Low frequency dielectric constant dielectric loss tester impedance meter
Low frequency dielectric constant dielectric loss tester impedance meter
Performance characteristics: 4.3-inch TFT LCD display with optional Chinese and English operation interface, 87 high 1MHz test frequency, 10mHz resolution
Balance testing function Transformer parameter testing function 87 High testing speed: 13ms/time Automatic Level Adjustment (ALC) function V, I testing signal level monitoring function Internal built-in DC bias source can be connected to external high current DC bias source 10 point list scanning testing function 30 Ω, 50 Ω, 100 Ω optional internal resistance built-in comparator, 10 level sorting and counting function Internal file storage and external USB file saving Measurement data can be directly saved to USB RS232C, USB, LAN, Handler, GPIB, DCI interfaces
Technical parameter display: 480 × RGB × 272, 4.3-inch TFT LCD display. Test signal frequency: 20Hz-1MHz 87 small resolution: 10mHz, 4-digit frequency Input accuracy: 0.01% AC level Test signal voltage range: 10mV-2Vrms Voltage 87 small resolution: 100 μ V, 3-digit input accuracy ALC ON 10% x set voltage+2mVALC OFF 6% x set voltage+2mV Test signal current range: 100 μ A-20mA Current 87 small resolution: 1 μ A, 3-digit input
Accuracy ALC ON 10% x Set current+20 μ AALC OFF 6% x Set voltage+20 μ ADC bias voltage Source voltage/current range: 0V - ± 5V/0mA - ± 50mA Resolution: 0.5mV/5 μ A Voltage accuracy: 1% x Set voltage+5mVISO ON: Used for inductor and transformer bias testing AC source internal resistance ISO ON: 100 Ω ISO OFF: 30 Ω, 50 Ω, 100 Ω Optional DCR source internal resistance: 30 Ω, 50 Ω, 100 Ω Optional impedance test parameters: | Z |, | Y |, C, L, X, B, R, G, D, Q, θ, DCR, Vdc Idc Test page parameter display: one set Main and auxiliary parameters; 10 point list scanning transformer test parameters: DCR1 (primary, 2 terminals), DCR2 (secondary, 2 terminals), M (mutual inductance), N, 1/N, Phase (phase), Lk (leakage inductance), (primary and secondary capacitance), balance test
Basic measurement accuracy impedance test parameters: 0.05% N: 0.1% Calibration conditions Preheating time: ≥ 30 minutes; Environmental temperature: 23 ± 5oC; Signal voltage: 0.3Vrms-1Vrms; Clear "0": after OPEN and SHORT; Test cable length: 0 m Measurement time (≥ 10 kHz): Fast: 13 ms/time, Medium: 67 ms/time, Slow: 187 ms/time, plus display character refresh time LCR parameter display range | Z |, R, X, DCR: 0.0001 Ω -99.9999 M Ω| Y|,G,B:0.00001μs — 99.9999sC:0.00001pF — 9.99999FL:0.00001μH — 99.9999kHD:0.00001 — 9.99999Q:0.00001 — 99999.9θ(DEG):-179.999o — 179.999oθ(RAD):-3.14159 — 3.14159Δ%:-999.999% — 999.999% Equivalent circuit: series, parallel. Range mode: automatic, hold trigger mode: internal, manual, external. Bus average times: 1-256
Calibration function: open circuit, short circuit full frequency, point frequency calibration, load calibration mathematical operation: direct reading, Δ ABS, Δ% delay time setting: 0-999, 87 small resolution 100us comparator function 10 level sorting, BIN1~BIN9, NG, AUX level counting function
PASS and FAIL front panel LED display
List scanning 10 point list scanning can scan and test frequency, AC voltage/current, internal/external DC bias voltage/current. Each scanning point can be sorted separately. Internal non-volatile memory: 100 sets of LCRZ instrument setting files, 201 test results. External USB memory GIF image LCRZ instrument setting file test data is directly stored in USB memory
Interface I/O interface: Handler, output from the instrument rear panel Serial communication interface: USB, RS232C Parallel communication interface: GPIB interface (optional) Network interface: LAN Memory interface: USB HOST (front panel) Bias current source control interface DCI
The DCI interface can be used to control an external DC bias current source, with a bias current of up to 87 and a maximum of 120A.
Option, DCI and GPIB can only choose one from two. General technical parameters: working temperature and humidity: 0 ℃ -40 ℃, ≤ 90% RH
Power supply voltage: 220V ± 20%, 50Hz ± 2Hz power consumption of 87 large 80VA volume (W × H × D): 280 mm × 88 mm × 370 mm (without sheath), 369 mm × 108 mm × 408 mm (with sheath). Weight: Approximately 5kg
Panel Introduction GDAT-S Front Panel Introduction Trademark and Model: Instrument Trademark and Model [COPY] Key: Image Save Key, saving test result images to USB memory. [MAAS] menu key: Press the [MAAS] key to enter the corresponding test display page for the instrument measurement function. [SETUP] menu key: Press the [SETUP] key to enter the instrument function settings and corresponding test settings page.
[SYSTEM] menu key: Press the [SYSTEM] key to enter the system settings page.
Numerical keys: Numerical keys are used to input data into the instrument. The numerical keys consist of numeric keys [0] to [9], decimal point [.], and [+/-] keys.
[ESC] key: Exit key. [←] key: BackSPACE key. Press this key to delete the number after 87 when entering a numerical value. PASS indicator light: Test judgment qualified LED indicator FAIL indicator light: Test judgment poor LED indicator [RESET] key: Press the [RESET] key to terminate the scan only during automatic transformer scanning, and the instrument will not perform any operations on other pages.
[TRIGGER] key: When the triggering mode of the instrument is set to MAN mode, press this key to manually trigger the instrument. [ENTER] key: The [ENTER] key is used to terminate data input, confirm and save the data displayed on the input line (the line below LCD 87). UNKNOWN: A four terminal test terminal used to connect a four terminal test fixture or test cable for measuring the tested component.
Current excitation voltage sampling (Hpot); Low end voltage sampling (Lpot); Current excitation low-end (Lcur).
Case grounding terminal: This terminal is connected to the instrument case. Can be used to protect or shield grounding connections. CURSOR: The cursor key is used to move the cursor between fields on the LCD display page. When the cursor moves to a certain field, the field appears on the LCD screen
Highlight on the display screen.
Soft keys: Six soft keys can be used to select controls and parameters, with corresponding function definitions on the left side of each soft key. The definition of soft keys varies depending on the displayed page. LOG key: This key automatically records test data and saves system settings in SYSTEM after inserting a USB drive into the MEAS interface.
LCD display screen: 800x480 color TFT LCD display screen, displaying measurement results, measurement conditions, etc. Power switch: Power switch. key: The key is used to allow or disable the output of 0-100mA/10V DC bias power supply. Press the key,
The button will be illuminated, indicating that DC bias output is allowed; Press the key again, and it will turn off,
Indicates the prohibition of DC bias output. In some non test screens where DC BIAS cannot be added, pressing this button will result in no response.
[KEYLOCK] key: Press the [KEYLOCK] key, and it will light up, indicating that the current panel button function is locked; Press the [KEYLOCK] key again, and it will turn off, indicating that the keyboard is unlocked. If the password function is set to "ON", the correct password must be entered when unlocking the keyboard, otherwise the keyboard lock cannot be unlocked. When the instrument is controlled by RS232, the [KEYLOCK] button will be illuminated. Press the [KEYLOCK] key again, and the [KEYLOCK] key will turn off, indicating a return to the local unlock state of the keyboard.
USB HOST interface: used to connect USB flash drive storage for saving and calling files. key: key, this function key is reserved for future expansion use.
GDAT-S Rear Panel Introduction LAN Interface: A network interface that enables control and communication of the network system. USB Device Interface: A USB communication interface that enables online communication with a computer.
RS232C serial interface: a serial communication interface that enables online communication with a computer. Handler interface: HDL interface, which implements the sorting and output of test results.
IEEE-488 interface (optional): GPIB interface for online communication with computers.
Case grounding terminal: This terminal is connected to the instrument case. Can be used to protect or shield grounding connections.
Power socket: used for inputting AC power.
Turn on the power and plug in the three wire power plug. Note that the power supply voltage, frequency, and other conditions should meet the above regulations. The power input phase line L, neutral line N, and ground line E should be the same as the phase and neutral lines on the power plug of this instrument. Turn on the power and press the power switch in the lower left corner of the front panel to turn on the instrument and display the power on screen.
GDAT-S uses a 4.3-inch widescreen TFT display screen with 65k colors to define the display area. The content displayed on the screen is divided into four display areas: the page area indicates the name of the current page. Soft key area: This area is used to display the functional definitions of the soft keys. The definition of soft keys has different functional definitions depending on the position of the cursor in the field.
Measurement result/condition display area: This area displays test result information and current test conditions. Assistant display area: This area is used to display system prompt information.
When pressing the main menu button and selecting the LCR measurement function, it is used to enter the component measurement display page. The main function menu for capacitance, resistance, inductance, and impedance measurement is the start button. The function pages in this section include (use the "soft key" to select the following page functions, the same below):<Measurement Display><File Number Display><File Count Display><List Scan Display>
[SETUP] Function key This key is used to enter the various settings screens for component testing. The functional pages in this section include:<Component Test Settings><User Calibration>Limit Settings>List Settings>
The [SYSTEM] key is used to enter the system settings homepage. The main focus is on the start button of the system settings and file list function menu. The functional pages in this section are: System Settings>Network Settings>Default Settings>System Operations>
After pressing the [SETUP] key, the<Measurement Page>will be displayed. Use the cursor keys ([←] [→] [↑] [↓]) to move the cursor to the desired setting position. For example: "Function: R-X", then press the software build to change "Function: R-X" to "Function: Cp-D".
Press the cursor key [↓] again to bring the cursor to "Frequency: 1.00000KHz". To change the frequency value, press the number key group, select it, and then press the "ENTER" key to complete the test frequency setting, or use the soft key to complete the frequency addition and subtraction setting. The same method can be used to set other parameters. When a numeric key is pressed, the soft key area will display the available unit soft keys. You can press the unit soft key or the [ENTER] key to end data input. When using the [ENTER] key to end data input, the data unit is the default unit for the corresponding field parameter: Hz, V, or A. For example, the default unit for testing frequency is Hz. After setting the value, press the "MEAS" key to enter the measurement display page.
After connecting the testing fixtures related to user calibration operations, the "User Calibration" adjustment should be performed by pressing the menu key [SETUP], pressing the soft key "User Calibration", and entering the<User Calibration>page.