Philips_SureSigns,Datex-Omeda S5,Datascope Passport,Welch Allyn Propaq,Spacelabs ,Criticare,Colin Wait, new curves can be added to the open database in the later stage
The optional rigid gas volume with adjustable pressure can achieve rapid pressure regulation/release, and the continuous pressure reduction method can be used to quickly verify the static pressure indication of the monitor.

The handheld portable bag allows you to operate it with just one handheld device, making it convenient to write and record data.
A highly integrated multi parameter standard signal simulator suitable for precise detection of medical electrocardiographs, multi parameter monitors, electronic blood pressure monitors, and pulse oximeters
Medical vital sign simulation instrumentTechnical Specifications:
Non invasive blood pressure testing
Test type oscilloscope method
The accuracy of blood pressure indication can be ensured through the blood pressure envelope curve (O-curve) of the relationship between pulsation amplitude and pressure calibrated by the blood pressure device manufacturer, ensuring non-invasive blood pressure indication accuracy. The preset includes Mindray,GE Procare,Marquette Eagle,GE Dash,Omron IntelliSense,Philips_IntelliVue_MP,Philips_SureSigns,Datex-Omeda S5,Datascope Passport,Welch Allyn Propaq,Spacelabs ,Criticare,Colin Wait, new curves can be added to the open database in the later stage
Systolic/diastolic blood pressure range 10-300mmHg
Users can manually set the range: 10-250mmHg
Pre set blood pressure with 10 optional values, which can be added according to testing needs
JJG 693 150/100 adults, 60/30 children, including envelope curve ± 3
Default:60/30,80/40,100/60,120/80,140/100,150/100,180/140,220/180,240/200,255/195
Custom blood pressure is available
Simulated cuff external cuff method
Mode: Adult, Child
Pulse volume high, medium, low
Pulse rate 20-300 bpm
Built in air pump 0~350 mmHg user-defined
System air tightness 0~350 mmHg user-defined
Timer 0~900 seconds
Overvoltage protection automatic charging (up to 410 mmHg)
Digital pressure gauge 0~410 mmHg
Pressure accuracy ± 0.75mmHg (0-300mmHg)
±% 0.5% ( 301 - 400 mmHg )
Pressure unit mmHg, inHg, kg/cm2, cmH2O, mBar, PSI, inH2O,kPa
Range range of electronic method 50% -1; Optical method 30% -1 (PULS-R), step size 1%
Pulse rate 20-300 BPM
Accuracy ± 1 BPM
Skin color white, medium, black (electronic method only)
Pre infusion 0-20%, step size 0.1% (limited to electronic method only)
Precision timer test response to blood oxygen monitoring time
Electrocardiogram heart rate simulation
ECG standard heart rate signal generator, 12 lead output analog
Heart rate range 20-300 BPM (type value)
Heart rate accuracy ± 1 BPM
High level ECG output 3.5mm plug
ST segment analysis: elevation/inhibition
Elevation ratios of 7%, 13%, and 20%
Raise the slope positively, negatively, and horizontally
myocardial infarction
Types of ischemia, injury, infarction, inferior wall infarction
High T-wave
T-wave amplitude 0-1.2mV, step size 0.1mV, 20 selectable values
The battery life is 4-24 hours, depending on different simulation tests
Memory capacity of approximately 10000 pieces of data
Communication Bluetooth
Display monochrome, ¼ VGA full graphics
Keyboard alphanumeric
Weight<1.5 kilograms
Dimensions (length x width x height) 270 × 110 × 75mm
Operating environment 10-30 ℃, 0-90% RH - NC
Storage environment -15 ℃ -+60 ℃
Environmental protection level IP 40
Optical simulation refers to general specifications
Operating temperature 0-40 ℃
Dimensions (length x width x height) 78 × 68 × 29mm
Simulated finger shape 40 × 18mm