DZS-706F typeMulti parameter analyzer
Equipped with a USB interface, it can be connected to a PC through dedicated communication software to achieve data transfer
Technical parameters:
model |
DZS-706F |
|
PH/pX level |
0.01 level |
|
Conductivity level |
Level 1.0 |
|
mV |
scope |
(-2000.0~2000.0)mV |
minimum resolution |
0.1mV |
|
Electronic unit indication value wu difference |
± 0.1% or ± 0.3mV |
|
Electronic unit repeatability |
0.5 mV |
|
Input impedance of electronic unit |
≥1×1012Ω |
|
pH |
scope |
(-2.00~20.00)pH |
minimum resolution |
0.01pH |
|
Electronic unit indication value wu difference |
±0.01pH |
|
Electronic unit repeatability |
0.005pH |
|
Instrument indication Wu difference |
±0.02pH |
|
Instrument repeatability |
0.01pH |
|
pX |
scope |
(-2.00~20.00)pX |
minimum resolution |
0.01pX |
|
Electronic unit indication value wu difference |
±0.01pX |
|
Electronic unit repeatability |
0.005pX |
|
Instrument indication Wu difference |
±0.02pX |
|
Instrument repeatability |
0.01pX |
|
ion concentration |
scope |
(0~19990), optional units mol/L, mmol/L, g/L, mg/L, μ g/L |
minimum resolution |
4 significant digits |
|
Electronic unit indication value wu difference |
±0.5% |
|
conductivity |
scope |
0.000 μS/cm~1000mS/cm |
minimum resolution |
0.001μS/cm, Auto Switch |
|
Electronic unit citation error |
± 1.0%(FS) |
|
Electronic unit repeatability |
0.33%(FS) |
|
Instrument citation error |
±1.50%(FS) |
|
Instrument repeatability |
0.50%(FS) |
|
resistivity |
scope |
5.00Ω·cm~20.00MΩ·cm |
minimum resolution |
0.01 Ω· cm, automatic switching |
|
Electronic unit citation error |
±1.0%(FS) |
|
TDS |
scope |
0.00mg/L~300g/L |
minimum resolution |
0.01mg/L, Auto Switch |
|
Electronic unit citation error |
±1.0%(FS) |
|
salinity |
scope |
(0.00~8.00)% |
minimum resolution |
0.01% |
|
Electronic unit citation error |
±0.2% |
|
The reference of the instrument is poor |
±0.4% |
|
dissolved oxygen |
scope |
(0.00~20.00)mg/L |
minimum resolution |
0.01 mg/L |
|
Electronic unit indication value wu difference |
±0.10mg/L |
|
Zero value wu difference |
≤0.1mg/L |
|
response time |
≤ 45s (90% response at 20.0 ℃) |
|
Instrument indication Wu difference |
±0.30mg/L |
|
saturation |
scope |
(0.0~200.0)% |
minimum resolution |
0.1% |
|
Electronic unit indication value wu difference |
±2.0% |
|
Instrument indication Wu difference |
±10.0% |
|
temperature |
scope |
(-5.0~110.0)℃ |
minimum resolution |
0.1 ℃ |
|
Electronic unit indication value wu difference |
±0.2 ℃ |
|
The difference in the instrument's indication value wu |
±0.4℃(0.0℃-60.0℃) ± 1.0 ℃ (other ranges) |
|
Usage environment |
Environmental temperature: (0-40) ℃ Relative humidity: not exceeding 85% |
|
Size (mm), Weight (kg) |
242 × 195 × 68, approximately 0.9 |
|
power supply |
Power adapter (Input: AC 100-240V Output: DC 9V) |
|