- Phone
-
Address
A038, 4th Floor, Fangda Building, No. 011 Science and Technology South 12th Road, High tech Zone Community, Yuehai Street, Nanshan District, Shenzhen
Shenzhen Chenyi Technology Co., Ltd
A038, 4th Floor, Fangda Building, No. 011 Science and Technology South 12th Road, High tech Zone Community, Yuehai Street, Nanshan District, Shenzhen
High frequency noise simulatorINS-4020-G545
Meets Japanese JIS industrial standards, with a maximum voltage of 2kV and a maximum bandwidth of 1 μ s. It has a built-in single-phase coupling decoupling network and additional options for various tests. Maximum test voltage: 2kV; compliant with Japanese JIS industrial standards; Pulse width adjustable from 50ns to 1000ns; The maximum repetition frequency can reach 2 seconds; built-in single-phase coupling decoupling network;
High frequency noise simulatorINS-4020-G545Product Features:
Simulators use floating ground generation circuits to make installation and wiring simpler;
Short circuiting the plug and changing the insertion position allows for differential/common mode switching;
The tester is equipped with a 50 Ω terminal, which does not require additional impedance and has simple wiring;
You can set the repetition cycle and phase on the host;
The simulator has output voltage and repeat cycle scanning functions, and can be set to any step;
By using the output panel, the EUT's AC connector can be directly connected to the simulator; (Optional)
The simulator can perform radiation testing on various PCB boards through various probes, using coupling clips, adapters, and can test various circuits; (Optional)
Additional coupling network can be used for testing EUT three-phase 5-wire power supply; (Optional)
Specifications:
project |
INS-4020 |
|
square wave |
pulse width |
50、100、200、250、400ns、 ± 10% combination, minimum 10ns ± 3ns |
output voltage |
0.01~2.00kV ± 10% (below 0.1kV ± 0.04kV) 10V step |
|
polarity |
Positive or negative |
|
rise time |
Below 1ns |
|
output impedance |
50 system (53.5 Ω) |
|
repetition cycle |
duration |
10ms~999ms ± 10% (1ms step) |
manual |
Output each time according to the phase setting of the line, and output once when there is no line input |
|
Line phase |
50Hz/60Hz injection phase 0~360 degrees ± 10 degrees (1 degree step) |
|
external trigger |
*EXT TRIG mode |
|
Memory capacity |
5 experiments |
|
Power capacity of the tested object (EUT) |
Single phase AC240V/DC60V 16A |
|
Power supply/power consumption |
AC100 ~ 240V 50Hz/60Hz/140VA |
|
Temperature/humidity range for use |
15 ~ 35℃. 25 ~ 75℃ |
|
Size |
(W) 430 × (H) 249 × (D) 420mm/approximately 19kg |
|
High voltage coaxial joint |
NMHV NOISEKEN specifications |
|
Attachment:
name |
model |
quantity |
description |
Pulse width setting line |
02-00013A |
8 pieces |
Replace the pulse width setting line by plugging in |
SG sets short-circuit plug |
02-00106A |
1 piece |
NMHV NOISEKEN specification plug |
Output panel |
18-00061B |
1 piece |
NMHV NOISEKEN specification panel |
power cord |
1 piece |
Single phase terminal lifting type AC240V/DC60V 16AMax |
|
Operation Manual |
1 volume |
Recommended configuration:
High frequency testing standards |
model configuration |
description |
Japanese JIS Industrial Standards |
INS-4020 |
High Frequency Noise simulator; |
ESDD |
Electrostatic experimental environment; |
Other testing options:
Non standard options |
18-00060B |
Output panel; Provide plugs for plugging in |
AT-810 |
Attenuator for waveform observation; Attenuator for observing pulse waveform |
|
CA-805B |
Coupling clip (capacitive coupling); Device for testing signal lines |
|
H2-B |
EMS probe kit; Accessories for radiation testing |


Reminder: The NOISEKEN INS-4020 high-frequency noise simulator has been discontinued. The replacement product model is INS-S220. Please visit the new product website for more detailed product information.