Honeywell AWM700 series amplified gas mass flow sensor, compensating type. 200 SLPM, ± 300 SLPM. Analog output
Honeywell Sensor AWM700 SeriesProduct Introduction: The AWM700 series micro bridge gas mass flow sensor, with its specially designed bypass flow housing, can achieve coaxial flow measurement. The sensor can measure a flow rate of up to 200 standard liters per minute (SLPM), while typically producing a pressure drop of 1 in H2O. The AWM700 has a large measurement range and small size.
The response time of the sensor is 6 milliseconds and requires a 10 Vdc power supply, but only consumes 60 mW of power. The compact plastic packaging can withstand a pressure of 25 psi without compromising performance. Plug in APP compatible connector for reliable connection.
Sensors are also highly suitable for use in portable devices and battery powered applications. The AWM700 series sensors have mature reliability, high accuracy, and precision operating characteristics in the health ventilation market and health analysis instrument applications.
It has high accuracy throughout its entire lifecycle and does not require recalibration. The AWM700 sensor circuit can perform amplification and temperature compensation functions.
Attention: Product damage
The AWM series micro bridge gas mass flow sensor is not suitable for measuring liquid flow, as liquid passing through the sensor can damage the sensor.
Honeywell Sensor AWM700 SeriesBasic parameters:
Port type: 22 mm, conical.
Storage temperature: -40 ° C to 90 ° C [-40 ° F to 194 ° F].
Flow/pressure range:+200 SLPM
Power consumption: maximum value of 60 mW.
Compensation temperature range: 10 ° C to 40 ° C [50 ° F to 104 ° F]
Signal conditioning: magnify
Media compatibility: only for dry gases.
Zero position throughout the entire temperature range: typical value ± 0.025 Vdc.
Power supply voltage: minimum 8.0 Vdc, typical value 10.0 Vdc, maximum 15.0 Vdc.
Working temperature: -25 ° C to 85 ° C [-13 ° F to 185 ° F]
Response time: typical value of 6ms
The regular models include: AWM720P1
AWM5103 ,AWM5104,AWM5102 ,AWM5101,
Connector ordering guide
Note: Within the given flow range of the calibration gas, all models can achieve linear output of 1-5 VDC through 10 VDC power supply.
1. Nitrogen calibration is the same as oxygen and atmospheric calibration.
2. Carbon dioxide calibration is the same as N2O calibration.
Honeywell Sensor AWM700 SeriessupplyFor more product details, please call our company.