1Waterproof membrane thickness gauge (digital dial gauge)Product Overview
The HD-10 digital dial gauge waterproof roll thickness gauge is a high-precision thickness measuring instrument, mainly used to detect the thickness of various waterproof rolls, plastic films, rubber sheets, flooring materials, and other sheet flexible materials. The device uses a high-resolution digital dial gauge as the core measuring component, with intuitive readings and high accuracy, which can meet the needs of laboratory testing and rapid on-site measurement.
Compared with traditional mechanical dial gauges, the HD-10 digital version has the advantages of digital display, high measurement resolution, convenient data reading, and avoiding manual reading errors, which can effectively improve the stability and accuracy of measurement.
This instrument is designed according to GB/T 328.14-2007 Test Methods for Building Waterproofing Membrane Part 14: Thickness Determination Standard. The measurement pressure, measurement head size, and support structure all meet the standard requirements, ensuring comparability and reliability of the measurement data. Widely used in waterproof material production enterprises, quality inspection institutions, research institutes, construction engineering testing centers, and college laboratories.
⸻
IIWaterproof membrane thickness gaugeProduct specifications and technical parameters
execution standardGB/T 328.14-2007, ISO 9863, etc
measurement range0~10mm
resolution0.01mm (optional 0.001mm version)
indication error≤±0.02mm
Measure pressure2 ± 0.1 kPa (compliant with standard regulations)
Measuring head diameterΦ10mm
Measuring head materialStainless steel, precision ground treatment
Reading methodDigital LCD display
power supply1.5V button battery (SR44 or LR44)
Environmental temperature for use0~40℃
relative humidity≤85%RH
Overall dimensionsApproximately 150mm x 100mm x 230mm
Total weightAbout 1.5kg
⸻
IIIWaterproof membrane thickness gauge (digital dial gauge)structural composition
1.Digital dial indicator: high-precision electronic digital display, direct display of measured values, supporting unit switching (mm/inch).
2.Measuring head: 10mm diameter stainless steel contact, ensuring stable measurement pressure and avoiding indentation on the sample.
3.Bracket and base: sturdy and stable, ensuring vertical force during the measurement process and avoiding errors caused by tilting.
4.Lifting mechanism: The measuring head can be easily lifted by the handle, making it convenient to place or remove the sample.
5.Limit device: prevents overvoltage or overtravel, and extends the service life of the instrument.
⸻
4Waterproof membrane thickness gaugeInstructions for Use
1. Startup and preparation
•Press the ON/OFF button to turn on the digital dial indicator;
•Check the battery level and replace the button battery if necessary;
•Confirm that the display screen is reset to zero. If it is not zero, press the ZERO key to reset it to zero.
2. Measurement steps
1.Lift the measuring head higher than the thickness of the sample;
2.Place the waterproof membrane sample flat at the center of the base;
3.Slowly lower the measuring head to allow the contact to naturally touch the surface of the sample, and generate standard pressure using its own weight;
4.After the reading stabilizes, record the thickness value;
5.Each sample can be measured multiple times at different locations, and the average value is taken as the final result.
3. Data recording
•If the dial gauge has a data interface, it can be connected to a computer for automatic collection;
•When manually recording, it should be accurate to two decimal places (0.01mm).
⸻
5Rubber thickness gaugePrecautions
1.Sample placement: It must be flat without creases to avoid affecting the reading.
2.Measurement head protection: Avoid collisions with hard objects and scratches on the surface of the measurement head.
3.Pressure control: No additional pressure should be artificially applied to avoid data bias.
4.Environmental conditions: Measurement results are best in a constant temperature and low humidity environment; If there is a large temperature difference in the environment, the sample and instrument should be placed for a period of time in advance to balance the temperature.
5.Storage and maintenance: When not in use for a long time, the battery should be removed to prevent leakage and damage to electronic components.
6.Regular calibration: It is recommended to perform measurement calibration every 12 months to ensure measurement accuracy.
⸻
6、 Scope of application
The HD-10 digital dial gauge waterproof membrane thickness gauge is not only suitable for measuring the thickness of PVC, TPO, EPDM, SBS, APP and other waterproof membranes, but also for detecting the thickness of non-metallic sheet materials such as rubber sheets, plastic films, paper, leather, flooring materials, etc.
It is an important testing tool for quality control in waterproof material production factories, quality acceptance in construction projects, and scientific research and development.