Comprehensive testing device for transformer performance, oil chromatography and micro water testing
TOM-6000type The online monitoring system for transformer oil chromatography is used for online analysis and fault diagnosis of dissolved gases in power transformer oil, and is suitable forvariousVoltage level electricityOil fillingOil immersed high-voltage equipment such as transformers, electric arc furnace transformers, reactors, and transformers.
TOM-6000type The online monitoring system for transformer oil chromatography canimplementAutomatic quantitative cycle cleaning, oil inlet, oil and gas separation, sample analysis, data processing, real-time alarm; Quickly monitor the content and growth rate of dissolved fault gases in the oil of oil immersed high-voltage power equipment such as transformers online, and use a fault diagnosis expert system to early predict equipment fault hidden danger information, avoid equipment accidents, reduce significant losses, and improve the reliability of equipment operation. As a new generation product in the field of oil chromatography online monitoring, this system will achieve online remote monitoring for power transformersDGAAnalyzing and providing stable and reliable solutions is a powerful guarantee for the implementation of the power system state maintenance system.
TOM-6000typeThe system is created by combining our company's nearly 20 years of successful experience in the operation of automatic full degassing equipment for power chromatography, and summarizing the advantages and disadvantages of online oil chromatography monitoring at home and abroad. This system maintains the advantages of stability, reliability, accuracy, and other aspects that our company's products have always had:
♦online detectionH2TheCOTheCO2TheCH4TheC2H4TheC2H2TheC2H6TheH20(optional)Concentration and growth rate;
♦Quantitative cleaning cycle sampling method, which truly reflects the dissolved gas state in transformer oil;
♦Oil and gas separation is safe, reliable, and non polluting,Users can choose whether to discharge or not to discharge transformer oil;
♦Using specialized composite chromatography columns to improve the separation of gas components;
♦Adopting imported specially designed detectors to improve the detection sensitivity of hydrocarbon gases;
♦High stability and high-precision gas detection technology, with an error range of± 10%;
♦Mature and reliable communication methods, using standard network protocols, supporting remote data transmission;
♦High reliability of data collection, using oversampling technologyΔ-∑Analog to digital converter,24Bit resolution, automatic calibration;
♦Diverse data display and query methods, providing reports and trend charts, with a historical data storage lifespan of10Year;
♦Strong adaptability to the environment, successfully applied in high-altitude, high temperature, high humidity, and high-altitude areas;
♦High anti-interference performance and electromagnetic compatibility meet the requirementsGB/T17626andIEC61000Standard;
♦Provide two-level alarm function, and the alarm signal can be transmitted remotely;
♦Open database that can be connected to the local area network of the power system;
In addition,TOM-6000typeThe system adopts a modular design, and the application of high-performance embedded processors makes the chromatography online monitoring system more stable and reliable, and has the following characteristics:
♦Faster analysis cycle, * small monitoring cycle is40-60Minutes, can be set by users themselves, recommendedinspection cyclefor24Check once per hour;
♦Fast oil and gas separation speed, only requires10minuteDuo ZhongLeft and right, using special environmental adaptation techniques to eliminate the impact of temperature and humidity changes on gas distribution coefficients;
♦The analyzed oil sample is treated with degassing and buffering techniques to eliminate bubbles in the oil sample injected back into the transformer body. The multi-layer isolated oil injection (return oil) technology ensures that the carrier gas will not be carried into the transformer body;
♦ C2H2*The detection limit can reach0.1-0.5 μ L/L;
♦Adopting dual loop multi-mode constant temperature control, the temperature control accuracy reaches± 0.1 ℃The equipment is equipped with automatic constant temperature industrial air conditioning;
♦Adopting an embedded processor control system, it integrates multiple functions such as oil and gas separation, data acquisition, chromatographic analysis, concentration calculation, data alarm, and equipment status monitoring, without data loss, greatly improving the reliability and stability of the system;
♦The functional interface circuit adopts optocoupler isolation design to further improve the anti-interference performance of the system;
♦adoptEthernet modeIt can achieve full digital, remote data transmission, control, and parameter setting;
♦Strengthen the system fault diagnosis function, provide improved three ratio method, David's triangle method, and cube diagram method, and provide diagnostic results;
♦Strengthen system self inspection, add remote maintenance function, and provide equipment abnormal event alarm;
♦support61850communicationProtocol, providing networking function for similar monitoring devices, which can achieve centralized remote diagnosis in a certain area;
♦system architectureadopt19”Standard chassis and highly integrated modular design, structureCompact, easy to install and maintain, user-friendly operation;
♦High scalability and easy integration with other monitoring devices;
♦No steel cylinder design, no need to replace the carrier gas every year, greatly reducing the amount of after-sales maintenance, and there is no high-voltage container next to the transformer, ensuring the safety of the equipment and no safety hazards.
| serial number | Technical parameter name | Provide value | |
| 1 | System Model | TOM-6000 | |
| 2 | Working environment temperature | -40℃~+70℃ | |
| 3 | Working environment humidity | relative humidity5~95%(There should be no condensation or freezing inside the device) | |
| 4 | atmospheric pressure | 70kPa~110kPa | |
| 5 | working power supply | AC 220 V±10%,50Hz | |
| 6 | Monitoring components | H2TheCOTheCO2TheCH4TheC2H4TheC2H2The C2H6TheH20(Optional) etc7Gas components andMicro water, relative growth rate, and absolute growth rate; Micro water monitoring in oil is optional | |
| 7 | Analysis and diagnostic function | Analyze and diagnose monitoring data by improving the three ratio method, David's triangle method, and cube plot method, and provide original spectra | |
| 8 | *Small detection cycle | 40-60Minutes, can be set by the user themselves, default24hour | |
| 9 | Sampling method | Cyclic sampling, safely and accurately reflecting the gas composition in transformers | |
| 10 | Oil and gas separation method | Vacuum degassing method | |
| 11 | Data storage lifespan | ≥ 10year | |
| 12 | Equipped with gas carrying capacity | Gas source generator | |
| 13 | Monitoring gas | measurement range | *Testing |
| 1) | H2 | 2 ~2000 µ l/l | 2µ l/l |
| 2) | CO | 5 ~ 20000 µ l/l | 5 µ l/l |
| 3) | CH4 | 0.2 ~2000 µ l/l | 0.1-0.5 µ l/l |
| 4) | C2H4 | 0.2 ~2000 µ l/l | 0.1-0.5 µ l/l |
| 5) | C2H6 | 0.2 ~2000 µ l/l | 0.1 -0.5µ l/l |
| 6) | C2H2 | 0.2 ~ 2000 µ l/l | 0.1-0.5 µ l/l |
| 7) | C02 | 25 ~ 20000 µ l/l | 25 µ l/l |
| 8) | H2O(Optional) | 1~800 µ l/l | |
| 9) | Total hydrocarbons | 1~8000 µ l/l | |
| 10) | Total gas content (optional) | 0.2~15% | |
| 14 | Stability (measurement deviation) | The deviation of monitoring results for the same oil sample under the same experimental conditions shall not exceed±5%(Medium concentration) | |
| 15 | Electrostatic discharge immunity | 4Level,± 8kV-± 15kV | |
| 16 | Electrical fast transient burst immunity | 4Level,± 4kV | |
| 17 | Surge (impact) immunity | 4Level,± 4kV | |
| 18 | Seismic resistance: Seismic waves are sine waves Duration: Three cycles, safety factor1.67 | seismic intensity9Region: 地面水平加速度0.4gGround vertical acceleration0.2g | |
| seismic intensity8Region: 地面水平加速度0.25gGround vertical acceleration0.125g | |||
| seismic intensity7Region: 地面水平加速度0.2gGround vertical acceleration0.1g | |||
| 19 | Storage and transportation extreme environmental temperature | -40 ℃~+80 ℃ | |
| 20 | Protective performance of the shell | Outdoor installation components (this system and communication control unit)IP56 | |
| 21 | Overall dimensions | Width 535mm ×deep600mm ×tall1100mm | |
| 22 | Total weight | 125kg | |
| 23 | Basic dimensions | Length 800mm x Width 600mm xground elevation200mm左右 | |
Update time: September 4, 2020 16:48:45