Product Features:
At the bottomStable and secure operation, achieving unmanned operation and low maintenance costs:
uSelf protection function, when the gas supply is insufficient, the flame will automatically extinguish and the hydrogen and air flow will be turned off to prevent leakage.
uAutomatic ignition, automatically ignites and runs after startup, restoration of gas supply, or unexpected power outage.
uSupport remote alarm and remote diagnostic functions.
At the bottominstrumentGood repeatability in qualitative and quantitative analysis(≤1%)Low detection limit:
The detection limit of FID is as low as 1.8 × 10-12 g/s.
uHigh stability temperature control system:0.01 ℃。
uHigh precision electronic pressure control unitEPC(0.001psi)Realize temperature and pressure compensation.
At the bottomLow maintenance and long service life: the proportion of imported parts is as high as40%.
At the bottomThe software is easy to operate and maintain,SINZEN supports customized services.
Typical spectrogram:


Technical Specifications:
| be unify ginseng number | instrumentsize | 19 inch standard chassis, height 6 U, 633 mm x 430 mm x 266.7 mm (L * W * H) |
| Power Specifications | 220 VAC 50 Hz | |
| operating power | 500W | |
| Analog input/output | USB; Relay and 24V power interface; LAN; RS232; VGA | |
| working environment | Temperature:5~35 ℃Humidity 20~90% RH | |
| sex can point mark | detection capability | Methane, total hydrocarbons, non methane total hydrocarbons, benzene, toluene, ethylbenzene, xylene, trimethylbenzene, styrene, isopropylbenzene |
| range | Methane, total hydrocarbons, non methane total hydrocarbons0.01~10000 ppm(Optional); Benzene derivatives 0.05~1000 ppm (optional) | |
| detection limit | methane10 ppb | |
| Total hydrocarbons10 ppb | ||
| Non-Methane Total Hydrocarbons (NMTHC)10 ppb | ||
| BTEX (Benzene, Toluene, Ethylbenzene, Xylenes)50 ppb | ||
| repetitiveness | <1% | |
| zero drift | drift<0.5%F.S.(24h) | |
| range drift | drift<2.0%F.S.(24h) | |
| Analysis cycle | 2 min~20 min (optional) |
| be unify match place | detector | FID detector |
| Type of carrier gas | High purity nitrogen or zero order air(≥99.999%) | |
| Quantitative method | quantitative loop | |
| Injection method | Valve injection | |
| Sample gas requirements | Sample gas temperature: ambient temperature~180 ℃The flow rate shall not be less than 0.5 L/min or the pressure shall not be less than 0.1 MPa; No solid particles |
applicationscope: