Product Overview
Used for monitoring non methane total hydrocarbons in ambient air(NMHC concentration. Adopting a dual valve, dual column, and FID configuration, with high-temperature tracing throughout the process, the sample is quantified by a quantitative loop, injected with dual valves, and separated by dual chromatographic columns before entering a hydrogen flame ionization detector (FID) for detection. The total hydrocarbon (THC) and methane (CH4) concentrations in the sample are measured separately.
Product Features
Stable and secure operation, unmanned operation, and low maintenance costs.
Self protection function: When the gas supply is insufficient, the flame will automatically extinguish and the hydrogen and air flow will be actively shut off.
Automatic resumption of operation: After startup, restoration of gas supply, or unexpected power outage, it will automatically ignite.
Support remote alarm and remote diagnosis functions.
instrumentGood repeatability in qualitative and quantitative analysis(<1%), low detection limit.
NMHC detection limit as low as 10 ppm.
High stability temperature control:0.01 ℃ 。
High precision electronic pressure control:0.03psi, Temperature and pressure compensation.
Low maintenance and long service life.
The proportion of imported components is as high as40%.
The software is easy to operate.
Modular design, easy to maintain.
Applicable standard
Comprehensive Emission Standards for Air Pollutants(GB16297-1996)
Beijing Atmospheric Pollutant Emission Standards(DB11/501-2007)
Emission Standards for Pollutants in the Rubber Products Industry(GB27632-2011)
Emission Standards for Pollutants in Petrochemical Industry(GB31571-2015)
Emission Standards for Pollutants from Petroleum Refining Industry(GB31570-2015)
Pollutant Emission Standards for Synthetic Resin Industry(GB31572-2015)
Application scenarios
Suitable for monitoring benzene derivatives in environmental air, residential areas, key industrial parks, enterprise boundaries, workplaces, and other scenarios.
Technical Specifications
|
| project | parameter |
| sex can point mark | detection capability | Total hydrocarbons, methane, non methane total hydrocarbons, benzene, toluene, ethylbenzene, xylene, styrene, isopropylbenzene |
| range | Non methane total hydrocarbons: 10-10000 ppmBenzene derivatives: 0.01~300 ppm(Optional) | |
| detection limit | Non methane total hydrocarbons: 10 ppmBenzene derivatives: 0.01 ppm(Toluene) | |
| repetitiveness | Non methane total hydrocarbons:<1%; Benzene derivatives:<3% | |
| zero drift | Drift<0.5% F.S. (24h) | |
| range drift | Drift<2.0% F.S. (24h) | |
| Analysis cycle | <90 S(Optional) | |
| be unify ginseng number | Instrument size | 19 inch standard chassis, height 6 U, (430 × 266.7 × 633) mm (W × H × D) |
| Power Specifications | 220 VAC 50 Hz | |
| operating power | 500 W | |
| Input | USB; Relay and 24V power interface; LAN; RS232; VGA | |
| working environment | Temperature: 5-35 OC; humidity 20~90% RH | |
| be unify match place | detector | FID detector |
| Type of carrier gas | High purity nitrogen or zero grade air (≥ 99.999%) | |
| Quantitative method | Non methane total hydrocarbons: quantitative ring; Benzene derivatives: mass flow controller | |
| Injection method | Valve injection | |
| Sample gas requirements | Environmental temperature; Flow rate not less than 0.5 L/min or pressure not less than 0.1 MPa; No solid particles |
Gas dynamic calibrator(PR-6100 is an intelligent online gas calibration instrument. The traditional calibration method uses multiple steel cylinder gases of different concentrations to be injected and analyzed separately, and instrument calibration is performed through calibration curves. It consists of a flow control system, a gas path control system, and a computer control system. A known concentration standard gas is used to adjust different dilution ratios to obtain concentration gradients of standard gases with different contents. Fully automated operation, significantly reducing workload and saving gas distribution time.
Product Features
1. Humanized operation interface
Independently developed operation interface with few manual input items, simple and easy to operate interface
2. Provide multiple gas distribution modes to meet customers' various needs
Automatic gas distribution, manual gas distribution, sequential gas distribution
3. Support positive pressure output
Support output pressure not exceeding 0.1 MPa
4. The flowmeter accurately measures the flow rate
Using imported components to ensure the accuracy and linearity of the calibrator
Technical Specifications
| project | parameter |
| Standard gas flow range | 0~20 SLM |
| Traffic accuracy | ±1% F.S. |
| Dilution ratio | Depending on the flowmeter configuration |
| Standard gas output interface | 1/4 '' tube, British system |
| Operating temperature | 5 oC~35 oC |
| Usage environment | Indoor or cabinet interior |
| pressure of use | (0.1~0.3)MPa |
| Dilution gas flow range | (0~1000)SCCM; (0~10000)SCCM, optional |
| Traffic repeatability | ±0.2%F.S. |
| communication | LAN; RS232 |
| power input | 220VAC,50Hz |
| Operating Humidity | 5%~95% RH |
| Instrument size | (469.1×178×600)mm(W×H×D) |
The integrated sampling probe mainly consists of an air filter, a sampling rod, and a rain cover.
(1) Sampling device: Vertical laminar flow sampling manifold.
(2) Sampling head: prevents rainwater and coarse particles from falling into the main pipe, while also preventing birds, small animals, and large insects from entering the main pipe. The design of the sampling head should ensure that the sampling airflow is not affected by wind direction and enters the main pipe stably.
(3) Sampling manifold: The inner diameter of the manifold is selected to be 4cm, and the airflow inside the sampling manifold should maintain laminar flow, with low power consumption and safe voltage; Stable laminar airflow, good system airtightness, split structure, easy installation; Heating to keep dry during maintenance without cleaning, and sealing during non working conditions; The material of the sampling manifold should be stainless steel or polytetrafluoroethylene;
Airflow state parameters:
(4) Preprocessing: The preprocessing unit collects, filters, stabilizes, calibrates, and automates the sample gas, ensuring that the sample meets the operating requirements of the online analytical instrument without distortion, and guaranteeing the long-term, reliable, and accurate operation of the online analytical instrument.
The entire preprocessing unit is integrated into the cabinet, with a disk mounted structure that is aesthetically pleasing and stable;
Optimization configuration can be carried out according to specific special working conditions;
At the bottomHydrogen purity:99.999%
At the bottomHydrogen flow rate:0-300ml/min
At the bottomWork pressure:0--0.3Mpa
At the bottomPower consumption:150W
At the bottomVoltage:220V±10% 50 HZ
At the bottomFully automatic control system.
At the bottom Hydrocarbon removal effect: Removing impure substances
Nitric oxide:<1ppb
Nitrogen dioxide:<1ppb
Sulfur dioxide:<1ppb
Ozone:<1ppb
Non methane: <0.3ppb
At the bottomRemove impurities (heating reaction chamber)
carbon monoxide: < 0.1ppm
methane: <5ppb
At the bottomEconomy: More cost-effective than any other gas supply method
At the bottomConvenient: When used in conjunction with an air generator, there are no safety hazards and no need to worry about running out of gas
At the bottomSilent operation, meeting the requirements24-hour continuous operation
At the bottomCan be used online for a long time, with stable performance
meteorological parameters
| Specifications | The diameter is about 140 millimeters and the height is about 311 millimeters, Weight approximately 1.5 kilograms |
| temperature | Measurement range -50 to 85 ° C (configurable) Accuracy ± 0.2 (configurable) |
| relative humidity | Measurement range: 0-100% relative humidity Accuracy ± 2% relative humidity (configurable) |
| atmospheric pressure | Measurement range of 300-1200 hectopascals (configurable) Accuracy ± 0.3 hectopascals (configurable) |
| wind direction | Principle: Ultrasonic waves Measurement range 0-360 ° Accuracy ± 3 ° (configurable) |
| wind speed | Principle: Ultrasonic waves Measurement range: 0-60 meters/second (optional large range) Accuracy usage * value: measurement value plus or minus 0.3 meters/second or 3% |
| Basic Information | RS485 interface, dual wire connection, half duplex Operating power DC voltage 12-30V+/-10%<3 Va Working humidity range 0-100% Working temperature range -50 to 85 ° C |
The system can provide on-site data collection, query, display, preliminary statistics and analysis, determine environmental quality categories, primary pollutants and exceedance situations, automatically generate statistical reports, and print and export the reports. The actions of each actuator and sensor feedback are accurately displayed on the industrial control system interface. The industrial control interface can reflect the system process in real time, realizing the operational functions required for instrument control and status display.
It can display the values of various pollutant parameters and the operation status of the gas monitoring system in real time, directly view the concentration of various pollutants in the emitted gas, and filter, calculate, and statistically analyze the data according to relevant environmental standards and methods. It automatically generates daily, monthly, and annual reports in the format of environmental reports and stores them on designated hard drives.