Dual beam large screen UV visible spectrophotometerProduct Features
◆ 1200/mm high-performance imported grating
The instrument adopts a 16mm thick optical base and a suspended optical system design, which is solid and reliable, ensuring that all parameters meet high standards
The instrument adopts modular design, with distinct functional areas for easy identification and maintenance
◆ Adopting a 320 * 240 bit 6-inch large screen LED backlit colorful LCD display
◆ Adopting a sine screw structure, with a unique structure and high precision
◆ Adopting a professionally optimized circuit system, low consumption and energy saving, the service life of the lamp source can be extended by one-third
Dual mode operation for host testing and software testing, with * functionality and easy selection
◆ Adopting a classic optical path design, the optical path endpoint has strong energy and high resolution, and the instrument is compact in size
The instrument adopts a micro signal processing system to accurately process photoelectric conversion, electrical signal and digital signal conversion
◆ Unique air circulation system, relatively balanced internal temperature of the instrument, ensuring stable working environment of internal components of the instrument
◆ Large sample room, capable of accommodating 5-100mm colorimetric dishes, flexible expandability, supporting various accessory accessories required for testing
Design of flange base deuterium lamp and socket tungsten lamp, with no optical debugging required for lamp replacement
◆ Fully sealed structure and all optical mirrors have SiO2 protective film, which comprehensively reduces the influence of external gases and environment on optical components
◆ Adopting a digital touch film keyboard, it is convenient for users to input information such as wavelength, concentration, time, etc
◆ Standard configuration of Yuanxi Company's spectral scanning software. When operated online, it can not only achieve all testing functions of the host, but also more advanced data processing functions, and enable unlimited data storage
System functions
◆Storage function: The host can directly store test data, standard curves, graphs, etc., which can be called at any time according to the name, and can be powered off to maintain; Storing data, curves, and graphs can be directly opened, read, edited, printed, etc. on the PC client
Printing function: It can directly connect to a printer to print test data, curves, and graphs
◆ Online function: Using a USB data port, online operations can be easily achieved through software
Self check function: Power on self-test of key parameters and main components, and can recalibrate the system to ensure that the instrument always operates under normal system configuration
Self calibration function: The instrument has wavelength calibration and dark current calibration functions, which can eliminate deviations caused by long-term use and ensure the accuracy of instrument measurements
Other system functions: wavelength positioning, printer settings, light source switch, automatic light source switching settings, light source time recording, time settings, wavelength verification, photometric verification, buzzer switch, factory reset settings, etc
Test function
Basic functions: Measurement functions for transmittance, absorbance, concentration, energy, etc. Single point method for testing sample concentration, multiple concentration units can be selected, and concentration units can be customized
Standard curve: A standard curve can be established through single point sampling or multi-point sampling, and the concentration of the sample can be measured using the newly created standard curve. You can choose from first-order linear zero crossing fitting, first-order linear fitting, second-order fitting, third-order fitting methods, and three calibration methods (single wavelength method, equal absorption point dual wavelength method, and three-point method)
◆ Coefficient method: Sample concentration can be determined by directly inputting the coefficients of the curve equation. Standard curves, standard sample parameters, measurement time, and other information can be stored and printed for easy archiving and retrieval
Spectral scanning: Scanning intervals are available in six levels: 0.1nm, 0.2nm, 0.5nm, 1.0nm, 2.0nm, and 5.0nm; There are three scanning speedsGear selection, high, medium, and low speeds; Scan from high wavelength to low wavelength, and after the scan is completed, the instrument returns to high wavelength to reduce the impact on UV sensitive samples; The graph can be enlarged, reduced, smoothed, and processed accordingly; Can print and retrieve peak values, and store and call graphs
◆Dynamics testing: Time scan of the sample at a fixed wavelength and calculation of reaction rate (Δ A/min). Delay time, running time, sampling time interval, etc. can be set, with sampling time intervals of 0.5s, 1.0s, 2.0s, 5.0s, 10s, 30s, and 1min, and testing time up to 9 hours
◆Multi wavelength testing: It can test the absorbance and transmittance values of a test sample at multiple wavelength points. Up to 10 different wavelengths can be set, and the test results can be stored and retrieved
DNA/protein testing: used for quantitative analysis of DNA and proteins, as well as rapid purity testing, which can directly display concentration and ratio;
Dual beam large screen UV visible spectrophotometerInstrument specifications
| model | UV-6100 |
| wavelength range | 190-1100nm |
| Spectral bandwidth | 1.8nm |
| Wavelength accuracy | ±0.1nm@656.1nm,±0.3nm |
| wavelength repeatability | ≤0.1nm |
| Wavelength setting | Automatic wavelength setting, wavelength resolution of 0.1nm |
| Photometric accuracy | ±0.2%T(0-100%T) ±0.002Abs(0-0.5Abs) ±0.004Abs(0.5-1.0Abs) |
| Photometric repeatability | ≤0.1%T(0-100%T) ≤0.001Abs(0-0.5Abs) ≤0.002Abs(0.5-1Abs) |
| stray light | ≤0.05%T |
| stability | ± 0.0005A/h (at 500nm) |
| Baseline Straightness | ±0.001A |
| noise level | ±0.0004A |
| Luminous range | 0-200%T、-4.0-4.0A、0-9999C |
| Metering Mode | Transmittance T, absorbance A, concentration C, energy E |
| scanning speed | Three adjustable speeds: high, medium, and low |
| keyboard | Digital touch film button |
| data output | USB port |
| Print output | Parallel portMicro printers; PC printer (for online use) |
| display system | 320 * 240 position arrayhighlight6-inch LCD |
| detector | Imported silicon photodiode |
| light source | Imported long-life tungsten lamps and deuterium lamps |