Welcome Customer !

Membership

Help

Kaipu Technology (Shanghai) Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Comprehensive Thermal Analysis Platform for Large Sample Quantity

NegotiableUpdate on 12/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Themys LV, a comprehensive thermal analysis platform for large sample quantities, is used to measure temperature, mass changes, heat and heat flux, size changes, and gas emissions of large samples. The large load balance and high-temperature furnace body equipped on the nTHEMYS LV comprehensive thermal analyzer make it a large volume high-temperature comprehensive thermal analysis platform (with a maximum sample volume of 18mL and a maximum temperature of 2000 ℃). Once encountering large sample sizes, THEMYS LV can play an important role, including raw material testing, oxidation and corrosion of metal parts, and high-temperature decomposition of waste materials.
Product Details


Themys LVComprehensive Thermal Analysis Platform for Large Sample Quantity

大样品量综合热分析平台


Comprehensive Thermal Analysis Platform for Large Sample QuantityThemys LVUsed for measuring temperature, mass changes, heat and heat flux, size changes, and gas emissions of large samples.

THEMYS LVThe comprehensive thermal analyzer is equipped with a large load balance and a high-temperature furnace body, making it a large volume high-temperature comprehensive thermal analysis platform (maximum sample size)18mLThe highest temperature2000℃)。

THEMYS LVThe comprehensive thermal analyzer is also suitable forTHEMYSOnce encountering large sample sizes in the application of product lines,THEMYS LVIt can play an important role, including raw material testing, oxidation and corrosion of metal parts, and high-temperature decomposition of waste materials.

Why are we different from others?

Ultra high temperature performance

The highest single furnace can reach2000

bulk volume

Used for testing larger samples

High precision, high flexibility

Hanging symmetrical upper balance, specially designed forTGAdesign

Modular design, adaptable to various needs

Highest to2000℃:TGA, DTA, TG-DTA, TMA

Highest to1600℃:TG-DSC,DSC

TMAmodule

Low load applications can better reflect the properties of the sample itself

External integration capability

Can be used in conjunction with various instruments, such asFTIR, MS, GCMS, MSFTIR,orFTIR-GCMS

Basic Parameters

TGA

STA

TMA

DTA, TG-DTA

DSC, TG-DSC

temperature range()

room temperature~ 2000

room temperature~ 2000

room temperature~ 1600

room temperature~ 2000

Programmable temperature scanning rate(/min)

0.01~20

Crucible volume and maximum sample size

4.5 ~ 18.1 mlor
height: 80diameter: 20 mm
Excluding crucible

220 ~ 500Ml

360 ~ 420Ml

Height:50
Diameter:15mm

air circuit

Mixed gas options

3Road carrier gas, optional among them1Road intake+1Road auxiliary gas,2MFC

Corrosive gas options

3Road carrier gas, optional among them1Road intake, 1MFC +
1
Corrosive gas pipelines without mass flow control

vacuum

Primary vacuum(< 5*10-2 mbar),Secondary vacuum optional

balance

range(mg)

small

±200



big

±2000

Maximum sample size(g)

100

Balance resolution(ug)

0.02

DTA/DSC


DTA, TG-DTA

DSC, TG-DSC


Calorimetry accuracy(%)c,e


±2


temperature accuracyc, e


±1


TMA

Resolution(nm)




1.6

Measurement range(mm




±6

b.Under helium atmosphere;c.typical datae.Based on the melting of metal standard samples;Parameters may change


andTHEMYSSimilarly,THEMYS LVThe balance module can be connected vertically to a device used for measuring thermal expansionTMAmoduleSwitching between each other.

Through careful design,THEMYS LVofHanging scales are extremely reliable and can adapt to significant changes in the mass of heavier samples.

The suspension principle of the systemOptimized the interaction between gas and sampleMake the sampleMaximize exposure to environmental atmosphere.

various, multiple, diverse, a variety ofGas controloption:

·Equipped with intelligent softwarePneumatic control systemDuring the sample pretreatment or testing process, the gas type can be switched, the flow rate can be controlled, and the gas mixing ratio can be changed according to the program;

·Vacuum operationAnd pre-processing options;

·Corrosive atmosphereThe testing kit can protect the instrument while testing the reactivity of the sample.

THEMYS LVThe furnace body isThe largest thermal analyzer in the market.

THEMYS LVHaving a large uniform temperature range, it can handle diameters of20mmHeight80mmConduct high-precision testing on the samples.

Combining multiple configurationsSingle graphite furnaceCan adapt to various testing conditions and provide multiple thermal analysis data.

TGA, DTA, DSCaccessories:

·from220Mlto18.1mlCeramic or metal crucible

·TGHanging wire or sensor

·DTAandDSCThe temperature for sensor testing has reached1750℃ and1600

Equipped with high-sensitivity thermocouplesTemperature control systemTo optimize the precise temperature control requirements for all temperature zones.