Online monitoring system for VOCs organic pollutants(CMS-6000)
The VOCs organic pollutant online monitoring system isPureinstrumentAccording to the national regulationsThe regulation of VOCs emission standards is a VOCs online detection system developed by the technical research and development team of the company, based on the actual production process and on-site environmental conditions of relevant enterprises. It can be directly deployed on the production site of enterprises, and deployed at multiple points, distributed throughout the entire monitoring area, forming an online VOCs monitoring network. The VOCs emission status of the entire monitoring area can be controlled through the monitoring platform.
Instrument Features
1. The instrument has excellent stability and durability, and can work 24 hours a day without stopping, meeting the requirements of high-intensity online detection.
2. By adopting IoT technology, it can be installed in multiple locations within the detection area, achieving regional networking, multi-point monitoring, and key monitoring.
3. Adopting modular design, functions can be customized according to user requirements and on-site environment to meet customer needs
System Composition
System Component 1:CMS6000Series online process gas chromatograph
The main component of the VOCs organic pollutant online monitoring system is to analyze the collected organic waste gas, calculate the composition and content of VOCs substances, and provide practical data basis for the treatment and emission of VOCs in enterprises.
| project | indicator |
| detection capability | Methane, non methane total hydrocarbons, total hydrocarbons, benzene, toluene, ethylbenzene, xylene |
| range | Methane(0.1-1000)ppm; Non methane total hydrocarbons(0.05-100)ppm/(1-1000)ppm Benzene derivatives(1-10000)ppm |
| detector | Hydrogen flame ionization monitor(FID) |
| detection limit | 0.1ppm(Methane);0.05ppm(Non methane total hydrocarbons);0.1ppm(Benzene derivatives) |
| repetitiveness | RSD≤3% |
| Analysis cycle | ≤20min |
| Power supply | AC220V 50Hz 800W |
| working environment | Temperature:(5-35)℃, humidity:(20%-90%)RH |
| Air source requirements | Carrier gas: high-purity nitrogen or zero order air(>99.995%); Gas: high-purity hydrogen gas Auxiliary gas: zero grade air |
| output | 4-20mATheRS232/RS485Ethernet |
| size | 19Standard chassis |
System component 2: Temperature pressure flow module
The temperature pressure flow is connected to the sampling probe to heat, stabilize, and preprocess the collected gas. It is equipped with a shut-off valve and a blowback solenoid valve to ensure smooth delivery of the collected gasImprove the accuracy of data monitoring in the VOCs organic pollutant online monitoring system.
| temperature | 0~400 |
| pressure | -5~5kPa |
| pressure difference | 0~2kPa |
| Corresponding flow velocity | 0~20m/s |
System Component Three: Hydrogen/Air generator
onlineSeries hydrogen generators, forThe VOCs organic pollutant online monitoring system provides high-purity hydrogen gas, using potassium hydroxide solution as the electrolyte, which has the advantages of safe use and easy maintenance. It can be replaced by high-purity hydrogen gas cylinders.
| model | PRH300 | PRH500 |
| Output pressure | 0.4MPa | 0.4MPa |
| overvoltage protection | 0.46MPa | 0.46MPa |
| *Traffic volume | 300mL/min | 500mL/min |
| gas purity | Better than 99.999% | Better than 99.999% |
| Actual size | 240×350×470mm | 240×350×470mm |
| power supply | AC220V 50Hz 150W | AC220V 50Hz 150W |
| Total weight | About 17kg | About 17kg |
Zero level air generator: composed of silent, oil-free compressor, stainless steel gas tank, high-temperature catalytic oxidation furnace, two-stage drying tube and other gas circuits. Equipped with automatic adsorption to remove hydrocarbon substances from the air, providing oil-free three-stage purified air for the system
| working principle | High temperature catalytic oxidation |
| Output pressure | 0~0.6MPa |
| outbound traffic | 0~1500mL/min |
| gas purity | Hydrocarbons ≤ 0.1ppm (based on carbon) |
| Catalytic oxidation temperature | 400℃ |
| power supply | AC220V 50Hz 300W |
System Component 4: Integrated Sampling Probe for Heat Tracing and Filtering
The specially designed integrated sampling probe for heat tracing and filtration, due to the different composition of VOCs organic waste gas in different industries, some waste gases contain water vapor or smoke, which can affect the experimental results. A specially designed sampling probe for this situation, equipped with a built-in filtering system and heat tracing system, filters the collected gas and simultaneously conducts 80 ℃ high-temperature heat tracing, allowing the collected exhaust gas to smoothly enter the temperature pressure flow module.
System Component 5: Data Acquisition and Transmission Device
The data acquisition and transmission device stores the test data and operating status of the VOCs online monitoring system through digital channels, analog channels, and switch channels, and uploads the data information to the VOCs online data monitoring platform through the system's built-in 4G wireless network module. The monitoring platform can transmit control commands to the data acquisition and transmission device through the 4G network, and the data acquisition and transmission device controls the operation of the VOCs online monitoring system based on the received control commands.
System Component 6: 4G Wireless Network Module
Due to environmental limitations, some locations are unable to install wired networks for the installation of VOCs organic pollutant online monitoring systems. Therefore, a separate 4G wireless network module is configured to allow the VOCs online monitoring system to exchange data with the VOCs monitoring platform through the 4G wireless network, making it more convenient to set up monitoring networks in multiple locations.
If the environment allows, the 4G module can be replaced with a wired network, which has better data transmission stability than the 4G module.
Application field
After multi-point deployment in high pollution areas of chemical plants, pharmaceutical factories, petrochemicals, printing, spraying and other enterprises, the VOCs organic pollutant online monitoring system can form a VOCs organic waste gas emission monitoring network. Through the monitoring platform, the VOCs emission status of the entire pollution source area can be continuously monitored for 24 hours, assisting environmental protection departments in real-time understanding the pollution situation in their jurisdiction and formulating corresponding improvement measures.