Welcome Customer !

Membership

Help

Fujifilm and Light (Guangzhou) Trading Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Fujifilm and Light (Guangzhou) Trading Co., Ltd

  • E-mail

  • Phone

  • Address

    Room 3002, 3003, 3011, Dongshan Square, No. 69 Xianlie Middle Road, Yuexiu District, Guangzhou City

Contact Now

Apolipoprotein B-48 (ApoB-48) ELISA Kit

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Apo B-48 is a high-quality biomarker used to observe exogenous lipid transport after eating. Changes in exogenous and endogenous cholesterol can be analyzed by detecting Apo B-48 and HDL cholesterol, LDL cholesterol in the same sample. $r $nFUJIFILM Wako can provide a specific ApoB-48 ELISA kit for detecting Apo B-48.

Product Details

Apolipoprotein B-48 (ApoB-48) ELISA Kit载脂蛋白 B-48(ApoB-48)ELISA 试剂盒




Apolipoprotein B-48 (ApoB-48) is a specific structural protein of chylomicrons, which can transport exogenous lipids from food and other sources to the liver and peripheral tissues. Apo B-48 is a high-quality biomarker used to observe exogenous lipid transport after eating. Changes in exogenous and endogenous cholesterol can be analyzed by detecting Apo B-48 and HDL cholesterol, LDL cholesterol in the same sample.

FUJIFILM Wako can provide ELISA kits for specific detection of Apo B-48.



Concept of Apo B-48


Lipoprotein is a complex composed of a certain proportion of fat and protein, mainly responsible for lipid transport in the body. Its structural surface contains apolipoprotein, which plays an important role in stabilizing lipoprotein structure, activating enzymes related to lipoprotein metabolism, and binding to lipoprotein receptors on the cell surface.

Apolipoprotein B-48 (Apo B-48: Apolipoprotein B-48) is a specific structural protein of chylomicrons (Figure 1), which can transport exogenous lipids from food and other sources to the liver and peripheral tissues. Its molecular weight is 264000 kDa and structurally shares 48% homology with the amino acid sequence of apolipoprotein B-100, which exists on lipoproteins (VLDL, LDL, and HDL) that transport endogenous lipids.

Apo B-48 is a high-quality biomarker for observing exogenous lipid transport after eating. It can be analyzed for changes in exogenous and endogenous cholesterol by detecting Apo B-48 and HDL cholesterol, LDL cholesterol in the same sample1)In addition, according to reports, Apo B-48 on an empty stomach can also serve as an indicator of postprandial hyperlipidemia2), which is used to evaluate the chylomicron (CM) residues (CM residues) associated with peripheral arterial disease (PAD), cardiovascular disease, vascular endothelial injury, and atherosclerosis in the cardiovascular system.


  

载脂蛋白 B-48(ApoB-48)ELISA 试剂盒



LBIS ™ Human Apolipoprotein B-48 (ApoB-48) ELISA Kit


LBISThe ApoB-48 ELISA kit can be used to detect human apolipoprotein B-48.

This kit uses specific antibodies against apolipoprotein B-48, and the cross reactivity with apolipoprotein B-100 is lower than the detection sensitivity.

载脂蛋白 B-48(ApoB-48)ELISA 试剂盒




Antibody solid-phase well plate

1 piece

ApoB-48 standard

1 unit

buffer solution

60 mL

Biotin binding antibody solution

100 μL

Peroxidase bound streptavidin solution

100 μL

TMB solution

12 mL

Reaction termination solution

12 mL

Cleaning solution (10 x)

100 mL

Sealing film

4 pieces


















Test kit performance


Standard curve range

2.5-160 ng/mL

test object

Apo B-48

test sample

Human serum/plasma (citric acid cannot be used)

Sample detection quantity

50 μ L (diluted 100 times)

Detection Time

About 2 hours and 50 minutes

detection method

Colorimetric method (main wavelength: 450 nm/sub wavelength: 620 nm)









Example of Standard Curve


载脂蛋白 B-48(ApoB-48)ELISA 试剂盒


Human sample (fasting) detection value


sample size

average

standard deviation

N=18

4.60 μg/mL

1.54 μg/mL




The above test values are for reference only, and the actual test values may vary due to blood collection or sample storage conditions.



Changes in plasma lipoproteins during intake of fluvastatin and omega-3 fatty acids3)


Patients with type 2 diabetes and hyperlipidemia were given 80 mg of fluvastatin or 80 mg of fluvastatin and 4 g of omega-3 fatty acid, and blood samples were collected 12 h after fasting to detect apolipoprotein B-100 and apolipoprotein B-48 in the samples.


载脂蛋白 B-48(ApoB-48)ELISA 试剂盒


Changes in Apolipoprotein B-100 and Apolipoprotein B-48 from Baseline Values

Draw according to reference 3)


【result】

After taking fluvastatin and omega-3 fatty acids, there was a significant decrease in apolipoprotein B-48.



LBIS ™ Human Apolipoprotein B-48 Control Set


Apolipoprotein B-48 (Apo B-48) is a specific structural protein that exists in small intestine derived lipoprotein chylomicrons (CM) and CM residues (CM residues). CM has the function of transporting exogenous lipids from sources such as food to the liver and peripheral tissues, therefore detecting Apo B-48 is a suitable indicator for observing exogenous lipid transport after eating.

This product is LBIS ™ The precision management control kit for Human Apo B-48 ELISA Kit (298-88901) includes Low control and High control, which can be used directly after thawing. Can be used for precision management of each detection.



concentration


य की मांग (human grandchild b- 48 controltl): < 50.0 ng/ml

# toppled the enslavement Total (human grandchild b- 48 controlph): > = 70.1 ng/ml


Download product brochure: www.boppard.. cn/pdf/show/193.html



References


1. Otokozawa, S.et al.:Metabolism,58(11), 1536(2009).
Fasting and postprandial apolipoprotein B-48 levels in healthy, obese, and hyperlipidemic subjects

2. Reyes-Soffer, G.et al.:Diabetes Care,36(2), 422(2013).
Effect of combination therapy with fenofibrate and simvastatin on postprandial lipemia in the ACCORD lipid trial

3. Valdivielso, P.et al.:Cardiovasc. Diabetol.,8, 1(2009).

Omega 3 fatty acids induce a marked reduction of apolipoprotein B48 when added to fluvastatin in patients with type 2 diabetes and mixed hyperlipidemia: a preliminary report



◆ Product List


LBIS ™ Human serum apolipoprotein B-48 (ApoB-48) ELISA kit


Product Number Product Name Product Specifications
298-88901 LBIS™ Human Apo B-48 ELISA Kit
LBIS ™ Human serum apolipoprotein B-48 (ApoB-48) ELISA kit
96 tests







LBIS ™ Human apolipoprotein B-48 control kit


Product Number Product Name Product Specifications product grade
292-89009 Human ApoB-48 Control Set
ApoB-48 Control Set
10 x 2 sets Immunochemical use
298-89001 Human ApoB-48 Control Set
ApoB-48 Control Set
25 pieces x 2 sets Immunochemical use
294-89003 Human ApoB-48 Control Set
ApoB-48 Control Set
50 pieces x 2 sets Immunochemical use




Related Products


Cholesterol detection kit





Product Number Product Name Product Specifications product grade
293-93601 LabAssay™ Cholesterol
LabAssay ™ Cholesterol
500 Tests Used in cell biology
299-96501 LabAssay™ HDL- Cholesterol
LabAssay ™ HDL Cholesterol
100 Tests Used in cell biology
291-96701 LabAssay™ LDL- Cholesterol
LabAssay ™ LDL Cholesterol
100 Tests Used in cell biology





Glycerol triester detection kit



Product Number Product Name Product Specifications product grade
291-94501 LabAssay™Triglyceride
LabAssay ™ Glycerol triester detection kit
350 Tests Used in cell biology




Free Fatty Acid (NEFA) Detection Kit


Product Number Product Name Product Specifications product grade
299-94301 LabAssay ™ NEFA (FFA)
LabAssay ™ Free fatty acid detection kit
500 Tests Used in cell biology




Phospholipid detection kit


Product Number Product Name Product Specifications product grade
295-94401 LabAssay™Phospholipid
LabAssay ™ Phospholipid detection kit
500 Tests Used in cell biology