Welcome Customer !

Membership

Help

Zhuhai Bosen Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Zhuhai Bosen Instrument Co., Ltd

  • E-mail

    441725368@qq.com

  • Phone

    13392981699

  • Address

Contact Now

Digital online ORP detector

NegotiableUpdate on 03/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Brief introduction: The digital oxidation-reduction ORP detector is pre calibrated (no on-site calibration required), plug and play sensor probe electrode protection provides multiple materials, direct data reports, plug and play industrial communication adapter. This ORP sensor can be directly connected to PLC to achieve seamless integration with industrial control systems. Any computer can be used to display data, calibrate and customize measurement systems without the need for intermediate analyzer electronic modules. The sensor probe has been pre calibrated and can replace any other type of sensor without shutting down the system; Save space, time, and cost. Measurement system performance (25 degrees Celsius not affected by cable length)
Product Details
Details introduction:

Digital Datastick oxidation-reduction ORP detector
Work environment:
PEEK or Ryton CPVC
Sensor Probe Sensor Probe
Temperature range: -5 to 95 degrees Celsius -5 to 95 degrees Celsius
*High pressure: 100 psig@95 85 degrees Celsius psig@75 Celsius
*High flow rate: 10 ft/S 10 ft/S

Power requirements (requiring Class II DC power supply):
Voltage range: DC 10-30V
*High power: 200mW
Typical power: 120mW

Structure:
Processing electrode: platinum or gold
Grounding rod: titanium, 316 stainless steel or hash alloy
Sealing ring: Viton (other materials can be used)
Sensor probe material: PEEK, Ryton or CPVC
DataStick material: 316 stainless steel, PEEK, Ryton or CPVC
Weight:
1.2 pounds=0.54kg (PEEK, Ryton or CPVC)
2.6 pounds=1.18kg (316 stainless steel)

Measurement unit:
Measurement unit: mV
Temperature units: Celsius, Fahrenheit

Calibration:
Sample: 1 point
Temperature: 1 and 2 o'clock
ORP and temperature have been pre calibrated before leaving the factory

Temperature compensation options:
Temperature measurement is provided as an independent measurement
Can manually add temperature

Other settings options:
Sensor filter: 0 to 100 seconds
Temperature filter: 0 to 100 seconds

authentication:
**And divergence: CE (EN61326 and EN61326:1998)
Safety: CE (EN 61010-1),UL 508
Dangerous places: UL Class I, Division 2