Flame photometer

NegotiableUpdate on 07/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

A flame photometer uses a flame as an excitation light source to excite the atoms of the element being measured. A photoelectric detection system is used to measure the characteristic radiation intensity emitted by the excited element, thereby performing quantitative analysis of the element. The flame photometry method is a method of measuring the content of certain elements that emit light of a certain wavelength after being excited by a flame, based on the intensity of the emitted light. Commonly used in the field of spectroscopic methods for determining alkali metals, alkaline earth metals, and other elements.

Product Details

Flame photometerInstrument features and functions

Simultaneously detect three elements (potassium, sodium, lithium, calcium, and barium), and display the test results of all three elements. Alternatively, two elements or one element can be tested simultaneously according to the selection, and the results can be displayed separately


The instrument can linearize option elements


Digital key operation, large screen LCD display, simultaneously displaying multiple sets of data


Realize fully automatic injection, no need for manual injection, accurate and reliable injection volume, easy operation


Excellent water sealing performance effectively prevents unnecessary damage caused by gas backflow


Automatic shutdown protection, effectively protecting user safety during use


Easy to achieve automatic ignition operation, safe and easy to operate


Automatic storage of test results



Flame photometer instrument indicators

Injection rate

0-50ml/min

test scope

0-10000 ppm (depending on different elements)

repetitiveness

≤1%

detection limit

0.01ppm

Time stability

Less than 10 seconds (after the sample enters the flame for combustion)

Drift type

≤ 2% (after preheating)

linear

2%

Result Storage

Automatic storage

size

385*335*520mm

weight

11kg

Technical indicators and parameters

AA-3300F

host

light source

Element hollow cathode lamp

lamp holder

Three lamp holders

Lamp current

Dual circuit steady current power supply

optical system

1800item/mmImported grating

device

C-Ttype

wavelength range

190900nmAutomatic wavelength scanning and peak searching

Wavelength accuracy

±0.1nm

wavelength repeatability

0.1nm

Spectral bandwidth

0.1,0.2,0.4,1.0,2.0Five speed automatic switching

Baseline Drift

0.004A/30min

Range of absorbance

0.0012.000Abs0.00012.0000Abs

detector

High sensitivity imported photomultiplier tube

Background correction

Background correction of deuterium hollow cathode lamp

Flame system

Burning head

All titanium combustion head,0.6mm*100mmTitanium Steel