The walk-in high and low temperature alternating humidity and heat test room is composed of a control panel, a distribution panel, an insulation storage board, a supply fan, a heater, a humidifier, and a freezer. The main specifications can be divided into 6 standard indoor dimensions and 24 different testing specifications under different conditions
Product Details
Equipment purpose
The walk-in high and low temperature test chamber provides the ability to simultaneously place a large number of test items for reliability testing, in order to shorten the total testing time of a single product, or to perform temperature and humidity stress screening (ESS) of the product, as well as dynamic testing that requires a large activity space. It is also suitable for products with large volumes.
The walk-in high and low temperature test chamber is an instrument and equipment used in the industry to test the environmental adaptability performance of large parts, semi-finished products, finished products, etc., such as LCD TVs, computer terminals, automotive parts, electronic devices, etc., in terms of heat resistance, cold resistance, dry resistance, and moisture resistance.
The walk-in high and low temperature test chamber is mainly composed of a control panel, a distribution panel, an insulation storage board, a supply fan, a heater, a humidifier, and a freezer. The main specifications can be divided into 6 standard indoor sizes and 24 different testing specifications under different conditions. At the same time, a large number of test items can be placed for reliability testing to shorten the total testing time of the product; It is used as a stress screening method for temperature and humidity aging.

Selection parameters


model

Customized according to size (this device can be customized as needed)

Volume (L)

9m²

13m²

17m²

27m²

35m²

43m²

Internal dimensions W * H * D (mm)

2100*2100*2050

2100*300*2050

2100*3900*205C

2100*3000*4300

2100*3900*4300

2100*4800*4300

External dimensions W * H * D (mm))

2350*3250*225C

2350*4150*2250

2350*5050*2250

2350*4150*4300

23500*5050*4500

2350*5950*4500

Temperature range (optional)

-70℃~+100°℃; -60°℃~+100℃; -40℃~+100℃; -20℃~+100°℃; 0℃~+100℃;

Room temperature~+100 ℃ (note: the general standard for high temperature range is 85 ℃, but this equipment can also be used for high temperatures of 120 ℃, 150 ℃, and 180 ℃)

temperature deviation

≤± 1.0 ℃ (unloaded)

temperature fluctuation

≤±0.3℃

Temperature Uniformity

≤± 2.0 ℃ (unloaded)

humidity range

20% R.H~98% R.H (non-standard customization options: 10% R.H~98% R.H, 5% R.H~98% R.H)

Humidity deviation

±3.0%RH

humidity uniformity

±2.0%RH(No load)

Humidity fluctuation

±2.0%RH

heating rate

From -40 ℃ to+85 ℃ ≥ 3.5 ℃/minfully loaded

降温速率

Reduce from+85 ℃ to -40 ℃ ≥ 3.5 ℃/minfully loaded

controller

7 inches or 10 inchesLCDTouch screen, Chinese/English display, Yongcheng InstrumentLCDtouchController parameter groupPIDcontrol

system

Balanced temperature and humidity control system

Inner box material

stainless steel

outer box material

Steel plate electrostatic spraying surface treatment or stainless steel

thermal insulation material

Rigid polyurethane foam and glass fiber cotton

refrigeration system

Cooling method: air-cooled or water-cooled

Refrigeration device: stacked semi enclosed compressor or single-stage fully enclosed compressor, environmentally friendly refrigerant

network connection

It can be connected to Ethernet through professional software, and remote control and assistance can be done through the network, It is also possible to collect experimental data through the network and control multiple machines simultaneously

Box door

Double door, install door frame heating wire at the door frame to prevent low temperature situationsCondensation at the door frame under certain conditions

Slope device

Slope device type 2 helps transport samples and fixtures to the interior of the equipment Child car: Type 3, Mother car: One copy, carrying products in and out of the equipmentprepare

protective device

Heater overcurrent circuit breaker

Humidifier overcurrent circuit breaker

Circulating fan overcurrent overload protection

Compressor high voltage protection switch

Compressor overheat protection switch

Compressor overcurrent protection switch

Overvoltage and under reverse phase protection switch

Line circuit breaker

Non fuse switch

Humidifier low water level protection

水箱低水位警示

Controller noise isolation protection

Zero crossing gate fluid power controller

Environmental temperature for use

Operating guarantee environmental temperature range: 5~ 35℃

power supply wattage

AC380±10PHzThree phase four wire+ground wire/3