Overview
The top cover and bottom shell of the microscope cold and hot stage form an airtight chamber, which can be filled with protective gases such as nitrogen to prevent the sample from frosting at negative temperatures or oxidizing at high temperatures. In addition, the cold and hot table is equipped with an XY sample differential movement ruler that can move samples from outside the sealed chamber.
Product Details

HCS621GXYMicroscope hot and cold stageSpecially designed for microscopes/spectrometers. This hot and cold table can control the temperature within the range of -190 ℃~600 ℃, while allowing optical observation and sample gas environment control. The top cover and bottom shell of the hot stage form an airtight chamber, which can be filled with protective gases such as nitrogen to prevent the sample from frosting at negative temperatures or oxidizing at high temperatures. In addition, the cold and hot table is equipped with an XY sample differential movement ruler that can move samples from outside the sealed chamber. In addition, there is also a vacuum chamber model HCS421VXY available.


Microscope hot and cold stageFeatures

Suitable for microscopes/spectrometers

-190 ℃~600 ℃ programmable temperature control (negative temperature requires liquid nitrogen refrigeration system)

Heating zone with a diameter of 26 mm and a through-hole

Differential moving ruler for moving samples in the XY direction

An airtight chamber that can be filled with protective gas (there are also vacuum chamber models available)

Can be controlled from a thermostat or computer software, with software SDK available

Temperature control parameters

Temperature range -190 ℃~600 ℃ (negative temperature requires liquid nitrogen refrigeration system)

Heating block material silver

Sensor/Temperature Control Method 100 Ω Platinum RTD/PID Control

Maximum heating/cooling speed+150 ℃/min (at 100 ℃)

-50 ℃/min (at 100 ℃)

Minimum heating/cooling speed ± 0.01 ℃/min

Temperature resolution 0.01 ℃

Temperature stability ± 0.05 ℃ (>25 ℃), ± 0.1 ℃ (<25 ℃)

The software function can set temperature control rate, temperature control program, and record temperature control curve

optical parameters

Applicable optical path: transmission optical path and reflection optical path

Removable and replaceable window panels

Minimum working distance of objective lens 5 mm * WD in cross-sectional view

Minimum working distance of spotlight 11.5 mm * CWD in cross-sectional view

Transmitting hole with a diameter of 2 mm * in cross-sectional view, with a diameter of VA

The observation window range of the upper cover is 18mm, with a maximum viewing angle of ± 58 ° * θ 1 in the cross-sectional view

The observation window range of the bottom panel is 18mm, with a maximum viewing angle of ± 19 ° * θ 2 in the cross-sectional view

Window defrosting air blowing defrosting pipeline under negative temperature

structural parameters

Heating area/sample area Ø 26 mm

*When using an XY ruler, the sample area is determined by the sample substrate

Sample cavity height 2.5 mm

*Maximum sample thickness=sample cavity height - sample substrate thickness

The default sample substrate is a quartz crucible (inner diameter>9mm/thickness 0.5mm)

*Can be replaced with other options according to user needs

Set out the horizontal layout, extract the upper cover, and then insert the sample

The sample XY moving ruler can move the sample from outside the sealed chamber, with a resolution of 10 μ m and a stroke of 10mm

Atmosphere controlled airtight chamber, can be filled with protective gas

The cooling of the shell can be achieved by circulating water to maintain the shell temperature near room temperature

Installation method: horizontal or vertical installation

台体尺寸/重量 159.7 mm x 86 mm x 22 mm/500g

Configuration List

Basic configuration: HCS621GXY cold and hot table, mK2000B temperature controller

Optional accessories include cold and hot table installation bracket, liquid nitrogen refrigeration system, shell circulating water cooling system 、

Vacuum system (only for vacuum models)

Scope of Application

Used for pairing with Instec hot and cold tables, Instec temperature control probe tables, Instec temperature control wafer clamps, Instec hot and cold plates, and Instec customized temperature control devices.

Temperature control accessories series

Installation bracket: used to fix the temperature control device on the user's equipment

MK2000B thermostat, including Instec APP temperature control software, temperature control device must be selected

LN2-SYS liquid nitrogen refrigeration system: liquid nitrogen pump+liquid nitrogen tank+liquid nitrogen pipeline

Shell circulating water cooling system, Peltier type temperature control device must be selected

MITO series temperature controlled microscope camera, including control software

LWDC2 long working distance spotlight

Vacuum system: including vacuum pump and vacuum pipeline, used for vacuum type temperature control device

LN2-SYS liquid nitrogen refrigeration system

It is mainly divided into two parts: liquid nitrogen pump and liquid nitrogen tank. When in use, the temperature control device needs to be connected in series between the liquid nitrogen tank and the liquid nitrogen pump through a pipeline. The heating block of the temperature control device is embedded with a closed inlet and outlet pipeline. The liquid nitrogen pump is controlled by mK2000B to extract liquid nitrogen from the liquid nitrogen tank into the heating block of the temperature control device, achieving active cooling of the temperature control device.

Shell circulating water cooling system

Used for cooling the casing/base of temperature control devices. When the temperature control device is heated/cooled, the temperature of the casing/base will be very hot/cold, which can harm surrounding personnel, equipment, and even the equipment itself. Using circulating water to keep the temperature of the casing around room temperature can effectively prevent this disaster.

MK2000B thermostat

Supports constant temperature, constant rate temperature change, pause, and programmed temperature control functions. It has the characteristics of independent multi segment PID control for hot and cold, and can store 4 sets of 20 segment calibration tables. It can be independently controlled or controlled through the Instec APP software.

Temperature resolution ± 0.001 ℃ (thermistor), ± 0.01 ℃ (RTD), ± 0.1 ℃ (thermocouple)

Control interface USB virtual serial port optional other interfaces

Optional LVDC linear adjustable DC power supply for reducing electrical noise

Temperature control software Instec APP, can provide multilingual SDK

mounting bracket

Customized for user devices, the hot table can be fixed horizontally/vertically, and can be used for user devices with vertical/horizontal light paths. Usually there are:

Circular ring type (for circular platforms), flat plate type (for square platforms)

Load platform (used to replace equipment load platform), vertical (used for horizontal optical path).