Application scope:
The Multi Flo infusion equipment analyzer can provide real-time flow monitoring (instantaneous, average flow rate, cumulative volume, etc.), blockage alarm monitoring, analgesic pump dosage monitoring, and human back pressure simulation functions.
Due to the need for a certain time window to stabilize traffic during traffic testing, users can choose to configure 1, 2, or 4 sets of testing channels to improve testing efficiency. Each set of testing channels is independent, allowing for simultaneous analysis of multiple devices to save testing time and provide possibilities for future upgrades and expansions.

When designing equipment, specialized infusion devices such as injection pumps and PCA pain pumps with precise infusion requirements for small flow rates and small drug doses are tested, with a volume resolution of only 10 microliters (the typical volume of deionized water droplets is approximately 40 microliters). For an injection micro pump set to a flow rate of 5ml/hr, the first set of analysis data can be obtained in about 8 seconds, ensuring fast and accurate measurement of instantaneous flow rate.

The device has a large color graphic display screen that can present data in both digital and graphic formats, with a clear visual distance of over 3 meters
The inlet and outlet are both designed on the front panel, making connection and operation very convenient
The device is equipped with a background pressure control unit that can set the end pressure of the pipeline from -200 to 600mmHg. This function can complete the evaluation of the impact of blood pressure in the human body on the infusion of the pump
Through Rigel's testing solution software Med eBase, remote (PC) control interfaces can be implemented, allowing the functionality of Multi Flo analyzers to be controlled from a computer. Each device only requires one USB connection, allowing users to connect multiple sets of test channels, thereby increasing the testing capacity in high-capacity testing environments.

function |
application |
Real time traffic measurement |
Routine analysis of infusion devices |
Human back pressure simulation |
Calibration of infusion equipment |
Blocking alarm |
Production line testing and inspection of infusion equipment |
Statistical Data - Horn Curve Analysis (Med eBase required) |
Development tool for infusion equipment research and development |
Download raw data to MS Excel (requiring Med eBase) |
Infusion equipment testing tool |
Customizable testing templates |
Assessment tools for specific applications |
administration set |
Product Introduction: A fast testing tool for performance analysis of infusion devices
flow measurement | |
display range |
0.010 to 1500 milliliters per hour |
display resolution |
> 10 μ L/hour |
measurement range |
0.100 to 1450 milliliters per hour |
Traffic accuracy | |
0.1-9.9ml/hour |
1% of reading+0.005 ml/hr |
10-700ml/hour |
1% of the reading |
701-1500ml/hour |
(1+X)% of the reading, where x=0.0033% x (flow rate -700ml/hr) |
cumulative flow |
0.001 to 9999 milliliters |
Update rate of flow velocity measurement data |
1Hz |
Sampling time interval |
1-600 seconds |
Blockage/back pressure test | |
Pressure measurement range |
-500~2500mmHg (equivalent to -66.66-333.3kPa) |
Back pressure setting range |
-200-600mmHg (equivalent to -26.66-80kPa) |
accuracy |
± 1.3KPa (10mmHg) between -500 and 1000mmHg ± 1% of the reading is between 1000-2500mmHg |
Unit selection |
Millimeter mercury column, PSI,bar, kilopascal |
Z high resolution |
1 mmHg |
PCA/Pill Measurement (Cumulative Flow) | |
display range |
0.1〜100ml |
measurement range |
0.5〜100ml |
accuracy |
± 1% of the reading |
Z high resolution |
10μL |
Base flow rate |
1〜30 ml/hr |
pressure |
Up to 2500mmHg |
General Specifications | |
storage |
15 × 24 hours, at a sampling rate of 1 second |
Overall dimensions |
300 × 204 x220mm (WxDxH) |
weight |
5 kg/11 pounds (1 route) 6 kg/13 pounds (2 routes) 8 kg/18 pounds (4 routes) |
main power supply |
90-264VAC, 50/60 Hz, 60W |
power cable |
Standard IEC 10A cable |
PC communication |
USB A |
Keyboard communication |
USB B |
display |
LCD color graphic display ¼ "VGA |
environmental conditions | |
Protection level |
IP40 |
Working pressure |
Up to an altitude of 2000 meters |
Electromagnetic Compatibility |
IEC 60529 Electromagnetic Compatibility (EMC) |
anti-interference capability |
Compliant with IEC 61326-1 Radiation Interference |
environmental conditions |
No condensation within the temperature range of 5-40 ° C |
Storage temperature |
0-50℃ |