CRM-STX-g Stone Chamber Clam Toxin Standard (Paralytic Shell Poison) Product Introduction
Brand: Canadian NRC Standard
CRM code(货号):CRM-CYN
English name: Saxitoxin Dihydrochloride Calibration Solution CRM
Chinese name: Stone house clam toxin standard, Paralytic shellfish toxin standard
Specifications0.5 mL /ampoule
Validity period:
If stored unopened under recommended storage conditions (storage instructions section), the centralized validity period of certified CRM is 1 year from the date of sale.
Direct ordering from the original manufacturer, quality assurance, short delivery time, and after-sales service *.
Product Description:
Saxitoxin (STX) [1] is present in marine microalgae [2] and freshwater cyanobacteria [3]. CRM-STX-g is a certified reference substance (CRM) calibration solution for STX in 0.5 mM hydrochloric acid aqueous solution, designed to assist in the identification and quantification of STX. This is an alternative calibration solution for CRM-STX-f.

Expected use:
CRM-STX-g is a certified calibration solution designed specifically for the development and accurate quantification of STX analysis methods. This concentration is suitable for preparing dilution series for calibration of liquid chromatography instruments such as pre/post column oxidation fluorescence (LC ox FLD) or liquid chromatography-mass spectrometry (LC-MS) detection, as well as for reference samples used in spiked recovery experiments.
Storage and usage instructions:
Storage instructions:
The material should be stored at a temperature of+4 ° C. Ampoules should be stored unopened.
Instructions for Use:
Before opening, each ampoule should be equilibrated to room temperature and the contents thoroughly mixed. Before use, the ampoule should be opened immediately in a pre rated market. CRM solutions should use calibrated equipment for transfer to ensure accuracy. The certification value can only be guaranteed if a sample is taken immediately after opening the ampoule to limit solvent evaporation. It is worth noting that the volume of the solution has not been certified; Only the concentration is certified. Therefore, the entire contents of the ampoule should not be diluted to a certain volume.
Repeated sampling and storage of CRM solutions after opening may affect authentication values. The user is responsible for proving that their packaging and storage procedures will not affect the certification value.
More aboutCRM-STX-g Stone Chamber Clam Toxin Standard (Paralytic Shell Poison) Please contact our company for product information.