Meets the IEC61000-4-4Ed.3 standard, with a maximum voltage of 5000V and a maximum frequency of 2MHz. It can be connected to a computer to use software and achieve automated testing. Adding options can also evaluate and test the anti-interference performance of signal lines and substrates. Maximum test voltage: 4.8kV; maximum test frequency: 2MHz; Built in single-phase coupling decoupling network; PE line -10A current
Electric Fast Transient Pulse Group SimulatorFNS-AX3-N1633Product features:
The simulator program has a self checking function, which makes the test results more reliable;
By using optional components, differential modeling tests can be conducted to simulate the interference sources that actually cause faults; (Optional)
The use of three color indicator lights at the beginning of the test ensures safer testing; (Optional)
EUT plugs can be connected to corresponding socket box sockets; (Optional)
The new simulator has a smaller size and is easy to transport;
A simple and clear panel can reduce errors when connecting EUT;
The operation screen of the LCD panel has a clearer operating experience, and the multi language function in the program can meet the needs of different languages;
You can use control software corresponding to AndroidTM (tablet) and Windows (computer) to operate the simulator; (Optional)
The software has multiple functions such as "correction date notification" and "help"; (Only available on Android/Windows software)
The maximum output voltage of the simulator can reach 5kV, and the maximum pulse frequency can reach 2MHz, which can perform tests far beyond the standard test level.
CDN capacity has reached single ▪ The three-phase model AC600V/63A can meet higher EUT power capacity requirements.
Use high-capacity CDN (100A or 150A) to meet higher testing requirements of EUT; (Optional)
The anti-interference tolerance of signal lines and substrates can be evaluated and tested using coupling clips and EMS probe kits. (Optional)
generatorSpecifications:
project |
Specification and Function |
output voltage |
200~5000V 10V step |
polarity |
Positive or negative, pulse group polarity can be continuously reversed |
pulse frequency |
0.1kHz ~ 2000kHz 0.1kHz~1kHz/0.01kHz Step accuracy ± 5% 1.0kHz~10kHz/0.1kHz step accuracy ± 5% 10kHz~100kHz/1kHz Step accuracy ± 5% 100kHz~1000kHz/10kHz Step accuracy ± 5% 1000kHz~2000kHz/100kHz Step accuracy ± 10% When the pulse is continuously output, there is a limit to the voltage |
pulse count |
1~1000/1 step Set limit: Within 1 pulse group, 1 pulse/ms (pulse frequency above 1kHz) |
Pulse group time |
Calculation method: (number of pulses)/(pulse frequency) The adjustable range of pulse group time for direct setting: 0.01~999ms |
Pulse group period |
10~1000ms ± 10% 10ms step (maximum 500ms during polarity reversal) |
Polarity reversal function |
Each pulse group cycle has a positive/negative polarity, alternating between outputs Setting conditions: The pulse group period is more than 500ms, and the pulse group rest time [(pulse group period) - (pulse group time)] is more than 100ms. Maximum test time: 10 minutes |
Pulse continuous output |
0 ~ 1000V 10kHz 以下 0 ~ 2000V 4kHz 以下 0 ~ 5000V 1kHz 以下 The maximum test time for all experiments is 10 minutes |
frequency modulation |
Continuous frequency transition from the set frequency to approximately -10%. A triangular wave with a modulation frequency of approximately 20Hz |
external trigger |
When an external input signal is received, the simulator is synchronously triggered to output one pulse train. The input specification for the trigger signal is Hi (+5V) → Lo (0V), and one pulse train is output |
|
Pulse waveform At 50 Ω load |
Pulse peak voltage: (set voltage/2) ± 10% Rise time: 5ns ± 30% Pulse width: 50ns ± 30% |
|
Pulse waveform At 1K Ω load |
Pulse peak voltage: (set voltage x 0.95) ± 20% Rise time: 5ns ± 30% Pulse width: 35~150ns |
DC blocking inductor |
10nF ±20% |
CDNSpecifications:
project |
Specification and Function |
power capacity |
Three phase AC600V/63A, DC125V/63A (but N/PE is 10A) |
Shi Jiaxiang |
L1/L2/L3/N/PE can be single-phase, full phase, or each phase separately |
coupling mode |
Common mode usage options allow for differential mode coupling |
Input/output mode |
6mm safety socket |
coupling capacitor |
33nF |
Output waveform specifications |
Pulse peak voltage: (set voltage)/2 ± 10% Rise time: 5.5 ns ± 1.5 ns Pulse width: 45 ns ± 15 ns (Set voltage ± 4000V; indicators for frequency 5kHz~100kHz) |
Input residual voltage |
Set the pulse voltage to below 10% (Indicator when EUT power cord input is 50 Ω terminal and power cord output is open circuit) |
AC power line synchronization |
Can be set synchronously or asynchronously Set phase angle: 0~360 °± 10 ° 1 ° step Voltage can be set during synchronization: from AC85V to rated voltage, phase as reference: between L1-N2 |
Other specifications:
project |
Specification and Function |
Emergency stop |
Press switch (test stop, EUT power cord OFF) |
EUT FAIL function |
An external FAIL signal (Hi → Lo) was detected during the experiment |
|
FAIL signal specifications VLO: 0V, VHI:+5V When the FALL signal action is detected, the test can be temporarily stopped FAIL input is 3 channels | |
external interface |
REMOTE: Fiber optic communication interface, connected when controlled by an external PC CDN I/F: CDN control interface, connected when using an external CDN INDICATOR: Connect warning lights and display lights for use EUT FAIL INPUT: Temporarily tested for use in case of EUT malfunction (External CDN and warning lights are optional) |
working environment |
Temperature range of 15~35 ℃ Relative humidity 25~75% |
External dimensions/weight |
W430 × H199 × D370mm (excluding protrusions)/approximately 22 kg |
drive power supply |
AC100~240V ± 10% 50/60Hz, approximately 120VA |
Attachment:
name |
Specification/Quantity |
Operation Manual |
1 set |
Factory Verification Report |
1 copy |
power cord |
1 piece |
SG cable |
1 piece |
Corresponding standards and configurations:
Electrical Fast Transient Pulse Group Testing Standard |
model configuration |
description |
IEC61000-4-4 Ed.3 |
FNS-AX4-B63 |
Test host; |
ESDD |
Pulse group test environment; |
|
15-00012A |
Coupling clip; Device for testing signal lines (optional) |
|
00-00017A |
Attenuator for waveform observation; Matching impedance 50 Ω, 40dB |
|
00-00018A |
Attenuator for waveform observation; Matching impedance 1000 Ω, 60dB |