Brief introduction: pH sensor: Liquid receiving material: Universal type: Ryton body (glass inside) Insertion type: PVDF body (Kynar) Sanitary type: 316 stainless steel liner PVDF body Measurement range: 0-14 pH Temperature range: 0-105 ℃ Pressure range: 0-6.9 bar at 100 ℃ Flow rate range: 0-2m/s, non abrasive fluid accuracy: less than 0.1pHORP sensor: Liquid receiving material: Universal type: Ryton body (glass inside) Insertion type: PVDF body (Kynar) Measurement
Details introduction:
PH sensor:
Liquid receiving material: Universal type: Ryton body (with glass inside)
Insertion type: PVDF body (Kynar)
Sanitary type: 316 stainless steel liner PVDF body
Measurement range: 0-14pH
Temperature range: 0-105 ℃
Pressure range: 0-6.9 bar at 100 ℃
Flow velocity range: 0-2m/s, non abrasive fluid
Accuracy: less than 0.1pH
ORP sensor:
Liquid receiving material: Universal type: Ryton body (with glass inside)
Insertion type: PVDF body (Kynar)
Measurement range: -2000 to+2000mV
Temperature range: 0-105 ℃
Pressure range: 0-6.9 bar at 100 ℃
Flow velocity range: 0-2m/s, non abrasive fluid
Accuracy: ± 20mV, * * compared to standard solution