DZB-718L typePortable multi parameter analyzer
● Built in Bluetooth, supports wireless transmission
Technical parameters:
model |
DZB-718L |
|
Instrument level |
PH/pX: 0.001 level Conductivity: Level 0.5 |
|
electric potential |
scope |
(-2000.00~2000.00)mV |
minimum resolution |
0.01 mV |
|
Electronic unit indication error |
± 0.03% or ± 0.1mV |
|
pH |
scope |
(-2.000~20.000)pH |
minimum resolution |
0.001 pH |
|
Electronic unit indication error |
±0.002pH |
|
pX |
scope |
(-2.000~20.000)pX |
minimum resolution |
0.001 pX |
|
Electronic unit indication error |
±0.002pX |
|
ion concentration |
scope |
( 1.000e-9~9.999e+9) Unit:mol/L、mmol/L、g/L、mg/L、μg/L、ppm、ppb |
minimum resolution |
Four significant digits (represented by Scientific notation) |
|
Electronic unit indication error |
±0.3% |
|
conductivity |
scope |
0.000μS/cm~3000mS/cm |
minimum resolution |
0.001μS/cm |
|
Electronic unit reference error |
±0.5%FS |
|
resistivity |
scope |
5.00Ω.cm~100.0MΩ.cm |
minimum resolution |
0.01 Omega cm |
|
Electronic unit reference error |
±0.5%FS |
|
TDS |
scope |
0.000 mg/L~1000g/L |
minimum resolution |
0.001mg/L |
|
Electronic unit reference error |
±0.5%FS |
|
salinity |
scope |
(0.00~8.00)% |
minimum resolution |
0.01% |
|
Electronic unit reference error |
±0.1% |
|
ash content |
Measurement method for ash content of white sugar, Ash of White Suga |
support |
Measurement method for ash content of fruit glucose syrup, Ash Content of HFCS |
support |
|
dissolved oxygen |
scope |
Electronic unit: (0.00~99.99) mg/L Supporting range: (0.00~50.00) mg/L |
minimum resolution |
0.01mg/L |
|
Electronic unit indication error |
(0.00~50.00)mg/L,±0.10mg/L (50.0~99.99)mg/L,±0.50mg/L |
|
Instrument indication error |
≤20.00mg/L:±0.30 mg/L >20.00mg/L:±10.0% |
|
response time |
≤ 45s (90% response at 20 ℃) |
|
Salinity compensation error |
±2% |
|
Dissolved oxygen saturation |
scope |
(0.0~600.0)% |
minimum resolution |
0.1% |
|
Electronic unit indication error |
±2.0% |
|
Instrument indication error |
±10.0% |
|
temperature |
scope |
(-10.0~135.0) ℃/(14.0~275.0) °F |
minimum resolution |
0.1 ℃/0.1°F |
|
Electronic unit indication error |
±0.1℃ |
|
Instrument indication error |
±0.3℃(0℃-60℃); ± 1.0 ℃ (other ranges) |
|
power supply |
Rechargeable lithium battery, power adapter (input: AC100~240V, output: DC5V) |
|
Size (mm), Weight (kg) |
90×255×40,0.5 |
|