HCS621GXYMicroscope hot and cold stageSpecially designed for microscopes/spectrometers. This hot and cold table can control the temperature within the range of -190 ℃~600 ℃, while allowing optical observation and sample gas environment control. The top cover and bottom shell of the hot stage form an airtight chamber, which can be filled with protective gases such as nitrogen to prevent the sample from frosting at negative temperatures or oxidizing at high temperatures. In addition, the cold and hot table is equipped with an XY sample differential movement ruler that can move samples from outside the sealed chamber. In addition, there is also a vacuum chamber model HCS421VXY available.
Microscope hot and cold stageFeatures
Suitable for microscopes/spectrometers
-190 ℃~600 ℃ programmable temperature control (negative temperature requires liquid nitrogen refrigeration system)
Heating zone with a diameter of 26 mm and a through-hole
Differential moving ruler for moving samples in the XY direction
An airtight chamber that can be filled with protective gas (there are also vacuum chamber models available)
Can be controlled from a thermostat or computer software, with software SDK available
Temperature control parameters
Temperature range -190 ℃~600 ℃ (negative temperature requires liquid nitrogen refrigeration system)
Heating block material silver
Sensor/Temperature Control Method 100 Ω Platinum RTD/PID Control
Maximum heating/cooling speed+150 ℃/min (at 100 ℃)
-50 ℃/min (at 100 ℃)
Minimum heating/cooling speed ± 0.01 ℃/min
Temperature resolution 0.01 ℃
Temperature stability ± 0.05 ℃ (>25 ℃), ± 0.1 ℃ (<25 ℃)
The software function can set temperature control rate, temperature control program, and record temperature control curve
optical parameters
Applicable optical path: transmission optical path and reflection optical path
Removable and replaceable window panels
Minimum working distance of objective lens 5 mm * WD in cross-sectional view
Minimum working distance of spotlight 11.5 mm * CWD in cross-sectional view
Transmitting hole with a diameter of 2 mm * in cross-sectional view, with a diameter of VA
The observation window range of the upper cover is 18mm, with a maximum viewing angle of ± 58 ° * θ 1 in the cross-sectional view
The observation window range of the bottom panel is 18mm, with a maximum viewing angle of ± 19 ° * θ 2 in the cross-sectional view
Window defrosting air blowing defrosting pipeline under negative temperature
structural parameters
Heating area/sample area Ø 26 mm
*When using an XY ruler, the sample area is determined by the sample substrate
Sample cavity height 2.5 mm
*Maximum sample thickness=sample cavity height - sample substrate thickness
The default sample substrate is a quartz crucible (inner diameter>9mm/thickness 0.5mm)
*Can be replaced with other options according to user needs
Set out the horizontal layout, extract the upper cover, and then insert the sample
The sample XY moving ruler can move the sample from outside the sealed chamber, with a resolution of 10 μ m and a stroke of 10mm
Atmosphere controlled airtight chamber, can be filled with protective gas
The cooling of the shell can be achieved by circulating water to maintain the shell temperature near room temperature
Installation method: horizontal or vertical installation
台体尺寸/重量 159.7 mm x 86 mm x 22 mm/500g
Configuration List
Basic configuration: HCS621GXY cold and hot table, mK2000B temperature controller
Optional accessories include cold and hot table installation bracket, liquid nitrogen refrigeration system, shell circulating water cooling system 、
Vacuum system (only for vacuum models)
Scope of Application
Used for pairing with Instec hot and cold tables, Instec temperature control probe tables, Instec temperature control wafer clamps, Instec hot and cold plates, and Instec customized temperature control devices.
Temperature control accessories series
Installation bracket: used to fix the temperature control device on the user's equipment
MK2000B thermostat, including Instec APP temperature control software, temperature control device must be selected
LN2-SYS liquid nitrogen refrigeration system: liquid nitrogen pump+liquid nitrogen tank+liquid nitrogen pipeline
Shell circulating water cooling system, Peltier type temperature control device must be selected
MITO series temperature controlled microscope camera, including control software
LWDC2 long working distance spotlight
Vacuum system: including vacuum pump and vacuum pipeline, used for vacuum type temperature control device
LN2-SYS liquid nitrogen refrigeration system
It is mainly divided into two parts: liquid nitrogen pump and liquid nitrogen tank. When in use, the temperature control device needs to be connected in series between the liquid nitrogen tank and the liquid nitrogen pump through a pipeline. The heating block of the temperature control device is embedded with a closed inlet and outlet pipeline. The liquid nitrogen pump is controlled by mK2000B to extract liquid nitrogen from the liquid nitrogen tank into the heating block of the temperature control device, achieving active cooling of the temperature control device.
Shell circulating water cooling system
Used for cooling the casing/base of temperature control devices. When the temperature control device is heated/cooled, the temperature of the casing/base will be very hot/cold, which can harm surrounding personnel, equipment, and even the equipment itself. Using circulating water to keep the temperature of the casing around room temperature can effectively prevent this disaster.
MK2000B thermostat
Supports constant temperature, constant rate temperature change, pause, and programmed temperature control functions. It has the characteristics of independent multi segment PID control for hot and cold, and can store 4 sets of 20 segment calibration tables. It can be independently controlled or controlled through the Instec APP software.
Temperature resolution ± 0.001 ℃ (thermistor), ± 0.01 ℃ (RTD), ± 0.1 ℃ (thermocouple)
Control interface USB virtual serial port optional other interfaces
Optional LVDC linear adjustable DC power supply for reducing electrical noise
Temperature control software Instec APP, can provide multilingual SDK
mounting bracket
Customized for user devices, the hot table can be fixed horizontally/vertically, and can be used for user devices with vertical/horizontal light paths. Usually there are:
Circular ring type (for circular platforms), flat plate type (for square platforms)
Load platform (used to replace equipment load platform), vertical (used for horizontal optical path).