E-mail
chocolat0306@163.com
-
Phone
13502125345
-
Address
Tianjin
DeKal Technology (Tianjin) Co., Ltd
chocolat0306@163.com
13502125345
Tianjin
HS1500GMicroscope high-temperature hot stageSpecially designed for ultra-high temperature applications on microscopes/spectrometers, it can be used in fields such as ceramics, metallurgy, geology, and high-temperature materials. Sample power leads can be installed, and sample areas can be customized. This high-temperature hot bench can control the temperature within the range of 30 ℃~1500 ℃, while allowing optical observation and sample gas environment control. The hot table window cover and the table body form an airtight chamber, and the sample area is offset from the center of the window. This allows for the filling of protective gases such as nitrogen to prevent the sample from reacting at high temperatures, and also allows for the removal of volatile substances on the window by rotating it.
Microscope high-temperature hot stageFeatures:
Suitable for ultra-high temperature applications of microscopes/spectrometers
Programmable temperature control from 30 ℃ to 1500 ℃
Heating zone with a diameter of 7.5 mm
Sample area - eccentric design of the window, rotatable window to remove high temperature volatiles
An airtight chamber that can be filled with protective gas
Can be controlled from a thermostat or computer software, with software SDK available
Height increasing cover
Ultra high temperature applications suitable for infrared devices
Increase the distance between the heating zone and the infrared glass to prevent damage
Temperature control parameters
Temperature range 30 ℃~1500 ℃
Heating block material: High temperature resistant ceramic
Sensor/Temperature Control Method S-type Thermocouple/PID Control
Maximum heating+100 ℃/min (when<800 ℃); +When 20 ℃>800 ℃
Minimum heating ± 0.5 ℃/min
Temperature resolution 0.1 ℃
Temperature stability ± 1 ℃
The software function can set temperature control rate, temperature control program, and record temperature control curve
optical parameters
Applicable optical path: transmission optical path and reflection optical path
Removable and replaceable window panels
Minimum working distance of objective lens 6.3 mm (standard) 11.7 mm (height increasing cover) * WD in cross-sectional view
Minimum working distance of spotlight 13.3 mm * CWD in cross-sectional view
Transparent hole with a diameter of 2 mm and a cross-sectional view with a diameter of VA
The observation window range of the upper cover is 50mm, with a maximum viewing angle of ± 45 ° (standard)
The window range is Φ 16mm, with a maximum viewing angle of ± 34 ° (height increase cover) * θ 1 in the cross-sectional view
The observation window range of the bottom panel is Φ 16mm, with a maximum viewing angle of ± 19 ° * θ 2 in the cross-sectional view
Cooling of microscope by blowing air at high temperature
structural parameters
Heating area/sample area with a diameter of 7.5 mm
Sample cavity height 3.5 mm
*Maximum sample thickness=sample cavity height - sample substrate thickness
The default sample substrate is a quartz crucible (Φ 6 mmx1 mm)
Adjustable pressure window cover on top, balancing airtightness and window rotation
Atmosphere controlled airtight chamber, can be filled with protective gas
The shell is cooled by circulating water to maintain the shell temperature near room temperature
Installation method: horizontal or vertical installation
台体尺寸/重量 141 mm x 62 mm x 25.3 mm/1350g
Configuration List
Basic configuration: HS1500G high-temperature hot table, mK2000B temperature controller, shell circulating water cooling system
Optional accessories: Cold and hot table installation bracket, vacuum system (only for vacuum models), sample electrical lead wire
Scope of Application
Used for pairing with Instec hot and cold tables, Instec temperature control probe tables, Instec temperature control wafer clamps, Instec hot and cold plates, and Instec customized temperature control devices.
Temperature control accessories series
Installation bracket: used to fix the temperature control device on the user's equipment
MK2000B thermostat, including Instec APP temperature control software, temperature control device must be selected
Shell circulating water cooling system, Peltier type temperature control device must be selected
MITO series temperature controlled microscope camera, including control software
LWDC2 long working distance spotlight
Vacuum system: including vacuum pump and vacuum pipeline, used for vacuum type temperature control device
Shell circulating water cooling system
Used for cooling the casing/base of temperature control devices. When the temperature control device is heated/cooled, the temperature of the casing/base will be very hot/cold, which can harm surrounding personnel, equipment, and even the equipment itself. Using circulating water to keep the temperature of the casing around room temperature can effectively prevent this disaster.
MK2000B thermostat
Supports constant temperature, constant rate temperature change, pause, and programmed temperature control functions. It has the characteristics of independent multi segment PID control for hot and cold, and can store 4 sets of 20 segment calibration tables. It can be independently controlled or controlled through the Instec APP software.
Temperature resolution ± 0.001 ℃ (thermistor), ± 0.01 ℃ (RTD), ± 0.1 ℃ (thermocouple)
Control interface USB virtual serial port optional other interfaces
Optional LVDC linear adjustable DC power supply for reducing electrical noise
Temperature control software Instec APP, can provide multilingual SDK
mounting bracket
Customized for user devices, the hot table can be fixed horizontally/vertically, and can be used for user devices with vertical/horizontal light paths. Usually there are:
Circular ring type (for circular platforms), flat plate type (for square platforms)
Load platform (used to replace equipment load platform), vertical (used for horizontal optical path).