Welcome Customer !

Membership

Help

Xi'an Shengli Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Xi'an Shengli Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    25th Floor, Building G, Wangzuo Modern City, No. 35 Tangyan Road, High tech Zone, Xi'an City, Shaanxi Province

Contact Now

VICTOR 01S Temperature Signal Generator

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

VICTOR 01S temperature signal generator (hereinafter referred to as the signal generator) is a handheld portable instrument powered by batteries, capable of outputting electrical and physical parameters. Can be used to simulate output DC voltage, resistance, thermocouple, and thermistor.

Product Details

VICTOR 01S Temperature Signal Generator(hereinafter referred to as signal generator) is a handheld portable instrument powered by batteries, capable of outputting electrical and physical parameters. Can be used to simulate output DC voltage, resistance, thermocouple, and thermistor.

VICTOR 01STemperature signal generator

1 Basic characteristics of the product

1. Analog output characteristics

l basicfunction

DC voltageDCVResistanceOHMThermocoupleTCThermal resistanceRTD

l Highest outputprecision0.05%The output is displayed as5Position.

l Can be manually pressedBit increase/decrease output setting.

l OHMExcitation current hasH / LTwo settings.

l The output temperature value and corresponding temperature signal are displayed on the same screen.

2. Built in high-precision temperature sensor with high-precision cold end compensation.

The compensation method for the cold end of the thermocouple can be set, including:manualcompensation, AutomaticcompensationcompensationConnection disconnection, etc.

3. Maintain the settings function, including:

Automatic shutdown, backlight, flashlight, etc

4. other

l segment codeLCDScreen display, white backlight.

l LEDFlashlight illumination.

l 3section5Powered by alkaline batteries, the battery compartment door allows for easy battery replacement and low battery detection.

l Compact, sturdy, reliable, suitable for on-site use, and affordable.

l User selectable high suction magnetic strap.

IIBasic functions and performance (technical indicators) of the product

Analog output function[Applicable toWithin one year after calibration23±52070%RHAccuracy%set value+Character)]

output function

range

output range

resolution

accuracy

remark

DC voltage

DCV

100mV

-10.000mV~110.00mV

0.01mV

0.05%+0.03mV

Maximum output current:0.5mA

1V

-0.1000V~1.1000V

0.0001V

0.05%+0.3mV

Maximum output current2mA

ohm

OHM

400Ω

0~400.0Ω

0.1Ω

0.05%+0.2Ω

The excitation current is±0.1±5mA

Maximum output voltage2V

The excitation current is±0.10.5mAWhen, add0.3ΩAdditional error

Accuracy does not include lead resistance

4KΩ

0~4.000KΩ

0.05%+2Ω

thermocouple

TC

R

0°C1767°C

1°C

0.05%+3(Less than or equal to)100°C

0.05%+2(Greater than)100°C

adoptITS-90Temperature scale

Accuracy does not include errors in cold end compensation

Accuracy does not include the inaccuracy of sensors

Accuracy does not include the influence of thermoelectric potential

The material corresponding to the left division mark is as follows:

R: platinum-rhodium13-platinum

S: platinum-rhodium10-platinum

K: nickel-chromium-Nickel silicon

E: nickel-chromium-Copper nickel (constantan)

J: iron-Copper nickel (constantan)

T: copper-Copper nickel (constantan)

N: Nickel chromium silicon-Nickel silicon

B: platinum-rhodium30-platinum

A: Tungsten rhenium 5 -Tungsten rhenium 20

C: Tungsten rhenium 5 -Tungsten rhenium 26

D: Tungsten rhenium 3 -Tungsten rhenium 25

S

0°C1767°C

K

-200.0°C1372.0°C

0.1°C

0.05%+2(Less than or equal to)-100°C

0.05%+1(Greater than)-100°C

E

-200.0°C1000.0°C

J

-200.0°C1200.0°C

T

-250.0°C400.0°C

N

-200.0°C1300.0°C

B

600°C1820°C

1°C

0.05%+3

A

0°C2500°C

1°C

C

0°C2310°C

1°C

D

0°C2310°C

1°C

thermal resistor

RTD

Pt100

385

-200.0°C800.0°C

0.1°C

0.05%+0.6

adoptPt385)Temperature scale

The excitation current is±0.1±5mA

Maximum output voltage2V

The excitation current is±0.10.5mAWhen, add0.3ΩAdditional error

Accuracy does not include lead resistance

Accuracy does not include the influence of thermoelectric potential

Pt200

385

-200.0°C630.0°C

Pt500

385

-200.0°C630.0°C

Pt1000

385

-200.0°C630.0°C

Cu50

-50.0°C150.0°C

Other features:

l Uncertainty includes standard uncertainty, lag, nonlinearity, repeatability, and typical long-term stability during the mentioned period(K2).

l Maximum applied voltage at the output end: approximately30Vpk Maximum applied current at the output end: approximately25mA

l Load characteristics: capacitive load≥0.01uFDCV/OHM/TC/RTD/FREQ); inductive load≥0.01uF 100uHDCA

Output load impact DCmV0.001%Full scale+ 1 nV/ mA DCV0.001%Full scale+ 1 nV/ mA

l Internal temperature compensation sensorRJCTemperature measurement range -1050°CIn18 to 28°CTemperature measurement accuracy±0. 5Other temperature measurement accuracies±1Cold end compensation time10S/Next time.

l Temperature coefficient:0.1 ×Basic accuracy/ (Temperature range)<18or>28


IIIGeneral characteristics of the product

l Working temperature and humidity:0 to 50ºC ≤80%RHNo condensation;40 to 50ºC ≤70%RH.

l Storage temperature and humidity:-25 to 60ºC ≤90%RHNo condensation.

l Electrical safety:EN61010-12001

Voltage endurance:Between the terminal and the casingAC3540V(50/60Hz)5second.

Insulation impedance:Between the terminal and the casingDC1000V /100MΩOr larger.

l Electromagnetic compatibility(EMC):EN61326-12006

Meets performance criteria2Temporary reduction or loss of functionality and performance, but capable of self recovery.

l Protection levelIP40.

l Vibration and Falling:IEC 60068-2-642008TheIEC 60068-2-322008

Random,2g5500Hz1Rice drop test.

l CEauthentication.

l Quality standards: in accordance withTUV ISO 9001Development, design, and manufacturing.

l Calibration cycle and preheating time:

To ensure the accuracy of this table, its calibration cycle is one year

The startup preheating time is greater than30minute

l Instrument display and buttons

segment codeLCDDisplay, white backlight

Adopting silicone rubber buttons

l Instrument power supply

3section5Powered by alkaline batteries

l Dimensions and Weight