E-mail
513687859@qq.com
-
Phone
18317070697
-
Address
No. 888 Siyi Road, Jiading District, Shanghai
Shanghai Kelute Technology Instrument Co., Ltd
513687859@qq.com
18317070697
No. 888 Siyi Road, Jiading District, Shanghai
1、 Product Introduction
Small formaldehyde emission detection chamberThe main parts include: insulation box, mirror stainless steel test chamber, clean constant temperature and humidity air supply system, air circulation device, air exchange device, test chamber temperature control unit, signal control and processing part (temperature, humidity, pressure, time, flow rate, replacement rate, etc.). The temperature regulating unit, circulating fan motor, etc. are placed in the jacket between the inner cavity of the test chamber and the insulation box to reduce the adsorption of formaldehyde and TVOC by the test chamber. All joint parts are sealed, and the test cabin door adopts a self sealing device to ensure positive pressure inside the test cabin and prevent the infiltration of surrounding air.
Small formaldehyde emission detection chamberUsing a touch control screen as the dialogue interface for human-machine operation devices is intuitive and convenient. Configure control software, in addition to the touch screen function, it also has remote control function, which can achieve system control, multi-stage program setting, dynamic data display and historical data playback, with one click trigger start mode, fault recording, alarm setting and other functions. Full protection devices and system safety operation protection devices make equipment operation more reliable and safe.
2、 Technical parameters
model |
KLT-J225 |
KLT-J1000 |
||
Nominal internal volume (liters) |
225(1±2%) |
1000(1±2%) |
||
|
internal dimensions (mm) |
W |
550 |
850 |
|
D |
600 |
1080 |
||
H |
680 |
1100 |
||
|
external dimensions (mm) |
W |
1100 |
1500 |
|
D |
796 |
1300 |
||
H |
1520 |
1850 |
||
|
sex can |
temperature range |
15~30 ℃ |
||
humidity range |
35~70 % RH |
|||
temperature deviation |
≤ ±0.5 ℃ |
|||
humidity deviation |
≤ ± 2% RH |
|||
Temperature Uniformity |
≤±0.8 ℃ |
|||
humidity uniformity |
≤ ±2 % RH |
|||
temperature fluctuation |
≤ ±0.5℃ |
|||
Humidity fluctuation |
≤ ± 2% RH |
|||
Ventilation rate |
0-1.5 times/hour |
|||
sealing performance |
The air leakage rate inside the cabin is less than 5%. If the gas supply rate or pressure exceeds 1kpa, the gas leakage rate is less than 0.5% of the cabin capacity per minute |
|||
Central wind speed |
0.1-1.0m/s (continuously adjustable) |
|||
Relative positive pressure |
10±5pa |
|||
spike recovery rate |
>80% |
|||
Background value |
Formaldehyde: ≤ 0.006mg/m3 |
|||
Temperature control method |
Indirect temperature control method for water circulation |
|||
Humidity control method |
Dual directional adjustment method for dry gas and moisture ratio |
|||
|
material |
shell |
Q235A cold-rolled steel plate 1.5mm, surface electrostatic spraying, white |
||
inner box |
SUS304 mirror stainless steel 1.5mm (8k mirror) |
|||
adiabatic |
High density polyurethane foam+XPS |
|||
seal |
Silicone (food grade), polytetrafluoroethylene |
|||
|
operation control |
monitor |
7-inch color touch screen, resolution 800x480, remote control (optional) |
||
Automatically record projects |
Temperature, humidity, pressure (optional), flow rate (optional), operating time, fault record |
|||
Control method |
Temperature control: proportional, integral, derivative (P.I.D); System control: PLC+HMI |
|||
resolution |
Temperature: 0.1 ℃; Humidity: 0.1% RH |
|||
communication interface |
1 USB-A, 1 USB-B, 1 RS232, 1 RS485, 1 RJ-45 (optional) |
|||
Rough storage and recording function |
Memory, USB flash drive, SD card |
|||
Supplement water quality and cycle |
Distilled water; >30 days (continuous operation) |
|||
power supply |
AC380 (1 ± 10%) V (50 ± 0.5) Hz three-phase four wire+protective grounding |
|||
Installed capacity (Kw) |
2.5 |
3.0 |
||
Weight (Kg) |
280 |
320 |
||
Noise (dB) |
≤ 60dB |
|||
system protection |
High and low pressure protection, overcurrent protection of refrigeration system; Overtemperature protection; Motor overcurrent protection; Water shortage protection; Power supply under phase, phase sequence protection, etc. |
|||