DZS-708L typeMulti parameter analyzer
Main Features
Adopting a 7-inch high-definition color LCD touch screen with clear display
Support both Chinese and English
Temperature units available: ℃ and ° F.
Support functions such as self diagnosis upon startup, automatic shutdown, power-off protection, and factory reset
Support firmware upgrade function, allowing for feature expansion and personalized requirements
Supports IP54 protection level
Divided into basic kit, pH detection kit, ion detection kit, conductivity detection kit, dissolved oxygen detection kit, and multi parameter detection kit
Modular and multi-channel
4 measurement channels
Supports 6 measurement modules: pH measurement module, pX measurement module, EC-T conductivity measurement module (two loop conductivity measurement module), EC-F conductivity measurement module (four loop conductivity measurement module), DO-F dissolved oxygen measurement module (fluorescence method dissolved oxygen measurement module), DO-P dissolved oxygen measurement module (polarographic method dissolved oxygen measurement module)
Free combination, automatic recognition, plug and play
Combined with measurement channels, supports multiple measurement items: pH, ORP, mV, pX, ion concentration, conductivity, resistivity, etc TDS、 Salinity, ash content, dissolved oxygen concentration, dissolved oxygen saturation, temperature
Intelligent operation, automatic recognition, batch detection
Intelligent operating system with functions such as user management method management, method management, sample management, electrode management, data management, GMP management, etc
Support user three-level permission management and password management
Support method management function, built-in 16 methods, support custom measurement methods
Intelligent endpoint discrimination, supporting automatic reading, timed reading, timed interval reading, and manual reading
Support calibration reminder and mandatory calibration function
Support standard solution verification and mandatory verification functions
Support calibration and measurement alarm limit setting
Support connecting automatic samplers to achieve automatic measurement and batch testing of samples
Technical parameters:
model |
DZS-708L typeMulti parameter analyzer |
||
module |
PH measurement module |
||
PH level |
0.001 level |
||
mV |
scope |
(-2000.00~2000.00)mV |
|
minimum resolution |
0.01mV |
||
Electronic unit indication value wu difference |
± 0.03% or ± 0.1mV |
||
pH |
scope |
(-2.000~20.000)pH |
|
minimum resolution |
0.001pH |
||
Electronic unit indication value wu difference |
±0.002pH |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.1 ℃ |
||
The difference in the instrument's indication value wu |
±0.3℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
||
module |
PX measurement module |
||
PH/pX level |
0.001 level |
||
mV |
scope |
(-2000.00~2000.00)mV |
|
minimum resolution |
0.01mV |
||
Electronic unit indication value wu difference |
± 0.03% or ± 0.1mV |
||
pH |
scope |
(-2.000~20.000)pH |
|
minimum resolution |
0.001pH |
||
Electronic unit indication value wu difference |
±0.002pH |
||
pX |
scope |
(-2.000~20.000)pX |
|
minimum resolution |
0.001pX |
||
Electronic unit indication value wu difference |
±0.002pX |
||
ion concentration |
scope |
( 1.000e-9~9.999e+9), Optional units: mol/L, mmol/L, g/L, mg/L, μ g/L, ppm, ppb |
|
minimum resolution |
4 significant digits |
||
Electronic unit indication value wu difference |
±0.3% |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.1 ℃ |
||
The difference in the instrument's indication value wu |
±0.3℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
||
module |
EC-T Measurement Module (Second Ring Conductivity Measurement Module) |
||
Conductivity level |
Level 0.5 |
||
conductivity |
scope |
0.000 μS/cm~3000mS/cm |
|
minimum resolution |
0.001μS/cm, Automatically switch according to the range |
||
Electronic unit citation error |
±0.5% (FS) |
||
Electronic unit repeatability |
0.17%(FS) |
||
Instrument citation error |
±0.80% (FS) |
||
Instrument repeatability |
0.40% (FS) |
||
resistivity |
scope |
5.00Ω.cm~100.0MΩ.cm |
|
minimum resolution |
0.01 Ω· cm, automatically switches according to the range |
||
Electronic unit citation error |
±0.5% (FS) |
||
TDS |
scope |
0.000 mg/L~1000g/L |
|
minimum resolution |
0.001mg/L, Automatically switch according to the range |
||
Electronic unit citation error |
±0.5% (FS) |
||
salinity |
scope |
(0.00~8.00)% |
|
minimum resolution |
0.01% |
||
Electronic unit citation error |
±0.1% |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.1 ℃ |
||
The difference in the instrument's indication value wu |
±0.3℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
||
module |
EC-F Measurement Module (Four Loop Conductivity Measurement Module) |
||
Conductivity level |
Level 1.5 |
||
conductivity |
scope |
50.0 μS/cm~3000mS/cm |
|
minimum resolution |
0.001μS/cm, Automatically switch according to the range |
||
Electronic unit citation error |
±1.5% (FS) |
||
resistivity |
scope |
5.00Ω.cm~20.0kΩ.cm |
|
minimum resolution |
0.01 Ω· cm, automatically switches according to the range |
||
Electronic unit citation error |
±1.5% (FS) |
||
TDS |
scope |
25.0 mg/L~1000g/L |
|
minimum resolution |
0.001mg/L, Automatically switch according to the range |
||
Electronic unit citation error |
±1.5% (FS) |
||
salinity |
scope |
(0.00~8.00)% |
|
minimum resolution |
0.01% |
||
Electronic unit citation error |
±0.2% |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.2 ℃ |
||
The difference in the instrument's indication value wu |
±0.5℃(0.0℃-60.0℃); ± 1.5 ℃ (other ranges) |
||
module |
DO-P measurement module (polarographic dissolved oxygen measurement module) |
||
dissolved oxygen |
scope |
(0.00~99.99)mg/L; |
|
(0.00~50.00) mg/L (supporting measurement range) |
|||
minimum resolution |
0.01mg/L |
||
Electronic unit indication value wu difference |
±0.10mg/L |
||
Instrument repeatability |
0.15mg/L |
||
Zero value wu difference |
≤0.1mg/L |
||
Instrument indication Wu difference |
≤20.00mg/L:±0.30 mg/L; |
||
>20.00mg/L:±10.0% |
|||
response time |
≤ 45s (90% response at 20 ℃) |
||
Salinity compensation wu difference |
±2% |
||
saturation |
scope |
(0.0~600.0)% |
|
minimum resolution |
0.10% |
||
Electronic unit indication value wu difference |
±2.0% |
||
Instrument indication Wu difference |
±10.0% |
||
temperature |
scope |
(-10.0~135.0) ℃/(14.0-275.0)℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.1 ℃ |
||
The difference in the instrument's indication value wu |
±0.3℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
||
module |
DO-F Measurement Module (Fluorescence Dissolved Oxygen Measurement Module) |
||
dissolved oxygen |
scope |
(0.00~20.00)mg/L |
|
minimum resolution |
0.01mg/L |
||
Instrument repeatability |
0.15mg/L |
||
Zero value wu difference |
≤0.1mg/L |
||
Instrument indication Wu difference |
±0.30 mg/L |
||
response time |
≤ 45s (90% response at 20 ℃) |
||
Salinity compensation wu difference |
±2% |
||
saturation |
scope |
(0.0~200.0)% |
|
minimum resolution |
0.10% |
||
Instrument indication Wu difference |
±10.0% |
||
temperature |
scope |
(0.0~50.0) ℃/(32.0~122.0) ℉ |
|
minimum resolution |
0.1 ℃/0.1 ℉ |
||
Electronic unit indication value wu difference |
±0.1 ℃ |
||
Instrument indication Wu difference |
±0.3℃(0℃~50℃) |
||