The industrial online ammonia nitrogen automatic monitoring analyzer is a high-precision monitoring equipment independently developed by Shanghai Botuo. It adopts the salicylic acid salt spectrophotometric method and supports automatic switching between 0-10mg/L and 0-50mg/L dual ranges, with measurement accuracy; #177; 5% F.S.。 Equipped with automatic calibration, data storage, and over limit alarm functions, compatible with Modbus RTU communication and 4-20mA output, suitable for scenarios such as surface water, industrial wastewater, municipal sewage, etc., to achieve real-time control of ammonia nitrogen concentration and environmental compliance monitoring.
Industrial online ammonia nitrogen automatic monitoring analyzerIt is a high-precision monitoring equipment independently developed by Shanghai Botuo. It adopts the salicylic acid salt spectrophotometric method and supports automatic switching between 0-10mg/L and 0-50mg/L dual ranges, with a measurement accuracy of ± 5% F.S. Equipped with automatic calibration, data storage, and over limit alarm functions, compatible with Modbus RTU communication and 4-20mA output, suitable for scenarios such as surface water, industrial wastewater, municipal sewage, etc., to achieve real-time control of ammonia nitrogen concentration and environmental compliance monitoring.
Detail Page:
The online automatic monitoring instrument for ammonia nitrogen water quality is a core equipment developed by Shanghai Botuo Instrument for environmental monitoring needs, specifically designed for real-time monitoring of ammonia nitrogen (NH ∝ - N) concentration in water bodies. The device is based onSalicylic acid salt spectrophotometric methodUnder alkaline conditions, precise measurement of ammonia nitrogen concentration in surface water, domestic sewage, and industrial wastewater is achieved through masking agents and color reactions, combined with high-precision photoelectric measurement technology. Its core advantages lie in dual range automatic switching, low reagent consumption, and intelligent operation and maintenance, which can meet the monitoring needs of multiple scenarios such as environmental protection supervision, sewage treatment plant standard discharge, and industrial process optimization. The data efficiency is ≥ 90%, providing reliable data support for water quality safety control.
High precision and high stabilityAdopting imported photoelectric detection modules and automatic temperature compensation technology to eliminate the impact of temperature fluctuations on measurement; The dual range design covers low concentration surface water and high concentration industrial wastewater scenarios, with a measurement repeatability of ≤ 2%, ensuring reliable data.
Intelligent operation and maintenance designSupport automatic calibration (fixed-point/cycle mode), automatic cleaning, and reagent remaining monitoring, with a minimum maintenance cycle of>168 hours (7 days), significantly reducing labor costs; Built in fault self checking function, automatically alarms and records logs in case of extraction abnormalities, heating faults, and other issues.
Flexible data managementMaximum storage capacity of 500000 historical data, supporting curve tracing, USB drive export, and real-time printing; Through the Modbus RTU protocol and integration with the environmental platform, data reporting requirements are met, and the data tagging function distinguishes between normal, maintenance, calibration, and other status data.
Strong environmental adaptabilityThe sampling pipeline is made of corrosion-resistant material (PVC/PPR), which is resistant to acid and alkali corrosion; The digestion chamber adopts a sealed design to avoid contamination caused by reagent volatilization; Suitable for wall mounted or countertop installation, the water collection system supports automatic water level tracking to ensure representative water samples.
Convenience of operation7-inch touch screen with guided menu, supports switching between Chinese/English, simplifies parameter settings and calibration steps; It has functions such as manual measurement, comparison and verification, and can be operated by non professionals after simple training.
Detection PrincipleUnder alkaline conditions, ammonia and ammonium ions in water samples react with salicylates and hypochlorous acid ions in the presence of sodium hydroxide to form colored compounds. By measuring the absorbance at a specific wavelength, the concentration of ammonia nitrogen is calculated according to Lambert Beer's law.
Measurement process:
Water sample collection: The water sample is extracted by an injection pump, and after pre-treatment (sedimentation, filtration), it is sent to the metering unit;
Reagent reaction: Add reagent one (salicylate solution) and reagent two (hypochlorite solution) in sequence, and react at a constant temperature of 50 ℃ in the digestion chamber;
Photoelectric detection: The reaction solution enters the colorimetric cell, measures the absorbance, and converts it into ammonia nitrogen concentration;
Flow path cleaning: After measurement is completed, the pipeline and colorimetric cell are automatically cleaned to avoid cross contamination.
environmental monitoringMonitor the concentration of ammonia nitrogen in natural water bodies such as surface water, lakes, and rivers, grasp the trend of eutrophication in water quality, and provide data support for ecological governance.
sewage treatment plantReal time monitoring of ammonia nitrogen concentration in inflow/outflow to ensure that the discharge indicators comply with the "Pollutant Discharge Standards for Urban Sewage Treatment Plants" (GB18918-2002).
industrial wastewaterMonitoring of wastewater treatment processes in industries such as chemical, printing and dyeing, and food, optimizing denitrification processes, and reducing treatment costs.
municipal water supplyMonitoring of ammonia nitrogen in source water and pipeline water to prevent algae growth and odor issues, ensuring safe drinking water.
routine maintenance:
Check the remaining amount of reagents and the sealing of pipelines every week, and replace the filter element every month;
Perform user calibration every 3 months and verify measurement accuracy using standard solutions;
Regularly clean the measuring tube and colorimetric cell to avoid contamination from affecting the detection.
troubleshootingCommon faults such as "abnormal liquid extraction" can be checked for reagent level and pipeline blockage; Abnormal heating "requires investigation of the connection between the heating wire and fan. For complex issues, please contact after-sales remote diagnosis.
Service GuaranteeCore components come with a one-year warranty and lifetime technical support; National service network coverage, engineers come to repair within 48 hours, and provide free operation training and reagent preparation guidance.