E-mail
chocolat0306@163.com
-
Phone
13502125345
-
Address
Tianjin
DeKal Technology (Tianjin) Co., Ltd
chocolat0306@163.com
13502125345
Tianjin
TS102GXYSemiconductor cooling tableCan be used for optical equipment such as microscopes. The temperature control of the hot and cold table is based on Peltier semiconductor temperature control chips (TEC), which can reach -40 ℃ without the need for liquid nitrogen refrigeration consumables, making it suitable for long-term experiments. The cold and hot table uses standard glass slides measuring 25mm x 75mm and can be used for precise movement of samples under a microscope. The top cover and body of TS102GXY's hot stage form an airtight chamber, while TS102VXY's is a vacuum chamber that can be filled with protective gas or evacuated (depending on the model) to prevent the sample from frosting at negative temperatures.
Semiconductor cooling tableFeatures:
Suitable for optical equipment such as microscopes
TEC semiconductor temperature control chip, no need for liquid nitrogen refrigeration consumables during cooling, suitable for long-term experiments
-Programmable temperature control from 40 ℃ to 120 ℃ (no refrigeration consumables required)
Suitable for 25 mm x 75 mm standard glass slides
Differential moving ruler for moving samples in the XY direction
An airtight chamber that can be filled with protective gas (there are also vacuum chamber models available)
Can be controlled from a thermostat or computer software, with software SDK available
Temperature control parameters:
Temperature range -20 ℃~120 ℃ standard
-40 ℃~120 ℃ optional
Heating block material: alumina
Sensor/Temperature Control Method 100 Ω Platinum RTD/PID Control
Maximum heating/cooling speed+60 ℃/min (at 37 ℃)
-20 ℃/min (at 37 ℃)
Minimum heating/cooling speed ± 0.01 ℃/min
Temperature resolution 0.01 ℃
Temperature stability ± 0.05 ℃
The software function can set temperature control rate, temperature control program, and record temperature control curve
Optical parameters:
Applicable optical path: transmission optical path and reflection optical path
Removable and replaceable window panels
Minimum working distance of objective lens 5.6 mm * WD in cross-sectional view
Minimum working distance of spotlight 13.6 mm * CWD in cross-sectional view
Transmitting hole with a diameter of 5 mm and a cross-sectional view with a diameter of VA
The observation window range of the upper cover is 27mm, with a maximum viewing angle of ± 60 ° * θ 1 in the cross-sectional view
The maximum viewing angle observed by the bottom window is ± 13 ° * θ 2 in the cross-sectional view
Window defrosting air blowing defrosting pipeline under negative temperature
Structural parameters:
Heating area/sample area 40mm x 40mm
Sample cavity height of 3.5 mm without inner cover
2.0 mm inner cover
*Maximum sample thickness=sample chamber height - slide thickness
Sample substrate defaults to 25 mm x 75 mm standard glass slide
*Can be replaced with other options according to user needs
Set out the horizontal layout, extract the upper cover, and then insert the sample
The sample XY ruler can move the sample under the microscope with a resolution of 10 μ m and a stroke of 10mm
The shell is cooled by circulating water to maintain the shell temperature near room temperature
Installation method: horizontal or vertical installation
台体尺寸/重量169 mm x 96 mm x 25 mm
800g(TS102GXY),900g(TS102VXY)
Configuration List:
Basic configuration: TS102GXY/TS1102VXY cold and hot table, mK2000B temperature controller
Shell circulating water cooling system
Optional accessories: Cold and hot table installation bracket, vacuum system (only for vacuum models)
Scope of application:
Used for matching with Instec hot and cold tables, Instec temperature control probe tables, Instec temperature control wafer clamps, Instec hot and cold plates, and Instec customized temperature control devices
Temperature control accessories series:
Installation bracket: used to fix the temperature control device on the user's equipment
MK2000B thermostat, including Instec APP temperature control software, temperature control device must be selected
Shell circulating water cooling system, Peltier type temperature control device must be selected
MITO series temperature controlled microscope camera, including control software
LWDC2 long working distance spotlight
Vacuum system: including vacuum pump and vacuum pipeline, used for vacuum type temperature control device
Shell circulating water cooling system
Used for cooling the casing/base of temperature control devices. When the temperature control device is heated/cooled, the temperature of the casing/base will be very hot/cold, which can harm surrounding personnel, equipment, and even the equipment itself. Using circulating water to keep the temperature of the casing around room temperature can effectively prevent this disaster.
MK2000B thermostat
Supports constant temperature, constant rate temperature change, pause, and programmed temperature control functions. It has the characteristics of independent multi segment PID control for hot and cold, and can store 4 sets of 20 segment calibration tables. It can be independently controlled or controlled through the Instec APP software
Temperature resolution ± 0.001 ℃ (thermistor), ± 0.01 ℃ (RTD), ± 0.1 ℃ (thermocouple)
Control interface USB virtual serial port optional other interfaces
Optional LVDC linear adjustable DC power supply for reducing electrical noise
Temperature control software Instec APP, can provide multilingual SDK
Installation bracket:
Customized for user devices, the hot table can be fixed horizontally/vertically, and can be used for user devices with vertical/horizontal light paths. Usually there are:
Circular ring type (for circular platforms), flat plate type (for square platforms)Carrier platform (used to replace equipment carrier platform), vertical (used for horizontal optical path)