NegotiableUpdate on 02/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The gas sensor used in the battery testing chamber should detect gas leakage from the secondary battery. After detecting the gas, activate the intake and exhaust dampers to introduce air and reduce the gas concentration. This device has a two-stage detection capability
Product Details

Product Features

1. A device with high safety functions and diverse safety structures for temperature testing of secondary batteries. In the secondary battery test, it plays a role in the event of gas leakage or fire hazard.

2.test chamberGas sensors should be used to detect gas leaks from secondary batteries. After detecting the gas, activate the intake and exhaust dampers to introduce air and reduce the gas concentration. This device has a two-stage detection and alarm system. After the gas concentration reaches the originally set alarm point, the first stage will be activated, and the second stage will also be activated when the concentration further increases.

When the secondary battery catches fire (abnormally heats up) and CO occurs, the fire extinguisher will start and automatically extinguish the fire. At this point, the operation also stops.

4. The one touch lock handle is installed on the door. Also, when the door is not tightly closed or locked, the device will not start and will sound an alarm to notify of any abnormalities. Open the door (variable) for 30 minutes during operation to stop the device from running.

5. In case of an explosion in the test chamber, the safety valve (pressure relief valve) can release the explosion pressure outward.

6. Various test chambers can be selected according to their purpose.

Product Specifications

Pressure relief valve

When abnormal gases or other substances are ejected and the internal pressure rises sharply, release the pressure and reduce the impact on the machine and its surroundings.


Gas alarm circuit


due toH TheCOGas alarm, two-stage detection alarm


Supply and exhaust baffle

When the gas concentration increases, ventilation reduces the gas concentration. Need to connect the exhaust pipe, forcibly inhale and inhale the exhaust


Strengthen the door

No observation window, increase the chain of doors


heater

Using a finned armored heater


CO, fire extinguishing device

When the temperature inside the box exceeds the temperature, carbon dioxide gas is sprayed out. Simultaneously stop running.


external alarm

Input terminal: Stop the machine after receiving an external abnormal signal. Output terminal: When there is an abnormality in this machine, it sends a signal to the outside.