CMS-6000 modelOn-line Gas ChromatographUsed for monitoring the content of total hydrocarbons, methane, non methane total hydrocarbons, benzene, toluene, ethylbenzene, xylene, trimethylbenzene, styrene, isopropylbenzene, etc. in fixed pollution source exhaust gas. The entire process of sampling gas180 ℃ high temperature noneCold spot heat tracing, quantitative ring quantification, valve injection, chromatographic separation, and dual hydrogen flame ionization detector (dual)FID testing is used to determine the concentrations of total hydrocarbons (THC) and methane (CH4) in the sample gas. The concentration of non methane total hydrocarbons (NMHC) is calculated by subtraction, which is consistent with the national standard (HJ38-2017); Measure the concentration of various benzene derivatives in the sample using post FID.
single unitinstrumentSimultaneously measuring non methane total hydrocarbons and all benzene derivatives, with low monitoring costs.
Dual channel configuration, meeting various national standards/Landmark requirements for analysis cycle.
Stable and secure operation, unmanned operation, and low maintenance costs.
Self protection function: When the gas supply is insufficient, the flame will automatically extinguish and the hydrogen and air flow will be actively shut off.
Automatic restoration of operation: After power on, gas supply restoration, or unexpected power outage restoration, the method of automatic ignition and operation.
Support remote alarm and remote diagnosis functions.
Good repeatability in qualitative and quantitative analysis(<1%), with a low detection limit.
The detection limit of NMHC is as low as 0.01 ppm.
The detection limit of benzene derivatives is as low as0.05 ppm。
High stability temperature control accuracy:0.01 ℃。
High precision electronic pressure control:0.001 psi, Temperature and pressure compensation.
Low maintenance and long service life.
The proportion of imported components is as high as40%.
The software is easy to operate. Modular design, easy to maintain.
Emission Standards for Pollutants in the Rubber Products Industry(GB 27632-2011)
Emission Standards for Pollutants from Petroleum Refining Industry(GB 31570-2015)
Pollutant Emission Standards for Synthetic Resin Industry(GB 31572-2015)
Emission Standards for Air Pollutants in the Printing Industry(DB 31/872-2015)
Emission Standards for Air Pollutants from Industrial Coating Processes(DB 11/1226-2015)
Emission Standards for Air Pollutants from Automotive Manufacturing (Painting) Industry(DB 31/859-2014)
Emission Standards for Pollutants in Biopharmaceutical Industry(DB 33/923-2014)
Emission Standards for Air Pollutants in the Shoe Industry(DB 33/2046-2017)
Suitable for monitoring non methane total hydrocarbons and benzene derivatives in industries such as rubber products, petroleum refining, synthetic resins, printing and coating, automotive manufacturing, and footwear.
|
| project | parameter |
| sex can point mark | detection capability | Total hydrocarbons, methane, non methane total hydrocarbons, benzene, toluene, ethylbenzene, xylene, trimethylbenzene, styrene, isopropylbenzene, etc |
| range | Non methane total hydrocarbons 0.01 ppm~10000 ppm (optional); Benzene derivatives 0.05 ppm~1000 ppm | |
| detection limit | Non methane total hydrocarbons ≤ 0.01 ppm; Benzene derivatives ≤ 0.05 ppm | |
| repetitiveness | < 1% | |
| zero drift | Drift<0.5% F.S. (24h) | |
| range drift | Drift<2.0% F.S. (24h) | |
| Analysis cycle | 2 min~20 min (optional) | |
| be unify ginseng number | Instrument size | 19 inch standard chassis, height 6 U, (430 × 266.7 × 633) mm (W × H × D) |
| Power Specifications | 220 VAC 50 Hz | |
| operating power | 500 W | |
| Input | USB; Relay and 24V power interface; LAN; RS232; VGA | |
| working environment | Temperature: 5 ℃~35 ℃; Humidity 20~90% RH | |
| be unify match place | detector | FID detector |
| Type of carrier gas | High purity nitrogen (≥ 99.999%) | |
| Quantitative method | quantitative loop | |
| Injection method | Valve injection | |
| Sample gas requirements | Environmental temperature~180 ℃; Flow rate not less than 0.5 L/min or pressure not less than 0.1 MPa; No solid particles |