DZB-712 portable multi parameter analyzer detection items: pH/pX value, ion concentration, mV value, conductivity, resistivity TDS、 Salinity, dissolved oxygen, dissolved oxygen saturation, and temperature are displayed clearly on a 3.5-inch high-definition LCD screen.

Product Details

DZB-712 typePortable multi parameter analyzer


【 Main Features 】
Adopting a 3.5-inch high-definition LCD screen, the display is clear
● Temperature units available: ℃ and ° F.
● Support functions such as self diagnosis upon startup, automatic shutdown, power-off protection, and factory reset
● Support firmware upgrade function, allowing for feature expansion and personalized requirements
● Supports IP65 protection level
● Standard configuration includes three composite pH electrodes, composite conductivity electrodes, polarographic dissolved oxygen electrodes, electrode hangers, silicone protective covers, wristbands, portable suitcases, and calibration solutions

multi-purpose machine
● Built in pH/pX, conductivity, and dissolved oxygen measurement units
● Testing items: pH/pX value, ion concentration, mV value, conductivity, resistivity TDS、 Salinity, dissolved oxygen, dissolved oxygen saturation, temperature

Intelligent detection and automatic recognition
Intelligent endpoint discrimination: supports automatic reading, timed reading, timed interval reading, and manual reading
● Support automatic temperature compensation, automatic calibration, and electrode diagnosis

Data management, information traceability
● Support data storage (500 sets each), retrieval, deletion, transmission, and printing
● Compliant with GLP, achieving data traceability
● Supports connecting to standard RS-232 serial port printers to directly print measurement results, with optional printing formats

Equipped with a USB interface, it can be connected to a PC through dedicated communication software to achieve data transfer

Technical parameters:

model

DZB-712

PH/pX level

0.01 level

Conductivity level

Level 1.0

mV

scope

(-2000.0~2000.0)mV

minimum resolution

0.1mV

Electronic unit repeatability

0.5mV

Electronic unit indication value wu difference

± 0.1% or ± 0.3 mV

pH

scope

(-2.00~20.00)pH

minimum resolution

0.01pH

Electronic unit indication value wu difference

±0.01pH

pX

scope

(-2.00~20.00)pX

minimum resolution

0.01pX

Electronic unit indication value wu difference

0.01pX

ion concentration

scope

(0~19990)Unit: mol/L, mmol/L, g/L, mg/L, μg/L

minimum resolution

4 significant digits

Electronic unit indication value wu difference

±0.5%

conductivity

scope

0.000μS/cm~ 500mS/cm

minimum resolution

0.001 μ S/cm automatically switches according to the range

Electronic unit reference error

±1.0%(FS)

resistivity

scope

5.00Ω ·cm~20.00MΩ ·cm

minimum resolution

0.01 Ω· cm, automatically switches according to the range

Electronic unit reference error

±1.0% FS

TDS

scope

0.00mg/L~300g/L

minimum resolution

0.01mg/L automatically switches according to the range

Electronic unit reference error

±1.0% FS

salinity

scope

(0.00~8.00)%

minimum resolution

0.01%

Electronic unit reference error

±0.2%

dissolved oxygen

scope

(0.00~50.00)mg/L

minimum resolution

0.01 mg/L

Electronic unit indication error

±0.10mg/L

Instrument indication error

≤20.00mg/L:±0.30 mg/L

>20.00mg/L:±10.0%

response time

≤ 45s (90% response at 20.0 ℃)

Salinity compensation error

±2%

saturation

scope

(0.0~300.0)%

minimum resolution

0.1%

Electronic unit indication error

±2.0%

Instrument indication error

±10.0%

temperature

scope

(-5.0~110.0) ℃ /(23.0-230.0)℉

minimum resolution

0.1℃/0.1 ℉

Electronic unit indication error

±0.2 ℃

The indication error of the instrument

±0.4 ℃(0.0℃-60.0℃); ± 1.0 ℃ (other ranges)

power supply

Rechargeable lithium battery, power adapter (input:

AC100~240V, Output: DC5V

Size (mm), Weight (kg)

80×225×35,0.4