High frequency noise simulator INS-4020-G545

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The high-frequency noise simulator INS-4020-G545 meets the Japanese JIS industrial standard, with a high voltage of 2kV and a bandwidth of up to 1 μ s. It has a built-in single-phase coupling decoupling network and additional options for various tests. Maximum test voltage: 2kV; compliant with Japanese JIS industrial standards; Pulse width adjustable from 50ns to 1000ns; The maximum repetition frequency can reach 2 seconds; built-in single-phase coupling decoupling network; Corresponding to Nissan factory standard high-frequency noise simulator

Product Details

High frequency noise simulatorINS-4020-G545

Meets Japanese JIS industrial standards, with a maximum voltage of 2kV and a maximum bandwidth of 1 μ s. It has a built-in single-phase coupling decoupling network and additional options for various tests. Maximum test voltage: 2kV; compliant with Japanese JIS industrial standards; Pulse width adjustable from 50ns to 1000ns; The maximum repetition frequency can reach 2 seconds; built-in single-phase coupling decoupling network;

High frequency noise simulatorINS-4020-G545Product Features:

  • Simulators use floating ground generation circuits to make installation and wiring simpler;

  • Short circuiting the plug and changing the insertion position allows for differential/common mode switching;

  • The tester is equipped with a 50 Ω terminal, which does not require additional impedance and has simple wiring;

  • You can set the repetition cycle and phase on the host;

  • The simulator has output voltage and repeat cycle scanning functions, and can be set to any step;

  • By using the output panel, the EUT's AC connector can be directly connected to the simulator; (Optional)

  • The simulator can perform radiation testing on various PCB boards through various probes, using coupling clips, adapters, and can test various circuits; (Optional)

  • Additional coupling network can be used for testing EUT three-phase 5-wire power supply; (Optional)


Specifications:

project

INS-4020

square wave

pulse width

50、100、200、250、400ns、 ± 10% combination, minimum 10ns ± 3ns

output voltage

0.01~2.00kV ± 10% (below 0.1kV ± 0.04kV) 10V step

polarity

Positive or negative

rise time

Below 1ns

output impedance

50 system (53.5 Ω)

repetition cycle

duration

10ms~999ms ± 10% (1ms step)

manual

Output each time according to the phase setting of the line, and output once when there is no line input

Line phase

50Hz/60Hz injection phase 0~360 degrees ± 10 degrees (1 degree step)

external trigger

*EXT TRIG mode
Action cycle: above 10ms Pulse width: above 1ms
Input level: TTL/open circuit rectifier negative logic

Memory capacity

5 experiments

Power capacity of the tested object (EUT)

Single phase AC240V/DC60V 16A

Power supply/power consumption

AC100 ~ 240V 50Hz/60Hz/140VA

Temperature/humidity range for use

15 ~ 35℃.  25 ~ 75℃

Size

(W) 430 × (H) 249 × (D) 420mm/approximately 19kg

High voltage coaxial joint

NMHV NOISEKEN specifications


Attachment:

name

model

quantity

description

Pulse width setting line

02-00013A

8 pieces

Replace the pulse width setting line by plugging in

SG sets short-circuit plug

02-00106A

1 piece

NMHV NOISEKEN specification plug

Output panel

18-00061B

1 piece

NMHV NOISEKEN specification panel

power cord


1 piece

Single phase terminal lifting type AC240V/DC60V 16AMax

Operation Manual


1 volume



Recommended configuration:

High frequency testing standards

model configuration

description

Japanese JIS Industrial Standards

INS-4020

High Frequency Noise simulator;

ESDD

Electrostatic experimental environment;


Other testing options:

Non standard options

18-00060B

Output panel; Provide plugs for plugging in

AT-810

Attenuator for waveform observation; Attenuator for observing pulse waveform

CA-805B

Coupling clip (capacitive coupling); Device for testing signal lines

H2-B

EMS probe kit; Accessories for radiation testing


高频噪声模拟器 INS-4020-G545


高频噪声模拟器 INS-4020-G545

Reminder: The NOISEKEN INS-4020 high-frequency noise simulator has been discontinued. The replacement product model is INS-S220. Please visit the new product website for more detailed product information.