DZS-708T typeMulti parameter analyzer
● Supports USB flash drive read and write, and can be connected to a scanning gun
Technical parameters:
model |
DZS-708T |
||
Instrument level |
PH/pX: 0.001 level Conductivity: Level 0.5 |
||
mV |
scope |
(-2000.00~2000.00)mV |
|
minimum resolution |
0.01 mV |
||
Electronic unit indication error |
± 0.03% FS or ± 0.1 mV |
||
pH |
scope |
(-2.000~20.000)pH |
|
minimum resolution |
0.001 pH |
||
Electronic unit indication error |
±0.002pH |
||
pX |
scope |
(-2.000~20.000)pX |
|
minimum resolution |
0.001 pX |
||
Electronic unit indication error |
±0.002 pX |
||
ion concentration |
scope |
( 1.00e-9~9.99e+9), Optional units: mol/L, mmol/L, g/L, mg/L, μ g/L, ppm |
|
minimum resolution |
4 significant digits |
||
Electronic unit indication error |
±0.3% |
||
conductivity |
scope |
0.000μS/cm~2000mS/cm |
|
minimum resolution |
0.001μS/cm, Automatically switch according to the range |
||
Electronic unit reference error |
±0.5% FS |
||
resistivity |
scope |
5.00Ω.cm~100.0MΩ.cm |
|
minimum resolution |
0.01 Ω· cm, automatically switches according to the range |
||
Electronic unit reference error |
±0.5% FS |
||
TDS |
scope |
0.000 mg/L~1000g/L |
|
minimum resolution |
0.001mg/L, Automatically switch according to the range |
||
Electronic unit reference error |
±0.5% FS |
||
salinity |
scope |
(0.00~8.00)% |
|
minimum resolution |
0.01% |
||
Electronic unit reference error |
±0.1% |
||
ash content |
Measurement method for ash content of white sugar, Ash of White Suga |
support |
|
Measurement method for ash content of fruit glucose syrup, Ash Content of HFCS |
support |
||
dissolved oxygen |
scope |
Electronic unit: (0.00~99.99) mg/L Supporting range: (0.00~50.00) mg/L |
|
minimum resolution |
0.01 mg/L |
||
Electronic unit indication error |
(0.00~50.00)mg/L,±0.10mg/L (50.0~99.99)mg/L,±0.50mg/L |
||
Instrument indication error |
±0.30mg/L(≤ 20.00mg/L) ±10.0%(> 20.00mg/L) |
||
response time |
≤ 45s (90% response at 20.0 ℃) |
||
Salinity compensation error |
±2% |
||
saturation |
scope |
(0.0~600.0)% |
|
minimum resolution |
0.1% |
||
Electronic unit indication error |
±2.0% |
||
Instrument indication error |
±10.0% |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication error |
±0.1 ℃ |
||
The indication error of the instrument |
±0.3℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
||
power supply |
Power adapter (input: AC100~240V, output: DC24V) |
||
Size (mm), Weight (kg) |
220×195×68,0.95 |
||