Themys HPHigh pressure comprehensive thermal analysis platform

Themys HPUsed for measuring high pressure temperature and mass changes.
THEMYS HPCan be applied to high-temperature decomposition, combustion, or gasification research, simulating the reaction conditions during the conversion of coal, biomass, or waste into energy, specifically designed for high-temperature and high-pressure oxidation research of metal alloys.
THEMYS HPIt is a controllable high voltageTGA.
THEMYS HPEquipped with a high-temperature furnace body and a suspended balance to achieve the best quality change measurement accuracy, the dual back pressure regulating device can achieve precise pressure control.
Why are we different from others?
High temperature and high pressure performance
Single furnace can achieve high temperature1200℃ and high pressure150 barSimulate real reaction conditions
High precision and versatility
High performance suspension symmetrical balance specially designed forTGADesigned for application
•Continuous measurement of sample quality changes
•significant reductionTGASignal background noise, reducing drift
•Optimize the interaction between gas and sample
safety
Compliant with European pressure equipment standards2014/68/EU -第2Group gas(Non explosive, non flammable, non-toxic)
Basic Parameters | ||
temperature range(℃) |
room temperature~ 1200 |
|
Programmable temperature scanning rate(℃/min) |
0.01 ~ 100a |
|
Crucible volume and maximum sample size(Ml) |
1300 |
|
air circuit |
Single airflow option |
3Road carrier gas, optional among them1Road intake, 1MFC |
Advanced Gas Panel Options |
3Road carrier gas, optional among them1Road intake+ 1Road auxiliary gas, 2 MFC |
|
vacuum |
First level vacuum(< 1 mbar)Forced vacuum(< 5*10-2mbar) |
|
balance | ||
range(mg) |
small |
±200 |
big |
±2000 |
|
Maximum sample size(g) |
35 |
|
Thermogravimetric baseline drift(Temperature scanningC |
±200ug |
|
Balance resolution(Mg) |
0.0023 |
|
a. PatmThe value may vary due to pressure;c.typical data | ||
High pressure comprehensive thermal analysis platformThemys HP's balance is a specially designed high-pressure version. The balance based on the suspended symmetrical principle has the best quality data accuracy and stability.
The sample temperature is controlled by a platinum based heating element protected by an alumina tube.
The temperature and pressure range of a single furnace body and balance can reach 1200 ℃ and 150 bar.
It avoids the tedious operation of changing the furnace body multiple times due to changing different samples or testing conditions.
The high-sensitivity temperature control thermocouple is placed under the sample crucible.
THEMYS HP has built-in user safety and instrument safety systems. include:
·Safety system to avoid excessive pressure difference inside and outside the furnace;
·Four safety valves arranged at different positions in the air circuit of the whole machine;
·Do not open the furnace when the pressure is above 1.2 bar;
The system is equipped with a dual back pressure regulating device for precise control of test pressure during low-pressure (1-6 bar) and high-pressure (6-150 bar) operations