Agilent 1290 Infinity III Variable Wavelength Detector

NegotiableUpdate on 01/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Agilent 1290 Infinity III variable wavelength detector is capable of rapid analysis at data acquisition rates up to 240 Hz, achieving the highest analysis efficiency. More sample information can be collected in dual wavelength mode. Time programmable wavelength switching can provide good sensitivity and selectivity for your application.
Product Details

Agilent 1290 Infinity III Variable Wavelength DetectorCapable of rapid analysis at data acquisition rates up to 240 Hz, achieving the highest analysis efficiency. More sample information can be collected in dual wavelength mode. Time programmable wavelength switching can provide good sensitivity and selectivity for your application.

Low baseline noise and drift can achieve low detection limits, enabling reliable quantitative analysis of trace components.

Agilent 1290 Infinity III Variable Wavelength Detectorfeature

Low baseline noise and drift can achieve low detection limits, enabling reliable quantitative analysis of trace components

Dual wavelength function, providing more analyte information with each run

A data acquisition rate of up to 240 Hz can achieve up to 100% separation in ultra fast liquid chromatography

Wide linear range (upper limit>2.5 AU), capable of reliable simultaneous quantitative analysis of major compounds, by-products, and impurities

Electronic temperature control (ETC) can provide maximum baseline stability and practical sensitivity under constantly changing environmental temperature and humidity conditions

Provide automated wavelength validation using the built-in holmium oxide filter

The radio frequency identification (RFID) technology used in the circulation pool and lamp can elevate data traceability to a whole new level

Early Maintenance Feedback (EMF) continuous tracking of instrument usage (e.g. tracking lamp usage time based on user-defined limits and information types)

Use Agilent Lab Consultant software for comprehensive diagnosis, error detection, and display

Utilizing stop flow wavelength scanning for rapid wavelength optimization