The fully automatic dielectric loss dielectric constant tester consists of a high-frequency impedance analyzer, testing device, and standard dielectric samples. It can test the high and low frequency dielectric constant (ε) and dielectric loss angle (D or tan δ) of insulation materials. It complies with the requirements of national standard GB/T 1409-2006, American standard ASTM D150, and IEC60250 specifications.
Fully automatic dielectric loss dielectric constanttester
Product Usage Product Usage
Fully automatic dielectric loss dielectric constant testerComposed of a high-frequency impedance analyzer, testing device, and standard dielectric samples, it is capable of analyzing insulation materials High and low frequency dielectric constants(ε) Testing of dielectric loss angle (D or tan δ). It complies with the requirements of national standard GB/T 1409-2006, American standard ASTM D150, and IEC60250 specifications.
Fully automatic dielectric loss dielectric constant testerThe working frequency range is20Hz~1Mhz 2Mhz 5Mhz, Three optionsIt can achieve the relative dielectric constant of insulating materials within the working frequency(ε) Testing of changes in dielectric loss angle (D or tan δ).
Fully automatic dielectric loss dielectric constant testerThe testing device is composed of flat capacitors, which are generally used to clamp the tested sample and equipped with a high-frequency impedance analyzer as an indicator instrument. The dielectric constant and loss value of insulating materials are determined by placing the tested sample into a flat capacitor and an unshielded sampleD value (loss value) variation and Cp (capacitance value) readingYou can directly calculate without manual laborGot it.
Overview
HJS-S is a new type of impedance analyzer with multiple functions and higher testing frequency. It is small in size, compact and portable, and easy to use on shelves. The basic accuracy of this series of instruments is 0.05%, and the testing frequency is the highest2MHz and 10mHz resolution, 4.3-inch LCD screen with Chinese and English operation interface, easy and simple operation. Integrated transformer testing function and balance testing function, improving testing efficiency. The instrument provides rich interfaces that can meet various requirements for automatic sorting testing, data transmission, and storage.
Solid execution standard GB/T 1409-2006(Measurement of electrical insulation materials at power frequency, audio frequency, and high frequencyRecommended methods for capacitance and dielectric loss factor (including meter wave wavelength)) ) liquid
advantagefeatureAdvantages and Characteristics
1. The dielectric constant and dielectric loss can be directly obtained without manual calculation
2Testeable resistance
3 4.3-inch TFT LCD display
4 Chinese and English optional operation interface
5 highest5Test frequency in MHz
6Balance testing function
7 Transformer parameter testing function
8 Maximum testing speed: 13ms/time
9 Automatic level adjustment of voltage or current(ALC function
10 V. I test signal level monitoring function
11 Internally equipped with DC bias source
12 Can be connected to an external high current DC bias source
13 10 point list scanning test function
14 30 Ω, 50 Ω, 100 Ω optional internal resistance
15 Built in comparator,10 levels of sorting and counting function
16 Internal file storage and externalSave USB files
17 Measurement data can be directly saved toUSB drive
18 RS232C, USB, LAN, Handler, GPIB, DCI interfaces
19 High frequency impedance analyzer capacitance valueCp resolution of 0.00001pF and 6-digit D value display ensure the accuracy and repeatability of ε and D values.
20 The measurement range of dielectric constant can reach1~105
ε and DPerformance: |
Solid insulation material testing frequencyTesting of ε and D variations between 20Hz and 2MHz. |
Measurement range of ε and D |
ε:1~105,D:0.1~0.00005, |
Measurement accuracy of ε and D (10kHz) |
ε:±2% , D:±5%±0.0001 |
test parameters |
C, L, R,Z,Y,X,B, G, D, Q, θ,DCR |
test frequency |
20 Hz~2MHz, 10mHz step |
Test signal electricity |
f≤1MHz 10mV~5V,±(10%+10mV) 平:f>1MHz 10mV~1V,±(20%+10mV) |
Output impedance |
10Ω, 30Ω, 50Ω, 100Ω |
Basic accuracy |
0.1% |
display range |
L 0.0001 uH ~ 9.9999kH
C:0.0001 pF ~ 9.9999F
R,X,Z,DCR:0.0001 Ω ~ 99.999 MΩ
|
display range |
Y, B, G 0.0001 nS ~ 99.999 S
D:0.0001 ~ 9.9999
Q:0.0001 ~ 99999
θ:-179.99°~ 179.99°
|
measure speed |
fast: 200次/s(f﹥30 kHz) ,100 次/s(f﹥1 kHz) |
medium speed |
25 times/s, slow speed: 5 times/s |
Calibration function |
open circuit /Short circuit point frequency, sweep frequency reset, load calibration |
Equivalent method |
series connectionParallel connection method |
Range method |
automaticMaintain it |
display mode |
direct reading, Δ, Δ% |
Trigger method |
internalManual, External, Bus |
Internal DC bias |
Voltage mode-5V~+5V, ± (10%+10mV), 1mV step |
Source setting |
Current mode (internal resistance is)50 Ω) -100mA~+100mA, ± (10%+0.2mA), 20uA step |
Comparator function |
10 levels of sorting and counting function |
monitor |
320 × 240 dot matrix graphic LCD display |
存储器 |
Can be saved20 sets of instrument settings |
USB DEVICE( USBTMC and USBCDC support) USB HOST(FAT16 and FAT32 support) |
interface |
LAN(LXI class C support) RS232C HANDLERGPIB(选件) |
Working frequency range |
20Hz~2MHz digital synthesis, |
precision |
±0.02% |
Capacitance measurement range |
0.00001pF to 9.99999F six digit digital display |
Basic error in capacitance measurement |
±0.05% |
Loss factorD value range |
0.00001 to 9.99999 six digit digital display |
Dielectric constant testing device (including protective electrode) |
The precision dielectric constant testing device provides testing electrodes that can measure the diameterφ10~56mm, thickness<10mmAccurate measurement of the sample. |
It can be set up as three methods for different samples: contact electrode method, thin film electrode method, and non-contact method, to adapt to testing soft materials, uneven surfaces, and thin film samples. |
Differential head resolution |
10μm |
Maximum withstand voltage |
±42Vp(AC+DC) |
Cable length setting |
1m |
Maximum usage frequency |
5MHz |
Electrode schematic diagram(Electrode schematic diagram)
Equipment labelQuasi configurationEquipment standard configuration
experimenthost a
Experimental electricityextreme oneset
data cable a strip
power cord a strip
Instruction Manual a copy
Certificate of Conformity a copy
Warranty Card a copy