Meizheng Biotechnology Microbial Detection Coliform Group Test Strip LR1302

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Meizheng Biotechnology Microbial Detection Coliform Group Test Strip LR1302 $r $nPremium Series Coliform Group Test Strip Product Introduction $r $nMicroFast The Premium series Coliforms Count (CC) test strip is a pre made culture medium system suitable for the determination of coliforms in various foods. It can also be used for the determination of heat-resistant coliforms in food, with a cultivation temperature of 44.5 ° C for the determination of heat-resistant coliforms; 0.2 C

Product Details

Meizheng Biotechnology Microbial Detection Coliform Group Test Strip LR1302

Meizheng Biotechnology Microbial Detection Coliform Group Test Strip LR1302

Sample processing: Same as GB method Inoculation volume: 1mL/tablet

Cultivation temperature: 36 ± 1 ℃ Cultivation time: 18-24h

Storage conditions: 2-8 ℃, dark and refrigerated

Shelf life: 18 months

Result interpretation: Count the red bacterial colonies that produce gas


Storage of Premium Coliform Group Test Tablets

When unopened, store at a temperature of 2-8 ° C and use up within the shelf life. In environments with high humidity, please restore the test piece to room temperature before opening. After opening, if the test piece is not used up, it needs to be put back into the bag. The aluminum foil bag should be folded twice and sealed with adhesive tape or a sealing clip. It should be stored in the dark (not refrigerated) and used up within one month. When transporting or storing for a short period of time, place the test piece at room temperature.


detection steps

Pre treatment of Premium Series Coliform Test Sample

According to GB4789.3-2016, 25g of solid and semi-solid samples are weighed and placed in a sterile homogenization cup or bag containing 225mL of sterile phosphate buffer solution (or sterile physiological saline). After homogenization, a 1:10 sample homogenate is prepared; Weigh 25mL of liquid sample (or 25g when the result requires coliform bacteria per g of sample) and place it in a sterile homogenization cup or bag containing 225mL of sterile phosphate buffer solution (or sterile physiological saline). After homogenization, prepare a 1:10 sample homogenate.


Take 1mL of 1:10 sample homogenate and inject it into a test tube containing 9mL of diluent. After mixing, it becomes a 1:100 sample homogenate. Repeat this process to prepare a 10 fold series of diluted sample homogenates. For each dilution, use a 1mL sterile pipette or tip.


Select 2-3 suitable dilutions for inoculation testing based on the hygiene condition of the sample (liquid samples can also include stock solutions).