Equipment purpose
Rapid temperature change test chamber(ESS) It is achieved by applying reasonable environmental and electrical stresses to the test object, so that defective components, parts, or workmanship are controlled The process of accelerating the early defects of products caused by artistic defects into malfunctions, and discovering and eliminating them, is an economically effective engineering research and manufacturing improvement Means.
Rapid temperature change test chamberEquipped with various temperature and humidity testing functions, providing you with quality and reliability verification for increasingly complex electronic and other products. The test chamber adopts Classic stainless steel features and innovative modern stylesatisfyJEDECTheIEC、And other international testing performance standards. Noise from rapid temperature change test chamberLow level temperature change rate can reach25℃/min。
Product Parameters
model |
YC-THK100 |
YC-THK225 |
YC-THK408 |
YC-THK800 |
YC-THK1000 |
Volume (L) |
100L |
225L |
408L |
800L |
1000L |
inner dimensionsW*H*D(mm) |
400×500×500 |
500*750*600 |
600*850*800 |
1000*1000*800 |
1000*1000*1000 |
External dimensions W * H * D (mm) |
620×1490×1270 |
740*1650*1850 |
840*1750*2100 |
1240*1900*2100 |
1240*1900*2250 |
temperature range |
-70-180 ℃ (optional: -60~180℃,-40~180℃) |
||||
heating rate |
10℃/minlinear(Customizable) |
||||
降温速率 |
5℃/minlinear(Customizable) |
||||
temperature fluctuation |
≤± 0.2 ℃ (no-load steady state) |
||||
temperature deviation |
≤± 2.0 ℃ (no-load steady state) |
||||
Temperature Uniformity |
≤± 1.0 ℃ (no-load steady state) |
||||
humidity range |
10%R.H~98%R.H(+10°℃~+95)℃ |
||||
Humidity fluctuation |
soil2%RH(No load steady state) |
||||
Humidity deviation |
±3.0%RH(No load steady state) |
||||
humidity uniformity |
≤5.0%RH(No load steady state) |
||||
Temperature change rate |
Heating rate: not less than2.0℃/min(-55~+85 ℃ overall average) Cooling rate: not less than2.0℃/min(Average temperature of+85~-55 ℃ throughout the entire process) |
||||
cooling method |
Air cooled (or water-cooled) |
||||
Energy saving methods |
Hot gas bypass technology+cold end self balancing technology |
||||
Inner box material |
SUS304 mirror stainless steel (customizable)SUS316 mirror stainless steel) |
||||
outer box material |
Cold plate electrostatic spraying surface treatment |
||||
refrigeration system |
Double and stacked refrigeration system+Piston compressor+environmentally friendly refrigerant R-404a/R-23 |
||||
water supply method |
Extra large water tank+automatic water replenishment device |
||||
controller |
10 inch industrial grade true color touch screen+SiemensPLC,PacoologicTemperature control module; Independent switching between Chinese and English |
||||
protective device |
Compressor overpressure protection; Compressor overcurrent protection; Compressor overheat protection; Compressor oil pressure differential protection; Over temperature protection inside the box;Heater air burn protection; Overcurrent tripping protection; Humidifier air burn protection; Fan overcurrent protection; Leakage protection; Water tank water shortage protection; |
||||
Inner box configuration |
Large insulated glass observation window, built-in top lighting, double-layer storage rack, box side lead hole. |
||||
working environment |
temperature+5 ℃ -+35 ℃ Power supply: three-phase 380V50HZ(Other power specifications can be customized) |
||||
|
meet the standard |
GB2423.1/IEC60068-2-1; GB/T2423.2/IEC60068-2-2; GB/T2423.3/IEC60068-2-78; GB/T2423.4/IEC60068-2-30; GB/T2423.22/IEC60068-2-14,GJB150.3; GJB150.4; GJB150.9; GB/T5170.18; GB/T10586; GB/T 10589 |
||||
This device is a customized product, specific requirements are subject to the specification sheet