DZB-712 typePortable multi parameter analyzer
Equipped with a USB interface, it can be connected to a PC through dedicated communication software to achieve data transfer
Technical parameters:
model |
DZB-712 |
|
PH/pX level |
0.01 level |
|
Conductivity level |
Level 1.0 |
|
mV |
scope |
(-2000.0~2000.0)mV |
minimum resolution |
0.1mV |
|
Electronic unit repeatability |
0.5mV |
|
Electronic unit indication value wu difference |
± 0.1% or ± 0.3 mV |
|
pH |
scope |
(-2.00~20.00)pH |
minimum resolution |
0.01pH |
|
Electronic unit indication value wu difference |
±0.01pH |
|
pX |
scope |
(-2.00~20.00)pX |
minimum resolution |
0.01pX |
|
Electronic unit indication value wu difference |
0.01pX |
|
ion concentration |
scope |
(0~19990)Unit: mol/L, mmol/L, g/L, mg/L, μg/L |
minimum resolution |
4 significant digits |
|
Electronic unit indication value wu difference |
±0.5% |
|
conductivity |
scope |
0.000μS/cm~ 500mS/cm |
minimum resolution |
0.001 μ S/cm automatically switches according to the range |
|
Electronic unit reference error |
±1.0%(FS) |
|
resistivity |
scope |
5.00Ω ·cm~20.00MΩ ·cm |
minimum resolution |
0.01 Ω· cm, automatically switches according to the range |
|
Electronic unit reference error |
±1.0% FS |
|
TDS |
scope |
0.00mg/L~300g/L |
minimum resolution |
0.01mg/L automatically switches according to the range |
|
Electronic unit reference error |
±1.0% FS |
|
salinity |
scope |
(0.00~8.00)% |
minimum resolution |
0.01% |
|
Electronic unit reference error |
±0.2% |
|
dissolved oxygen |
scope |
(0.00~50.00)mg/L |
minimum resolution |
0.01 mg/L |
|
Electronic unit indication error |
±0.10mg/L |
|
Instrument indication error |
≤20.00mg/L:±0.30 mg/L >20.00mg/L:±10.0% |
|
response time |
≤ 45s (90% response at 20.0 ℃) |
|
Salinity compensation error |
±2% |
|
saturation |
scope |
(0.0~300.0)% |
minimum resolution |
0.1% |
|
Electronic unit indication error |
±2.0% |
|
Instrument indication error |
±10.0% |
|
temperature |
scope |
(-5.0~110.0) ℃ /(23.0-230.0)℉ |
minimum resolution |
0.1℃/0.1 ℉ |
|
Electronic unit indication error |
±0.2 ℃ |
|
The indication error of the instrument |
±0.4 ℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges) |
|
power supply |
Rechargeable lithium battery, power adapter (input: AC100~240V, Output: DC5V |
|
Size (mm), Weight (kg) |
80×225×35,0.4 |
|