Welcome Customer !

Membership

Help

Yunpu Instrument (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Yunpu Instrument (Shanghai) Co., Ltd

  • E-mail

    info@wintoptest.com

  • Phone

    13764481606

  • Address

    Room 2050, Pudong Zhangjiang Chuangzhi Liangcang, No. 298 Kangqiao East Road, Pudong New Area, Shanghai

Contact Now

Huashi Green Instrument: Full temperature range photoreactor

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Applications: drug synthesis, drug screening, material modification, biological modification

Product Details

华师绿仪:全温程光反应仪Product Features

Parallel eight digit intelligent beauty

Built in light source, portable operation

Save space and facilitate storage

room temperature low temperature Can be applied

Module Design Light source replaceable

华师绿仪:全温程光反应仪Featured features:

1. Band range 365~980 nm, Different wavelength light sources can be selected;

2. Parallel 8 workstations, each independent, with independently adjustable wattage;

3. Specially designed light guideMaterial, uniform irradiation;

4. Extend and retract the power cord to save space and facilitate storage;

5. Temperature range -80~80 ℃, precise temperature control photoresponse module;

6. Adaptation standards 19 # Schlenk reaction tube, no customization required, easy to use.

华师绿仪:全温程光反应仪Accessories

8 fiber optic light sources, power cords

华师绿仪:全温程光反应仪Specifications:

华师绿仪:全温程光反应仪

华师绿仪:全温程光反应仪Operation Instructions:

1. Connect the power and turn on the switch: The power switch is located at the bottom back of the instrument, with "one" indicating on and "O" indicating off. The startup screen lights up.

2. Each fiber optic tube has a Type-C interface, and the display screen position corresponds one-to-one with the position of the data cable below. Pull out the data cable and connect it to the Type-C interface of the corresponding fiber optic tube, and the "lightning" symbol will be displayed at the corresponding position on the screen.

3. Start the experiment: After adding the reaction solution to the reaction tube, insert the fiber optic tube into the reaction tube and place it in a low-temperature bath or oil bath.

4. Set power: The display screen position corresponds one-to-one with the data cable below. Touch the corresponding position on the display screen and turn the knob to adjust the wattage. Rotate the knob counterclockwise (clockwise) to control the corresponding hole position power to decrease (increase).

5. Turn off the instrument: Turn off the power switch, cut off the power, unplug the data cable, retract it, and place the fiber optic tube back into the corresponding hole.

华师绿仪:全温程光反应仪Notes:

1. Suggested working environment temperature range: -80~80 ℃;

2. This device should be placed in a cool, ventilated, and dry place; Stay away from flammable and explosive materials, corrosive materials, dust, etc. It is strictly prohibited to use and store in unprotected acidic or alkaline environments;

If the device is not used for a long time, it should be turned on regularly to check its working condition to avoid circuit damage, usually once a week;

4. The equipment body should be kept clean, and water or other foreign objects are strictly prohibited inside the equipment. Once the above problems occur, immediately shut down and report for repair. After confirming that all hidden dangers inside the instrument have been eliminated, it can be reused;

5. If any abnormalities such as short circuit or smoking are found, immediately shut down and report for repair. It is strictly prohibited to turn on the device during the waiting period;

6. Non professionals are prohibited from disassembling and assembling to avoid damaging the circuit;

7. The Type-C connection port of the fiber optic tube in this device cannot be connected to a mobile phone charger without authorization to avoid damage caused by excessive power.

华师绿仪:全温程光反应仪Product operation:

华师绿仪:全温程光反应仪 华师绿仪:全温程光反应仪