Agilent 1260 Infinity III High Capacity Column Temperature Chamber

NegotiableUpdate on 01/28
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Agilent 1260 Infinity III High Capacity Column Temperature Chamber (MCT) is a constant temperature HPLC column temperature chamber that provides precise temperature control for up to four chromatography columns over a wide temperature range. It can be cooled to 10 ° C below ambient temperature; #176; C, And heated to up to 85 #176; C。
Product Details

Agilent 1260 Infinity III High Capacity Column Temperature ChamberMCT is a constant temperature HPLC column incubator that provides precise temperature control for up to four chromatography columns over a wide temperature range. It can be cooled to 10 ° C below ambient temperature and heated up to 85 ° C.

The high-pressure valve with a rated pressure of 800 bar is suitable for various applications, such as automated selection of up to four chromatography columns, sample pretreatment for analyte enrichment or matrix removal, or alternating column regeneration. The 1260 Infinity III MCT is compatible with any InfinityLab liquid chromatography series system and can also be used in conjunction with early 1260 and 1290 Infinity series modules.

Agilent 1260 Infinity III High Capacity Column Temperature Chamberfeature

Peltier cooling/heating has two independent temperature zones, ranging from 10 ° C to 85 ° C below ambient temperature, providing the highest application flexibility

Up to four 30 cm chromatography columns equipped with InfinityLab Quick Connect quick connect adapters or pre columns for high column capacity

The bio inert options of heat exchangers and InfinityLab Quick Change quick change valve heads can be used for analyzing biomolecules

A 90 ° or 180 ° door position can achieve excellent practicality, or the door can be removed to provide maximum operability

InfinityLab Quick Connect enables reproducible pre column solvent heating with quick connect heat exchangers

InfinityLab Quick Connect quick connect connector facilitates efficient, fast, and convenient column replacement

Optional valve drive, used to activate the user replaceable InfinityLab Quick Change quick change valve head, rated pressure up to 800 bar

Up to four chromatographic columns can be identified, and the type, main parameters, and injection times can be recorded to obtain traceable chromatographic column usage history