Themys LVComprehensive Thermal Analysis Platform for Large Sample Quantity

Comprehensive Thermal Analysis Platform for Large Sample QuantityThemys LVUsed for measuring temperature, mass changes, heat and heat flux, size changes, and gas emissions of large samples.
THEMYS LVThe comprehensive thermal analyzer is equipped with a large load balance and a high-temperature furnace body, making it a large volume high-temperature comprehensive thermal analysis platform (maximum sample size)18mLThe highest temperature2000℃)。
THEMYS LVThe comprehensive thermal analyzer is also suitable forTHEMYSOnce encountering large sample sizes in the application of product lines,THEMYS LVIt can play an important role, including raw material testing, oxidation and corrosion of metal parts, and high-temperature decomposition of waste materials.
Why are we different from others?
Ultra high temperature performance
The highest single furnace can reach2000℃
bulk volume
Used for testing larger samples
High precision, high flexibility
Hanging symmetrical upper balance, specially designed forTGAdesign
Modular design, adaptable to various needs
Highest to2000℃:TGA, DTA, TG-DTA, TMA
Highest to1600℃:TG-DSC,DSC
TMAmodule
Low load applications can better reflect the properties of the sample itself
External integration capability
Can be used in conjunction with various instruments, such asFTIR, MS, GCMS, MSFTIR,orFTIR-GCMS
Basic Parameters |
TGA |
STA |
TMA |
||
DTA, TG-DTA |
DSC, TG-DSC |
||||
temperature range(℃) |
room temperature~ 2000 |
room temperature~ 2000 |
room temperature~ 1600 |
room temperature~ 2000 |
|
Programmable temperature scanning rate(℃/min) |
|||||
Crucible volume and maximum sample size |
4.5 ~ 18.1 mlor |
220 ~ 500Ml |
360 ~ 420Ml |
Height:50 |
|
air circuit |
Mixed gas options |
3Road carrier gas, optional among them1Road intake+1Road auxiliary gas,2MFC |
|||
Corrosive gas options |
3Road carrier gas, optional among them1Road intake, 1MFC + |
||||
vacuum |
Primary vacuum(< 5*10-2 mbar),Secondary vacuum optional |
||||
balance | |||||
range(mg) |
small |
±200 |
|||
big |
±2000 |
||||
Maximum sample size(g) |
100 |
||||
Balance resolution(ug) |
0.02 |
||||
DTA/DSC |
DTA, TG-DTA |
DSC, TG-DSC |
|||
Calorimetry accuracy(%)c,e |
±2 |
||||
temperature accuracyc, e |
±1 |
||||
TMA | |||||
Resolution(nm) |
1.6 |
||||
Measurement range(mm) |
±6 |
||||
b.Under helium atmosphere;c.typical datae.Based on the melting of metal standard samples;Parameters may change | |||||
andTHEMYSSimilarly,THEMYS LVThe balance module can be connected vertically to a device used for measuring thermal expansionTMAmoduleSwitching between each other.
Through careful design,THEMYS LVofHanging scales are extremely reliable and can adapt to significant changes in the mass of heavier samples.
The suspension principle of the systemOptimized the interaction between gas and sampleMake the sampleMaximize exposure to environmental atmosphere.
various, multiple, diverse, a variety ofGas controloption:
·Equipped with intelligent softwarePneumatic control systemDuring the sample pretreatment or testing process, the gas type can be switched, the flow rate can be controlled, and the gas mixing ratio can be changed according to the program;
·Vacuum operationAnd pre-processing options;
·Corrosive atmosphereThe testing kit can protect the instrument while testing the reactivity of the sample.
THEMYS LVThe furnace body isThe largest thermal analyzer in the market.
THEMYS LVHaving a large uniform temperature range, it can handle diameters of20mmHeight80mmConduct high-precision testing on the samples.
Combining multiple configurationsSingle graphite furnaceCan adapt to various testing conditions and provide multiple thermal analysis data.
TGA, DTA, DSCaccessories:
·from220Mlto18.1mlCeramic or metal crucible
·TGHanging wire or sensor
·DTAandDSCThe temperature for sensor testing has reached1750℃ and1600℃
Equipped with high-sensitivity thermocouplesTemperature control systemTo optimize the precise temperature control requirements for all temperature zones.