Dual beam UV visible spectrophotometer

NegotiableUpdate on 07/10
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The dual beam UV visible spectrophotometer Q8 is carefully selected with high-quality components and comfortable color matching. Starting from the research and development concepts of practicality, universality, stability, flexibility, etc., it is ingeniously crafted to reduce background interference, avoid system errors, improve resolution, and reshape the UV visible spectrophotometer.

Product Details

Instrument features and functions

1. Technical features

C-T type dual beam optical structure

Dual monochromator, aberration correction type Chenier Turner deviceThe C-T dual beam optical structure not only solves the problems of stray light and severe secondary diffraction caused by traditional optical paths, but also compensates for coma, which is superior to0.00002%TThe ultra-low level of stray light is the choice for high-resolution spectrometers

In order to obtain highly reproducible and accurate results from a large number of applications, all optical system lenses are coated with high-quality coatingsMaster holographic gratingThe density of UV visible grating lines is1300 pieces/mm; using a four zone segmented fan-shaped signal collection chopper with *, during the operation of the chopper, the signals of the sample and reference are separately separated and corrected by their respective black zone signals, ensuring the most accurate signals of the sample and reference are obtained each time;

This system can reduce the impact of energy drift from the light source and also minimize the effects of temperature changes on solution density and refractive index;

Sensitive detection

High quality photomultiplier tube configuration, wide gain range, fast response, high stability, especially suitable for detecting weak radiation energy;

The dark current determines the maximum sensitivity of the photomultiplier tube and limits its lower limit for detecting weak light signals,Q series unique dark current automatic correction technology, real-time deduction of dark current, sensitive response to weak light signals;

Adjustable bandwidth

The continuous adjustable spectral bandwidth has great advantages in practical testing0.1nm~5nm continuously adjustable, with a variable interval of 0.1nm, to meet different user needs; Especially for testing samples with sharp absorption peaks;

Multi functional testing

The large sample chamber, which is easy to remove and place, can accommodate more sample accessories. Special accessories such as automatic eight cell, multifunctional automatic sampler, constant temperature cell holder, optical integrating sphere, mirror reflection attachment, variable optical path sample holder, and variable angle solid sample holder have expanded the application range of the instrument, meeting the testing needs of both classic and personalized samples;

The instrument has a high degree of automation and can be configuredThe 100 bit multifunctional automatic sampler is more convenient for users to achieve various automated control operations. Through software control, the multifunctional automatic sampler can be positioned, reset, injected, cleaned, etc;

workmanship

The shell adopts precision injection molding technology, with high dimensional accuracy, isolation from environmental light interference, and can maintain long-term dimensional stability. The rigidity is strengthened, and the instrument is more durable;

Independent modular design, socket type deuterium and tungsten lamp units, light replacement without optical debugging, and easier instrument maintenance; 、

Independent lamp room design, no need to disassemble other module casings for lamp replacement, convenient and flexible;

The design of the optical base adopts computer simulation analysis and optimization, and the optical path system does not deviate even when tested in the vehicle environment;

Energy-saving and environmental protection

Exquisite structural design, optimized optical path structure, concentrated installation space32%, the maximum external size of the machine shall not exceed 550mm;

Built in cooling fan achieves thermal balance faster and saves energy10%, strong optical stability;

2. Software functions

User management interface

Allow administrators to create new users and manage permissions;

Each user logs in to the operating platform with their corresponding account and password;

Operators can be upgraded to administrators as needed;

Log management interface

Daily operation records can be automatically recorded;

Administrators can retrieve the log content of a specified time period according to their needs, and can also export and save the logs in the corresponding format;

Measurement function interface

The analysis software can achieve measurement functions such as photometric measurement, quantitative measurement, spectral scanning, dynamic analysis, etc., and also has * data processing capabilities.

The spectral scanning interface has0.025 nm/0.05 nm/0.1 nm/0.2 nm/0.5 nm/1 nm/2 nm/5 nm Eight scanning intervals are available, four scanning speeds are available, and multiple measurement modes (Abs, T%, E or R%) are covered. Users can perform peak valley retrieval and extract directional data according to their needs;

The photometric measurement interface allows users to measure absorbance, transmittance, reflectance, or energy at a fixed wavelength;

The time scanning interface allows users to perform dynamic analysis, customize the scanning wavelength range (wavelength starting and ending points), scanning interval, and measurement mode;

Quantitative analysis interface system providedmg/l、ng/ml、ng/ml、mg/ml、mMultiple concentration units such as g/ml, mg/l, ppb, ppm, mol/l are available to meet the testing requirements of various standards or pharmacopoeias;

Measurement data can be automatically saved to the system disk, and users can also save files to designated folders to avoid data loss caused by incorrect operations;

It can be directly connected to a printer for report printing and supports report preview;

followGLP/GMP standards facilitate user management, logging, and data tracking functions;

Instrument specifications

model

Q-8P

optical system

dual beam

detector

Photomultiplier tube(PMT

Calibration light source

Mercury lamp, calibrated for wavelength to ensure more accurate test results

wavelength range

185nm-900nm (optional integrating sphere and near-infrared receiver up to 1400nm)

Spectral bandwidth

0.1nm-5nm (continuously adjustable at intervals of 0.1nm)

Wavelength indication error

±0.1nm

Transmittance indication error

±0.2%T

stray light

≤0.00002%T

Baseline Straightness

±0.0004A(200-860nm)

stability

≤0.0002A/h

Luminous range

-9~9A, 0-9999C record range -10~10A