VOCs online gas chromatograph, methane non methane total hydrocarbon benzene series online gas chromatography system

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Purui CMS-6000 non methane total hydrocarbon/benzene series online gas chromatograph adopts a three valve, four column, FID configuration, and high-temperature heating throughout the process. The sample is quantified by a quantitative loop, injected by three valves, separated by four columns, and detected by a hydrogen flame ionization detector (dual FID). The first FID measures the concentration of total hydrocarbons (THC) and methane (CH4) in the sample, the concentration of non methane total hydrocarbons (NMHC) is calculated by subtraction, and the second FID measures the concentration of each component of the benzene series in the sample. Suitable for monitoring the content of non methane total hydrocarbons and benzene, toluene, ethylbenzene, xylene, trimethylbenzene, etc. in pollution sources.
Product Details
Detailed content

Product Introduction

PureCMS-6000Non methane total hydrocarbons/Benzene series online gas chromatograph, using three valves, four columnsFIDEquipped with high temperature tracing throughout the process, the sample is quantified by a quantitative loop, injected with three valves, and separated by four columns before being detected by a hydrogen flame ionization detector (dual)FID)Testing, beforeFIDDetermine the total hydrocarbons in the sample(THC)And methane(CH4)Concentration, non methane total hydrocarbons(NMHC)The concentration is calculated by subtraction, and thenFIDMeasure the concentration of each component of the benzene series in the sample. Suitable for monitoring the content of non methane total hydrocarbons and benzene, toluene, ethylbenzene, xylene, trimethylbenzene, etc. in pollution sources.

Product Features:

Stable and secure operation, achieving unmanned operation and low maintenance costs:

Self protection function, when the gas supply is insufficient, the flame will automatically extinguish and the hydrogen and air flow will be turned off to prevent leakage.

Automatic ignition, automatically ignites and runs after startup, restoration of gas supply, or unexpected power outage.

instrumentGood repeatability in qualitative and quantitative analysis(≤1%)Low detection limit:

uFID detection limit as low as1.8×10-12 g/s.

uHigh stability temperature control system:0.01 ℃。

uHigh precision electronic pressure control unitEPC(0.001psi)Realize temperature and pressure compensation.

At the bottomLow maintenance and long service life: the proportion of imported parts is as high as40%.

At the bottomThe software is easy to operate and maintain,SINZEN supports customized services.

Typical spectrogram:

通道:NMHCspectrogram

通道:BETXspectrogram

Technical Specifications:

be

unify

ginseng

number

Instrument size

19Inch standard chassis, height6 U633 mm×430 mm×266.7 mm (L*W*H)

Power Specifications

220 VAC 50 Hz

operating power

500W

Analog input/output

USBRelay and24 VPower interface;LANRS232VGA

working environment

Temperature:5~35 ℃; Humidity20~90% RH

sex

can

point

mark

detection capability

Methane, total hydrocarbons, non methane total hydrocarbons, benzene, toluene, ethylbenzene, xylene, trimethylbenzene, styrene, isopropylbenzene

range

Methane, total hydrocarbons, non methane total hydrocarbons0.01~10000 ppm(Optional); Benzene derivatives0.05~1000 ppm(Optional)

detection limit

methane10 ppb

Total hydrocarbons10 ppb

Non-Methane Total Hydrocarbons (NMTHC)10 ppb

BTEX (Benzene, Toluene, Ethylbenzene, Xylenes)50 ppb

repetitiveness

<1%

zero drift

drift<0.5%F.S.24h

range drift

drift<2.0%F.S.24h

Analysis cycle

2 min~20 min (optional)

be

unify

match

place

detector

FIDdetector

Type of carrier gas

High purity nitrogen or zero order air(≥99.999%

Quantitative method

quantitative loop

Injection method

Valve injection

Sample gas requirements

Sample gas temperature: ambient temperature~180 ℃The flow rate shall not be lower than0.5 L/minOr the pressure should not be lower than0.1 MPaNo solid particles

applicationscope

At the bottomOnline monitoring of ambient air

At the bottomDischarge outlets for scientific research petrochemical, spraying, printing, etc

At the bottomOnline monitoring of factory boundary gas

At the bottomMonitoring of volatile organic pollutant emissions from fixed pollution sources

At the bottomEnvironmental protection acceptance monitoring upon completion of construction projects

At the bottomMonitoring the effectiveness of pollution prevention and control facilities

At the bottomResearch on Clean Production and Pollution Prevention Technology

At the bottomSuitable for monitoring non methane total hydrocarbons in fixed pollution source exhaust gases in industries such as rubber products, petrochemicals, petroleum refining, synthetic resins, batteries, printing, etc.

Update time: September 4, 2020 16:48:45