SafeTest 60 is a comprehensive, stable, and professional medical electrical safety analyzer. It is suitable for testing a large number of medical and laboratory equipment without patient leads, such as electric knives, medical beds, lifting machines, infusion pumps, continuous positive pressure breathing aids (CPAP), and centrifuges.
It has a full-color display screen and a color coded user interface, which allows easy selection of desired tests through buttons. At the same time, the fast step-by-step testing program makes the testing process fast and reliable.
Although small in size, SafeTest 60 includes a range of safety tests to comply with international safety standards, including leakage testing for IEC 606016235361010 and NFPA-99, grounding testing for 6235361010 and NFPA-99, and insulation testing for IEC 62353.

Manual control provides the advantage of performing specific tests as required, and provides users with full control over the power cycle, making testing simple, convenient, and fast. The automatic warning of the secondary earth/ground path ensures that users can detect invalid data and obtain correct and accurate test results at the primary time every time.
SafeTest 60 comes with various power configurations to regulate local and international markets, as well as standard protective suitcases.
User types for SafeTest 60
Participating in medical equipment testing does not require patient testing wires, such as medical beds, operating tables, infusion pumps, medical electrocauters, lifting machines, continuous positive airway pressure (CPAP) devices, suction pumps, dental chairs, medical scales, home care equipment, etc.
Engineers test laboratory equipment and products in a medical environment.
Electrical performance/analysis function
|
IEC60601 (GB9706.1 Safety Specification for Medical Electrical Equipment) Measurement of protective grounding impedance Measurement of ground drain current Measurement of shell leakage current Patient leakage current (requires optional MD testing unit) Load current measurement Insulation impedance measurement Point to point testing (resistance, current) |
NFPA-99: Measurement of protective grounding impedance Measurement of ground drain current Measurement of shell leakage current Load current measurement Insulation impedance measurement Point to point testing (resistance, current) |
|
IEC 61010: Measurement of protective grounding impedance Contact current measurement Contact voltage measurement Load current measurement Insulation impedance measurement Point to point measurement (resistance, current) |
IEC 62353: Measurement of protective grounding impedance Equipment leakage current measurement Load current measurement Insulation impedance measurement Point to point measurement (resistance, current) |
Product Introduction:
Electrical safety testing equipment for site installation and modulation of medical equipment
Grounding continuity | |
Pre pulse |
65-25A peak current, measured from 0.1 to 0.8 ohms, used to eliminate measurement errors in oxide film resistance |
Pulse form |
exponential decay |
Decay time |
Peak current ranging from 200-550 µ s to 5% (measured at 0.1~0.8 Ω) |
measurement method |
2-line method |
measure current |
>200mA DC |
test voltage |
4-24Vrms open/closed circuit |
Range (low) |
0.001 – 0.999Ω , 分辨力0.001Ω |
Range (medium) |
1.00 – 9.99 Ω, resolution 0.01 Ω |
Range (high) |
10.0 – 19.9 Ω, resolution 0.1 Ω |
accuracy |
± 1% of the measured value, ± 5m Ω |
Test circuit protection |
At the 4mm input terminal, if the applied AC or DC voltage is ≥ 30V, the test will be interrupted |
Leakage current test (under loading state) | |
frequency response |
Provide 4 standard optional values IEC 60601 IEC 62353 NFPA-99 IEC 61010 |
GB9706.1 (IEC 60601)/AAMI standard |
Regarding ground leakage current/shell leakage current; /Patient leakage current |
GB4793.1 (IEC 61010) standard |
Contact current/contact voltage |
YY/T 0841 (IEC 62353) standard |
Equipment leakage current (direct method) |
NFPA-99 standard |
Ground leakage current/shell leakage current |
Test output voltage |
Power grid voltage |
range |
0.1-9999 μ A (typical value of 0.1-8000 μ A IEC61010) |
Measurement/display resolution |
0.1μA |
accuracy |
Range 0.1-1999uA, accuracy ± 1%, Range 2000-9999uA, accuracy ± 2% |
Power polarity |
Soft key control |
Single fault condition |
Soft key control zero wire open circuit/ground wire open circuit |
load testing | |
application |
Fire zero, fire ground, zero ground, |
range |
0.0Vac – 300Vac, Resolution of 0.1Vac |
accuracy |
± 2% ± 2 digits (10Vac – 270V ac) |
power frequency |
45.0 – 66.0Hz , Resolution of 0.1Hz |
range |
0.0A – 20.0A |
resolution |
0.1A |
accuracy |
± 5% ± 2 digits |
insulation resistance | |
measurement method |
Test object power supply end to ground (Class I), test object power supply end to housing (Class II) |
Loading voltage |
500VDC @1mA. |
Z large open/closed circuit voltage |
<600VDC |
range |
100K Ω -20M Ω± 5% ± 2 digits, resolution 0.01M Ω |
short-circuit current |
<2mA |
Point to point testing | |
Test Type |
Point-to-point grounding resistance/point-to-point leakage current |
power supply | |
Z-rated current |
20A @ 120V / 16A @ 230V |
Duty cycle (@ 21 ° C environment) |
16A~20A, 3 min. Open/10 min. Closed 10A~15A, 3 min. on/5 min. off 0A ~ 10A, sustain |
Network power supply |
90-264Vac 48-64Hz |
weight |
1.1kg; (only for the body) 2.2kg; (body and accessories) |
size |
225 x 150 x 100mm (length x width x height) |
General Specifications | |
operating language |
Chinese, English, etc |
Operating temperature |
0 ~ 40°C |
humidity |
0-98% relative humidity, non condensing |
Storage temperature |
-10 ~ 50°C |
altitude |
0-2000 meters |
Protection level |
IP 40 |
Environmental Protection Level II |
Compliant with IEC 60529 |