Features:
Lung protection: Remote solvent not inhaled
Eye protection: UV light does not enter the eyes when projected onto the screen
Record: Real time transmission of electronic records
Security: Wireless design, intelligent and lightweight
Portable: lightweight, agile, highly integrated
accessories:
Charger, can be paired with plastic holder and baffle
Specifications:
Operation Manual:
1. The power switch is located on the left side of the handle. To turn on the board viewer, simply move the switch downwards.
2. The light source switch is located on the front of the handle, with three levels of control: "365 nm" and "neutral" “254 nm”; Pull the switch up (down), the 365nm (254nm) light will turn on, and at the same time, the up (down) indicator light will turn on. Turn the switch back to the middle position, and the light will turn off.
3. Lightly press the photo button to take a picture, and the image will be saved for easy viewing. Tap again to reactivate the camera function.
After use, turn the power switch upwards and turn off the UV light.
Precautions:
1. Suggested working environment temperature range: -20~40 ° C;
2. This device should be placed in a cool, ventilated, and dry place; Stay away from flammable and explosive materials, corrosive materials, dust, etc. It is strictly prohibited to use and store in unprotected acidic or alkaline environments;
If the device is not used for a long time, it should be turned on regularly to check its working condition to avoid circuit damage, usually once a week;
4. If the equipment body should be kept clean, it is strictly prohibited to let water or other foreign objects enter the equipment. Once the above problems occur, immediately shut down and report for repair. After confirming that all hidden dangers inside the instrument have been eliminated, it can be reused;
5. If any abnormalities such as short circuit or smoking are found, immediately shut down and report for repair. It is strictly prohibited to turn on the device during the waiting period; 6. Non professionals are prohibited from disassembling and assembling to avoid damaging the circuit.
7. Avoid contact with organic solvents.
Product operation: