productFeatures:
Product Innovation:Multiple light sources are designed on the lamp board to evenly cover the orifice plate with light, and the liquid required for the experiment is directly irradiated vertically from top to bottom;
The optional wavelength range of the light source is 365~980 nm. The lamp cover is designed with modularity, magnetic adsorption, and can be efficiently replaced;
Equipped with three layers of slots, the position of the orifice plate can be freely changed, and the distance between it and the light source can be adjusted;
Involving initial screening of chemical reactions, both homogeneous and heterogeneous reactions can be effectively illuminated, and can also be used for photocatalytic enzyme catalysis and light breeding in the field of biology.

Accessories
Replacement LED light cover, compatible with power supply unit



Operation Instructions:
Connect the power supply, turn on the power switch, turn on the fan, and adjust the set speed;
Push the prepared 96 hole plate into the slot of the hollow tray, select the desired gear for the experimental environment, and further push the entire box into contact with the tray and the inner wall of the box;
The screen light indicates that the reactor is in working condition;
Set the required light source intensity and wattage for the reaction;
The light is on and the fan is running. The reaction system begins to react; After use, turn off the light source, set the knob to zero, remove the 96 hole plate, pack it up and put it back in place;
Replace LED light sources with different wavelengths, select the required light source for the experiment, and use a screwdriver to disassemble and replace them.

Suggested working environment temperature range: -20~40 ℃;
This device should be placed in a cool, ventilated, and dry place; Stay away from flammable and explosive materials, corrosive materials, dust, etc. It is strictly prohibited to use and store in unprotected acidic or alkaline environments;
If the device is not used for a long time, it should be turned on regularly to check its working condition to avoid circuit damage, usually once a week;
The equipment body should be kept clean, and water or other foreign objects are strictly prohibited inside the equipment. Once the above problems occur, immediately shut down and report for repair. After confirming that all hidden dangers inside the instrument have been eliminated, it can be reused;
If any abnormalities such as short circuit, tripping, or smoking are found, immediately shut down and report for repair. It is strictly prohibited to turn on the machine during the waiting period;
Non professionals are prohibited from disassembling and assembling to avoid damaging the circuit.