Welcome Customer !

Membership

Help

Shanghai Kelute Technology Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Shanghai Kelute Technology Instrument Co., Ltd

  • E-mail

    513687859@qq.com

  • Phone

    18317070697

  • Address

    No. 888 Siyi Road, Jiading District, Shanghai

Contact Now

Small formaldehyde emission detection chamber

NegotiableUpdate on 12/31
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The small formaldehyde emission detection chamber adopts a touch control screen as the dialogue interface for human-machine operation equipment, which is intuitive and convenient. Configure control software, in addition to the touch screen function, it also has remote control function, which can achieve system control, multi-stage program setting, dynamic data display and historical data playback, with one click trigger start mode, fault recording, alarm setting and other functions. Full protection devices and system safety operation protection devices make equipment operation more reliable and safe.

Product Details

1、 Product Introduction

Small formaldehyde emission detection chamberThe main parts include: insulation box, mirror stainless steel test chamber, clean constant temperature and humidity air supply system, air circulation device, air exchange device, test chamber temperature control unit, signal control and processing part (temperature, humidity, pressure, time, flow rate, replacement rate, etc.). The temperature regulating unit, circulating fan motor, etc. are placed in the jacket between the inner cavity of the test chamber and the insulation box to reduce the adsorption of formaldehyde and TVOC by the test chamber. All joint parts are sealed, and the test cabin door adopts a self sealing device to ensure positive pressure inside the test cabin and prevent the infiltration of surrounding air.

Small formaldehyde emission detection chamberUsing a touch control screen as the dialogue interface for human-machine operation devices is intuitive and convenient. Configure control software, in addition to the touch screen function, it also has remote control function, which can achieve system control, multi-stage program setting, dynamic data display and historical data playback, with one click trigger start mode, fault recording, alarm setting and other functions. Full protection devices and system safety operation protection devices make equipment operation more reliable and safe.

2、 Technical parameters

model

KLT-J225

KLT-J1000

Nominal internal volume (liters)

225(1±2%)

1000(1±2%)

internal dimensions

(mm)

W

550

850

D

600

1080

H

680

1100

external dimensions

(mm)

W

1100

1500

D

796

1300

H

1520

1850

sex

can

temperature range

15~30 ℃

humidity range

35~70 % RH

temperature deviation

≤ ±0.5 ℃

humidity deviation

≤ ± 2% RH

Temperature Uniformity

≤±0.8 ℃

humidity uniformity

≤ ±2 % RH

temperature fluctuation

≤ ±0.5℃

Humidity fluctuation

≤ ± 2% RH

Ventilation rate

0-1.5 times/hour

sealing performance

The air leakage rate inside the cabin is less than 5%. If the gas supply rate or pressure exceeds 1kpa, the gas leakage rate is less than 0.5% of the cabin capacity per minute

Central wind speed

0.1-1.0m/s (continuously adjustable)

Relative positive pressure

10±5pa

spike recovery rate

>80%

Background value

Formaldehyde: ≤ 0.006mg/m3

Temperature control method

Indirect temperature control method for water circulation

Humidity control method

Dual directional adjustment method for dry gas and moisture ratio

material

shell

Q235A cold-rolled steel plate 1.5mm, surface electrostatic spraying, white

inner box

SUS304 mirror stainless steel 1.5mm (8k mirror)

adiabatic

High density polyurethane foam+XPS

seal

Silicone (food grade), polytetrafluoroethylene

operation control

monitor

7-inch color touch screen, resolution 800x480, remote control (optional)

Automatically record projects

Temperature, humidity, pressure (optional), flow rate (optional), operating time, fault record

Control method

Temperature control: proportional, integral, derivative (P.I.D); System control: PLC+HMI

resolution

Temperature: 0.1 ℃; Humidity: 0.1% RH

communication interface

1 USB-A, 1 USB-B, 1 RS232, 1 RS485, 1 RJ-45 (optional)

Rough storage and recording function

Memory, USB flash drive, SD card

Supplement water quality and cycle

Distilled water; >30 days (continuous operation)

power supply

AC380 (1 ± 10%) V (50 ± 0.5) Hz three-phase four wire+protective grounding

Installed capacity (Kw)

2.5

3.0

Weight (Kg)

280

320

Noise (dB)

≤ 60dB

system protection

High and low pressure protection, overcurrent protection of refrigeration system; Overtemperature protection; Motor overcurrent protection; Water shortage protection; Power supply under phase, phase sequence protection, etc.

小型甲醛释放量检测舱