Welcome Customer !

Membership

Help

Beijing Purui Analytical Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Beijing Purui Analytical Instrument Co., Ltd

  • E-mail

  • Phone

    13701307156

  • Address

    225, 2nd Floor, Qingshang, Qinghe Xiaoying, Haidian District, Beijing

Contact Now

Puri GC-9280 high-end intelligent gas chromatograph manufacturer price fully electronic flow EPC control

NegotiableUpdate on 02/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The GC-9280 high-end intelligent gas chromatograph (fully electronic flow EPC control) is a mid to high end gas chromatograph with fully electronic flow control independently developed and produced by Purui Instrument for many years. We not only provide EPC modules as standard in the injection port, but also in various detector units. The fully automatic gas flow control system can comprehensively achieve efficient and intelligent analysis of GC, ensuring the repeatability and stability of gas phase analysis; Flexible and rich hardware expansion performance comprehensively meets the analysis needs of various industries.
Product Details
Detailed content

high-endintelligent typegas chromatographFull electronic trafficEPCcontrol

QQ图片20160304165022

GC-9280High end gas chromatographintelligent typegas chromatographFull electronic trafficEPCcontrolyesPurui InstrumentA mid to high end gas chromatograph with fully electronic flow control that has been independently developed and produced for many years.

We not only come standard with the injection portThe EPC module is also standard in various detector units, and the fully automatic gas flow control system can comprehensively achieve efficient and intelligent analysis of GC, ensuring the repeatability and stability of gas phase analysisFlexible and rich hardware expansion performance comprehensively meets the analysis needs of various industries.

Having a high-precision and stable gas path control system and detector module is a guarantee for reliable analysis!

The GC-9280 gas chromatograph comes standard with an AEFC module, which is installed in all gas control units of the injection port, detector, and auxiliary gas path to ensure perfect GC analysis!

(1) Microchannel gas path integrated board

(2) Equipped with imported proportional valve and pressure sensor

(3) Temperature compensation function ensures the accuracy and stability of flow rate

(4) Hydrogen leakage protection function

The GC-9280 gas chromatography system can be equipped with multiple detectors to meet the analysis needs of different fields: hydrogen flame ionization detector, thermal conductivity detector, electron capture detector, flame photometric detector, nitrogen phosphorus detector, photoionization detector, argon ionization detector, and helium ionization detector

Hydrogen flame ionization detector (FID)

1) The signal amplification board has undergone special processing and remains stable in harsh environments

2) Automatic ignition, hydrogen leakage protection function

3) Baseline noise, baseline drift, detection limit

Baseline noise: ≤ 5 × 10-14A;

Baseline drift: ≤ 3 × 10-13A/30min;

Detection limit: ≤ 2.5 × 10-12G c/s (n-hexadecane).

Thermal conductivity detector (TCD)

1) Suitable for filling columns and capillary columns

2) Single filament micro pool design, small dead volume, short equilibrium time

3) Baseline noise, baseline drift, sensitivity

Baseline noise: ≤ 0.1 mV;

Baseline drift: ≤ 0.2mV/30 min;

Sensitivity: ≥ 2500 mV · ml/mg (benzene, helium as carrier gas);

Detection limit: ≤ 3000 pg/ml (benzene, helium as carrier gas).

Electron Capture Detector (ECD)

1) Small volume micro pool design, stable and efficient

2) Safer and more sensitive, with only 8mCi ultra-low radiation but high response value

3) Anode blowing effectively avoids cross contamination between samples and has high repeatability

4) Baseline noise, baseline drift, detection limit

Baseline noise: ≤ 0.2 mV;

Baseline drift: ≤ 0.5 mV/30 min;

Detection limit: ≤ 9 × 10-15G/ml (hexachlorocyclohexane).

Flame photometric detector (FPD)

1) Unique local cooling technology to increase usage temperature

2) There is no cold spot for organophosphate pesticides

3) The internal pipeline is fully inert to ensure zero adsorption of the sample

4) Baseline noise, baseline drift, detection limit

Baseline noise: ≤ 4.0 × 10-12A;

Baseline drift: ≤ 4.0 × 10-11A/30 min;

Detection limit: ≤ 2 × 10-11G/s (sulfur); ≤2×10-13G/s (phosphorus) (standard substance: methyl parathion).

Simplified software platform

(1) It can quickly set various parameters such as front and rear injection ports, front and rear detectors, column temperature box heating program, chromatographic column conditions, and valve events

(2) The interface displays real-time data, allowing you to control the status of GC key components at any time

(3) Double click automatic recognition of chromatographic peak retention time, multispectral comparison and repeatability analysis, advanced data processing, flexible and rich report editing and other powerful application functions meet your various needs for experimental data analysis

We strictly select*premiumComponent suppliers ensure the complete setinstrumentExcellent and stable handling performance, reducing the user's failure rate to a certain extent, ensuring a perfect user experience.

At the same time, we also provide a series of value-added services for domestic customers, including imported GC modification, maintenance, and customer training.

Update time: September 1, 2020 8:53:10