Special gas chromatograph for detection and analysis of residual free toluene diisopropyl ester in coatings. The gas chromatograph is usedThe capillary column, hydrogen flame ionization detector, and trichlorobenzene as the internal standard have improved the quantitative analysis method of TDI monomers in polyurethane curing agents. This method achieves better separation between the internal standard and TDI at low temperatures, while reducing the occurrence of side reactions. The operation is simple and the analysis time is short, especially for samples with low TDI content, the precision and accuracy are more ideal than previous methods.
Usage: used as raw material of polyurethane soft foam, paint, rubber, fiber and adhesive.

Performance Characteristics
Injection port flow rate, chromatographic column carrier gas flow rate, detector gas flow rate, precision control
Multiple injection ports can be configured: packed column injection port (with spacer blowing, can be connected to large-diameter capillary column), splitter/Non split capillary injection port, program-controlled cold column head injection port, volatile component series connection injection port (specially equipped with sample pretreatment devices such as headspace/sweep capture/thermal desorption);
Detector Design for Industry *
The amplification plate with special ceramic treatment is stable during humid seasons, automatically ignites, and has automatic protection against hydrogen leakage, making it safe and reliable.
Precise control program temperature rise and furnace temperature, precise furnace temperature tracking design
The internal control accuracy of the furnace is less than0.01℃; The temperature difference between internal points shall not exceed 1 ℃; Rapid heating and cooling, with a programmed heating rate of 120 ℃/min; Balance time of 10 seconds; Cooling time (300 ℃ to 50 ℃) for 6 minutes; The accuracy of temperature control (with a difference of less than 0.1 ℃ from the actual temperature).
Fully imported valve configuration system
*More equipped8 valves (four-way valve, six way valve, ten way valve, and liquid injection valve optional); Automatic control and sequential operation; 0 leakage blowing technology; High speed switching solenoid valve has a long service life (1 million times, 10mS).
Separated columns oven
In a multi column chromatography system, the operating temperatures of different columns can be set separately to achieve the desired temperature for each columnpremiumSeparation effect;
Convenient implementation of pneumatic cutting technology
It can achieve multidimensional chromatography function to separate and analyze complex samples, and can realize the blowback function of the chromatography column to save analysis time and cycle;
technical indicators
| Column temperature box | |
| Temperature control range | Room temperature+5 ℃~450 ℃; |
| Temperature setting accuracy | 0.1℃ |
| Program heating speed | 60℃/min |
| Cheng Sheng's order | 8th order program temperature rise |
| Cheng Sheng rate | 0.1~120 ℃/min (incremental 0.1 ℃) |
| *Running time | 999.99 minutes |
| Runable column loss compensation (dual channel) | |
| heating zone | |
| 6 independent control heating zones (excluding furnace temperature control, two injection ports, two detectors, and two auxiliary heating zones) | |
| Auxiliary heating zone operating temperature | 300℃ |
| detector | |
| Hydrogen flame ionization detector FID | |
| Operating temperature | 450℃ |
| detection limit | ≤2.5pgC/s [n-C16] |
| Dynamic linear range | ≥107(±10%) |
| Data collection frequency | 100Hz |
| Compatible with packed columns and capillary columns | |
| Thermal conductivity detector TCD | |
| Operating temperature | 400℃ |
| detection limit | <400pg propane/mL, helium |
| Dynamic linear range | 105(±5%) |
| Data collection frequency | 100Hz |
| Single filament micro pool design; Compatible with packed columns and capillary columns | |
| Flame photometric detector FPD | |
| Operating temperature | 250℃ |
| detection limit | <4pgC/s(P),<1pgC/s(S) |
| selectivity | 105gS/gC,106gP/gC |
| Dynamic linear range | >103S,>104P |
| Compatible with packed columns and capillary columns | |
| Electronic Capture Detector (ECD) | |
| Operating temperature | 400℃ |
| Detector compensation gas type | 5% methane/argon or nitrogen |
| detection limit | <0.01Ppg/s lindane |
| Dynamic linear range | >5×105 |
| Data collection frequency | 100Hz |
| radioactive source | <12mCi 63Ni |
| Compatible with packed columns and capillary columns | |
| NPD nitrogen phosphorus detector | |
| Operating temperature | 450℃ |
| detection limit | <3pgC/s |
| Dynamic linear range | 105N,106P |
| Data collection frequency | 100Hz |
| *Small detection limit | <0.2pgN/s,<0.2pgP/s |
| Compatible with packed columns and capillary columns | |