Welcome Customer !

Membership

Help

Shanghai Shenhong Valve Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products
Product Categories

Shanghai Shenhong Valve Co., Ltd

  • E-mail

  • Phone

  • Address

    Jinze Industrial Park, Qingpu District, Shanghai

Contact Now

Electric shut-off valve with heat dissipation

NegotiableUpdate on 05/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

J941H electric shut-off valve with heat dissipation is commonly used in situations where frequent opening and closing are required to achieve large-scale centralized control. When working, the operation can be controlled by connecting to a 220VAC or 380V power supply. A control module can also be added to input control signals (4-20mADC or 1-5VDC) for adjustment and control. A handwheel can also be installed for manual control when necessary.

Product Details

J941HElectric shut-off valve with heat dissipationProduct Description

Suitable for use as an opening and closing mechanism in high-pressure and high-temperature pipelines such as primary and secondary steam valves in thermal power plants, as well as in high-temperature chemical pipelines. The valve body material is forged from carbon steel stainless steel (1Cr18Ni9Ti) or heat-resistant alloy steel, and the sealing surface is welded with hard alloy It is an opening and closing device with a heat dissipation device, welded to the pipeline by butt welding, suitable for high temperature and high pressure applications. Main technical parameters: nominal pressure: 16, 25, 32MPa, applicable temperature: 425 ℃, 450 ℃, 500 ℃, 540 ℃, mainly used in enterprises such as steel, metallurgy, power plants, and thermal power.

A shut-off valve that uses electricity as kinetic energy to achieve switching and regulation is also called an electric shut-off valve. Usually used in situations where frequent opening and closing are required to achieve large-scale centralized control. When working, the operation can be controlled by connecting to a 220VAC or 380V power supply. A control module can also be added to input control signals (4-20mADC or 1-5VDC) for adjustment and control. A handwheel can also be installed for manual control when necessary. Select different electric actuators according to different process requirements, such as switch type, signal feedback type, explosion-proof type, regulating type, etc.

638056939750100780185.jpg

Parameters of electric globe valve:

Nominal diameter: DN15-DN1500

Nominal pressure: 150LB-2500LB

Design temperature: -29 ℃ -600 ℃

Connection method: flange, weldable

Applicable media: gas, water, oil, steam, gas, corrosive fluids

Power supply voltage: AC220V, AC380V

Control mode: switch type, passive contact type, valve position signal feedback type, intelligent regulation type (input/output 4-20mA)

Other configurations: Explosion proof electric actuator with manual device (valve can be manually opened and closed without power supply)

Characteristics of high-temperature electric globe valve:

(1) The structure is simpler than gate valves, making manufacturing and maintenance more convenient.

(2) The sealing surface is not easily worn or scratched, with good sealing performance. There is no relative sliding between the valve disc and the valve body sealing surface during opening and closing, so the wear and scratches are not severe, the sealing performance is good, and the service life is long.

(3) When opening and closing, the valve disc stroke is small, so the height of the globe valve is smaller than that of the gate valve, but the structural length is longer than that of the gate valve.

(4) The opening and closing torque is large, the opening and closing are laborious, and the opening and closing time is long.

(5) The fluid resistance is high due to the tortuous medium channels inside the valve body, resulting in high fluid resistance and high power consumption.

(6) When the nominal pressure PN of the medium flow direction is ≤ 16MPa, it is generally used to flow downstream, and the medium flows upward from below the valve disc; When the nominal pressure PN is ≥ 20MPa, reverse flow is generally used, and the medium flows downwards from the valve disc to increase the sealing energy. When in use, the medium of the shut-off valve can only flow in one direction and cannot change the flow direction.

(7) The valve disc is often eroded when fully open.

638056940033079141269.jpg

Structural features:

1. The structure is simple, and manufacturing and maintenance are relatively convenient.

2. Small work schedule and short opening and closing time.

3. Good sealing performance, low friction between sealing surfaces, and long service life.

Execution standard:

1. Design specification: GB/T 1223.

2. Structural length: GB/T 12221.

3. Flange connection: JB/T 79.

4. Testing and Inspection: JB/T 9002.

5. Product identification: GB/T 12220.

6. Supply Specification: JB/T 7928

638056939546937691457.jpg

J941HElectric shut-off valve with heat dissipationMain performance parameters:

model

J41H-16C~160C

J41Y-16C~160C

J41W-16P~160P

Work pressure (MPa)

1.6~16.0

Applicable temperature (℃)

≤425

≤150

Applicable Medium

Water, steam, oil products

Weakly corrosive medium

material

Valve body, valve cover

carbon steel

Chromium nickel titanium stainless steel

valve stem

Chromium stainless steel

Chromium nickel titanium stainless steel

sealing surface

Surfacing iron-based alloy

Welding hard base alloy

body material

filler

Asbestos graphite, flexible graphite, polytetrafluoroethylene

Pressure test MPa:

Nominal pressure

1.6

2.5

4.0

6.4

10.0

16.0

strength test

2.4

3.8

6.0

9.6

15.0

24.0

Water seal test

1.8

2.8

4.4

7.4

11.0

18.0

Upper Seal Test

1.8

2.8

4.4

7.04

11.0

18.0

gas tightness test

0.4-0.7

Main component materials and performance:

Body cover wrench

valve stem

sealing surface

Gasket (ring)

filler

Working temperature ℃

Applicable Medium

WCB

2Cr13

13Cr

STL

body material

nylon

Enhanced flexible graphite

1Cr13/flexible graphite

08 Soft Steel

0Cr18Ni9Ti

OCr18Ni12Mo2Ti

flexible graphite

Enhanced flexible graphite

SFB-260

SFP-260

≤425


Water, steam, oil products

WC1

38CrMoAI

25Cr2MoV

≤450

WC6

≤540

WC9

≤570

ZGCr5Mo

≤540

ZG1Cr18Ni9Ti

1Cr18Ni9Ti

≤200

Nitric acid

ZGCr18Ni12Mo2Ti

1C18Ni12Mo2Ti

≤200

Acetic acid

l. Main appearance and connection dimensions of 1.6MPa:

电动截止阀26.jpg

1.6MPa

DN

L

D

D1

D2

b

n-Φd

H

D0

convex flange

RF

J41H

J41Y

J41W

J41F

J41N

16C

16P

16R

16I

10

130

90

60

40

14

4-Φ14

198

120

15

130

95

65

45

14

4-Φ14

218

120

20

150

105

75

55

14

4-Φ14

258

140

25

160

115

85

65

14

4-Φ14

275

140

32

180

135

100

78

16

4-Φ18

280

160

40

200

145

110

85

16

4-Φ18

330

180

50

230

160

125

100

16

4-Φ18

350

200

65

290

180

145

120

18

4-Φ18

370

280

80

310

195

160

135

20

8-Φ18

400

280

100

350

215

180

155

20

8-Φ18

415

320

125

400

245

210

185

22

8-Φ18

460

360

150

480

280

240

210

24

8-Φ23

510

450

200

600

335

295

265

26

12-Φ23

710

500

250

650

405

335

320

30

12-Φ25

786

550

300

750

460

410

375

30

12-Φ25

925

600

Main appearance and connection dimensions of 2.5MPa:

2.5MPa

DN

L

D

D1

D2

b

n-Φd

H

D0


10

130

90

60

40

16

4-Φ14

198

120

15

130

95

65

45

16

4-Φ14

218

120

20

150

105

75

55

16

4-Φ14

258

140

25

160

115

85

65

16

4-Φ14

275

140

32

180

135

100

78

18

4-Φ18

280

160

40

200

145

110

85

18

4-Φ18

330

180

50

230

160

125

100

20

4-Φ18

350

200

65

290

180

145

125

22

8-Φ18

400

280

80

310

195

160

135

22

8-Φ18

355

280

100

350

230

190

160

24

8-Φ23

415

320

125

400

270

220

188

28

8-Φ25

460

360

150

480

300

250

218

30

8-Φ25

510

450

200

600

360

310

278

34

12-Φ25

710

500

250

622

425

370

332

36

12-Φ30

786

550

300

698

485

430

390

40

16-Φ30

925

600

Main appearance and connection dimensions of 4.0MPa:

4.0MPa

DN

L

D

D1

D2

D6

b

n-Φd

H

D0

Concave convex flange

MFM

J41H

J41Y

J41W

J41N

40

40P

40R

40I

10

130

90

60

41

35

14

4-Φ14

198

120

15

130

95

65

45

40

16

4-Φ14

233

120

20

150

105

75

55

51

16

4-Φ14

295

140

25

160

115

85

65

58

16

4-Φ14

285

160

32

180

135

100

78

66

18

4-Φ18

302

160

40

200

145

110

85

76

18

4-Φ18

355

200

50

230

160

125

100

88

20

4-Φ18

373

200

65

290

180

145

120

110

22

8-Φ18

408

280

80

310

195

160

135

121

22

8-Φ18

436

280

100

350

230

190

160

150

24

8-Φ23

480

320

125

4001

270

220

188

176

28

8-Φ25

588

360

150

480

300

250

218

204

30

8-Φ25

611

400

200

600

375

320

282

260

38

12-Φ30

720

400

6.4MPa Main appearance and connection dimensions:

6.4MPa

15

170

105

75

55

40

18

4-14Φ

195

400

Concave convex flange

MFM

J41H

J41Y

J41W

J41N

64

64P

64R

64I

20

190

125

90

68

51

20

4-Φ18

228

160

25

210

135

100

78

58

22

4-Φ18

275

180

32

230

150

110

82

66

24

4-Φ23

325

200

40

260

165

125

95

76

24

4-Φ23

360

240

50

300

175

135

105

88

26

4-Φ23

410

280

65

340

200

160

130

110

28

8-Φ23

450

320

80

380

210

170

140

121

30

8-Φ23

485

360

100

430

250

200

168

150

32

8-Φ25

537

400

125

500

295

240

202

176

36

8-Φ30

631

400

150

550

340

280

240

204

38

8-Φ34

646

450

200

650

405

345

300

260

44

12-Φ34

813

500

Main appearance and connection dimensions of 10.0MPa:

10.0MPa

10

170

100

70

50

35

20

4-Φ14

198

140

Concave convex flange

MFM

J41H

J41Y

J41W

100

100P

100R

100I

15

170

105

75

55

40

20

4-Φ14

202

140

20

190

125

90

68

51

22

4-Φ18

228

160

25

210

135

100

78

58

24

4-Φ18

250

180

32

230

150

110

82

66

24

4-Φ23

326

200

40

260

165

125

95

76

26

4-Φ23

360

240

50

300

195

145

112

88

28

4-Φ25

414

280

65

340

220

170

138

110

32

8-Φ25

434

320

80

380

230

1810

148

121

34

8-Φ25

547

360

100

430

265

210

172

150

38

8-Φ30

621

400

125

500

310

250

210

176

42

8-Φ34

732

400

150

550

350

290

250

204

46

12-Φ34

840

450

To ensure the normal operation of the electric globe valve, please check whether the configuration of the electric globe valve meets the design requirements before installing a new valve. So what should be paid attention to when installing an electric shut-off valve? Next, the editor will explain it to everyone. I hope it can help you. The specific content is as follows:

638056939877292912709.jpg

1. Electric globe valve is a type of on-site instrument. The ambient temperature is -25 ℃~60 ℃, and the relative humidity is less than 95%. When installed outdoors or in high-temperature environments, waterproof and cooling measures should be taken. Stay away from the vibration source or strengthen anti vibration measures at the location of the vibration source.

2. In general, the pipeline for installing electric shut-off valves should not be too high above the ground or ground level. When the height of the pipeline exceeds 2 meters, a platform should be set up to facilitate the operation and maintenance of the handwheel.

3. Electric globe valves usually require vertical installation, and can be installed at an angle in special circumstances. If the angle is large or the valve itself is too heavy, a bracket should be used to protect the valve.

Before installing the electric shut-off valve, the pipeline should be cleaned thoroughly to remove dirt and welding slag. After installation, to ensure that there are no impurities inside the valve body, the valve should be cleaned again by opening all valves when the medium enters to prevent impurities from sticking. After using the handwheel mechanism, it should return to its original neutral position.

5. When the electric shut-off valve malfunctions or is repaired, in order to continue the production process, the electric shut-off valve should be installed on the bypass pipeline. At the same time, special attention should be paid to whether the position of the electric shut-off valve meets the process requirements.

6. The electrical components of the electric globe valve need to be installed according to the structural requirements of their respective electrical equipment. Explosion proof products need to be installed in accordance with the requirements of the electrical equipment installation regulations in explosion-proof places. When installing cables with SBH type or other 6-core or 8-core rubber sleeves, the outer diameter of the cable is about 11.3mm. During use and maintenance, it is strictly prohibited to open the maintenance cover or pry open the explosion-proof surface in explosive areas. At the same time, do not bump or scratch the explosion-proof surface during disassembly and assembly, and restore it to its original explosion-proof state after repair.

7. After disassembling and repairing the electric shut-off valve reducer, please pay attention to oil lubrication. Generally, do not disassemble, clean, or add oil to low-speed motors. After assembly, the position of the check valve matches the position of the opening indicator.

8. Electric globe valves use the valve stem to lift and drive the valve head, changing the distance between the valve disc and seat to achieve valve on/off control. Therefore, electric globe valve is a widely used chemical valve, mainly used for production management and control, suitable for pipelines such as water, steam, compressed air, etc., but not suitable for materials with different viscosities and easy crystallization.

9. Different work environments result in different work styles. When users activate the electric shut-off valve, the clutch handle needs to be in the correct position. When operating the electric shut-off valve in the control room, it is necessary to turn on the remote control button and intelligently control the valve switch through the SCADA system. When using an electric globe valve, pay attention to the valve opening/closing indication and stem position. The electric glove valve cannot be manually adjusted and can only be fully opened or fully closed. If the valve flips due to improper operation, experienced operators or maintenance personnel should manually flip it from the half circle.

10. During the operation and management of the electric globe valve, if abnormal valve sound or flashing globe valve signal is detected through the indicator light, an alarm will be triggered.

638056940417096688775.jpg

Ordering Notice:

1、 ① Product name and model ② Caliber ③ Is there any accessory for us to correctly select for you ④ Operating pressure ⑤ Temperature of the medium used.

2、 If the company's model has already been selected by the design unit, please order directly from our sales department according to the model.

3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our valve company experts will review and control them for you. If you have any questions: Please: We will do our best to provide you with high-quality service. We provide comprehensive and professional "valve system solutions" and are also willing to help users solve problems encountered in production.