Welcome Customer !

Membership

Help

Changzhou Jintan Kexing Instrument Factory
Custom manufacturer

Main Products:

instrumentb2b>Products

Changzhou Jintan Kexing Instrument Factory

  • E-mail

    kexing@jtkxyq.com

  • Phone

    13961267651

  • Address

    No. 25, Fenghuang Economic Industrial Park, Jintan District, Changzhou City

Contact Now

vacuum drying oven

NegotiableUpdate on 12/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Vacuum drying oven is suitable for scientific research, medical treatment, factories and mining enterprises to dry and heat treat items under vacuum conditions. Heating and drying items under vacuum conditions has several advantages: 1. It can lower the drying temperature (low pressure, low temperature). 2. It can prevent some items from oxidizing when heated. $r$n3、 Avoid heating the air to kill biological cells. $r$n4、 Dust free particle damage.
Product Details

1、 Scope of application of DZF-6050 vacuum drying oven

vacuum drying ovenSuitable for scientific research, medical, industrial and mining enterprises to dry and heat treat items under vacuum conditions. Heating and drying items under vacuum conditions has several advantages:

  1. Can lower the drying temperature (low pressure, low temperature)

  2. Avoid heating certain items to prevent oxidation.

  3. Avoid heating the air to kill biological cells.

  4. Dust free particle damage.

    2、 Main technical indicators

Model number

6050

Power supply

220V 50Hz

power consumption

1000W

ambient temperature

+5~40℃

Temperature control range

50~250

temperature resolution

0.1

temperature fluctuation

±1

真 空 度

133pa

Studio materials

1Cr18N19T1

studio dimensions

415×345×370

(mm)

3、 Overview of DZF-6050 Vacuum Drying Cabinet Structure:

vacuum drying ovenThe appearance is horizontal, the workshop is square shaped and equipped with shelves, with a large capacity for use. The all glass exterior door allows for clear observation, and the box body is made of08FHigh quality steel plate spray coating manufacturing.

vacuum drying ovenadopt12mmThe above fully tempered glass doors are equipped with adjustment devices on the door frames, which can adjust the tightness of the box door closure. A heat-resistant silicone rubber sealing ring is installed between the studio and the glass door to ensure the sealing between the door and the studio.

All control components, instruments, and valve handles are installed on the panel for easy use. They are controlled by electronic sensing amplification circuits and have digital display of indoor temperature, with accurate temperature control and high precision.

4、 Installation and debugging:

1Installation

vacuum drying ovenIt should be placed indoors with good ventilation conditions, and flammable and explosive materials should not be placed around it.

2Debugging

① Close the box door and tighten the handle to close the vent valve.

② Connect the air duct on the side of the vacuum box to the vacuum pump with vacuum rubber, turn on the power of the vacuum pump, and open the vacuum valve to start pumping. When the vacuum gauge reading reaches-0.06MpaWhen the vacuum valve and vacuum pump power are turned off, the box is in a vacuum state. If there is no heating function, the vacuum box debugging is completed.

③ Connect the power supply of the vacuum box, turn the power switch to the "on" position for about 7 seconds, and the temperature inside the box will be displayed on the temperature controller. The lower part is the set temperature. Press the ↑↓ keys once, and the upper row will display SP. Press the ▲ or ▼ keys again to make the lower row display the desired set temperature. Press the ↑↓ keys again, and the upper row will display ST (press the ▲ or ▼ keys to make the lower row display the desired timing time. When ST is set to 0, the instrument will cancel the timing function. When ST is not set to 0, the instrument will have the timing function. Under normal circumstances, there is no need to set a time. This time is the timer for the machine to work, and it will be turned off without any restart function. )Press the ↑↓ keys again to return to standard mode. The temperature controller setting is complete and the instrument can work normally. Generally, after heating for 90 minutes, the temperature control enters a constant temperature state.

5、 Product usage instructions:

1. Put the items that need to be dried into the vacuum box, close the box door, close the vent valve, turn on the vacuum pump, connect the vacuum pump to extract air, and achieve the required vacuum degree inside the box. Close the vacuum valve and turn off the power supply of the vacuum pump.

2. Connect the power supply of the vacuum box, select the desired set temperature, and the temperature inside the box will start to rise. When the temperature inside the box approaches the set value, the heating indicator will flash on and off, and the vacuum box will be in working condition. Turn off the power switch according to the different drying times required for different items.

3. After the drying is completed, the power should be turned off first, the vent valve should be rotated, the vacuum inside the box should be released, and the box door should be opened to remove the items (when opening the box, due to the deformation of the sealing ring and glass door due to the tight suction, after releasing the vacuum, wait for a moment for the sealing ring to return to its original shape before opening the box door).

6、 Attention:

1. The outer shell of the vacuum box must be effectively grounded to ensure safe use.

2. When the vacuum box does not require continuous pumping, the vacuum valve should be closed first, and then the power supply of the vacuum pump motor should be turned off, otherwise the vacuum pump oil should be poured back into the box.

3. When taking out processed items, they must wait for the temperature to cool before being placed into the air.The drying oven should be placed indoors with good ventilation conditions, and flammable and explosive materials should not be placed around it or inside the box,Do not dry flammable and explosive materials.

4. It is best to connect a filter between the vacuum box and the vacuum pump to prevent humid and warm gases from entering the vacuum pump.

5. Do not open the control panel unless necessary to avoid damaging the electrical system.

7、 Product maintenance and upkeep:

1. The vacuum box should be kept clean regularly, and the glass of the box door should be tested with a soft cotton cloth. Avoid wiping with reactive chemical solutions to prevent chemical reactions and scratches on the glass.

2. If the vacuum box is not used for a long time, neutral grease or Vaseline should be applied to the electroplating to prevent corrosion, and a plastic film dust cover should be placed in a dry room to prevent electrical components from being affected by moisture and affecting use.

4Electrical schematic diagram


原理图.png


5DZF-6050 vacuum drying ovenFault handling

phenomenon

reason

process

1No power supply

1The plug is not properly inserted or disconnected

1Insert the plug or connect the wire properly

2Open circuit of fuse

2Replace the fuse

2The temperature inside the box rises

1Set the temperature to low

1Adjust the set temperature

2The electric heater is broken

2Replace the electric heater

3The temperature controller is broken

3Replace the temperature controller

4The temperature sensor is loose

4Tighten the sensor nut

3There is a large error between the set temperature and the temperature inside the box

1The temperature sensor is faulty

1The temperature sensor is faulty when replacing it

2Set the temperature adjustment potentiometer accurately

2Adjust and fine tune the potentiometer

4The vacuum level cannot be reached

1The vent valve on the panel is not closed

1Close the vent valve

2The vacuum valve on the panel is not open

2Open the vacuum valve

3The vacuum pump suction pipe is not properly connected

3Connect the pipeline properly

4The vacuum pump is broken

4Replace the vacuum pump

5The box door is not tightly closed

5Close the box door tightly

6The rubber sealing ring of the box door is damaged

6Replace the sealing ring of the box door

7The vacuum gauge on the panel is broken

7Replace the vacuum gauge, it's broken

Packing list

serial number

category

name

unit

quantity

Remarks

1

document

Instruction Manual

copy

1


2

document

Packing List

copy

1


3

document

Certificate of Conformity

copy

1


4

document

Fuse core

only

2