Zebron ZB-5ms gas chromatography column

NegotiableUpdate on 05/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Zebron ZB-5ms gas chromatography column: designed specifically for GC-MS with ultra-low loss performance. Aromatic matrix technology (AMT) provides a highly stable aromatic stationary phase, enhancing the separation of polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic compounds

Product Details

Zebron ZB-5ms gas chromatography column

Specially designed for GC-MS with ultra-low loss performance

Aromatic Matrix Technology (AMT): Provides highly stable aromatic stationary phases to enhance the separation of polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic compounds

Ultra low loss (MS certification): Especially suitable for high-sensitivity analysis using GC-MS

Analyzing semi volatile compounds, PAHs, or PBDEs? Please check the ZB-SEMIVOLATILES dedicated column

Do you need a lower loss chromatography column suitable for GC-MS? Please check Zebron-ZB-5PLUS

Recommended application areas

Acids, alkaloids, amines, dioxins, drugs, EPA methods (such as 525610, 6258100), essential oils, essence, fatty acid methyl esters (FAMEs), halohydrocarbons, PCBs/Aroclors, pesticides/herbicides, phenols, residual solvents, semi volatiles, and solvent impurities.

Instructions:

ZB-5ms: Column model, where "ms" represents specifically designed for mass spectrometry detectors.

Low Bleed: Refers to the difficulty of the chromatographic column stationary phase degrading into the detector at high temperatures, which is crucial for improving the signal-to-noise ratio of mass spectrometry.

EPA Method: The referenced number is the standard analytical method of the United States Environmental Protection Agency.

5% phenyl arylene/95% dimethylpolysiloxane stationary phase chromatography column

brandThe original chromatographic column model that can be replaced

Agilent ® (Agilent)DB®-5ms

DB-5.625

DB-5ms EVDX

CP-Sil 8 CB MS

VF-5ms

Restek®Rtx®-5Sil MS

Rxi®-5Sil MS

SGE®SLB®-5ms

5% phenyl arylene stationary phase

Improve the separation efficiency of aromatic analytes

Provide standard, inert, and application specific types

Can replace 5% phenyl arylene/95% dimethyl polysiloxane stationary phases from Agilent, Restek, Supelco, and other manufacturers

1、 Product Core Features

feature dimensionspecific descriptionTechnical Advantage Explanation

Fixed phase composition5% phenyl arylene/95% dimethyl polysiloxaneNon polar stationary phase is one of the commonly used and classic stationary phases in gas chromatography.

Core Technology: Arylene Matrix Technology ™ (Aromatic Matrix Technology)By embedding aromatic groups in the polymer backbone, the thermal stability and durability of the stationary phase have been improved.

Loss characteristicsUltra low churn (MS Certified)Verified by mass spectrometry, the stationary phase is not easily degraded at high temperatures, ensuring high signal-to-noise ratio and sensitivity for mass spectrometry detection, making it highly suitable for high-sensitivity analysis.

Separation performanceEnhance the separation of aromatic compoundsThanks to aromatic technology, it has excellent separation efficiency for polycyclic aromatic hydrocarbons (PAHs) and polycyclic aromatic compounds.

The application range of ZB-5ms is very wide, covering almost most of the conventional and specific fields of GC-MS analysis, especially suitable for the detection of the following analytes:

Environmental testing: Follow EPA methods (such as 525610, 6258100) to analyze dioxins, semi volatile compounds, pesticides/herbicides, polychlorinated biphenyls (PCBs), etc.

Food and essence: analysis of essential oil, essence and flavor, fatty acid methyl esters (FAMEs).

Pharmaceutical and Toxicology: Detection of drugs, alkaloids, and residual solvents.

Industry and Chemicals: Determination of acids, amines, phenols, halogenated hydrocarbons, and solvent impurities.

Determination of Dexmedetomidine and Its Metabolites in Human Serum by GC-MS Method

Determination of 16 Polycyclic Aromatic Hydrocarbons (PAHs) in Soil by Gas Chromatography Mass Spectrometry

Zebron ZB-5ms gas chromatography column

Zebron ZB-5MS Gas Chromatography Column Part Number and Specification List

Part NumberProduct DescriptionLength (m) Inner diameter (mm) Film thickness (µ m)remark

7CB-G010-02Zebron ZB-5MS, GC Cap. Column100.100.10standard

7CD-G010-08Zebron ZB-5MS, GC Cap. Column100.180.18standard

7DE-G010-14Zebron ZB-5MS, GC Cap. Column120.200.33standard

7EG-G010-11Zebron ZB-5MS, GC Cap. Column150.250.25standard

7EG-G010-11-GGCZebron ZB-5MS w/GUARDIAN150.250.25Including a 10m protective column

7FD-G010-08Zebron ZB-5MS, GC Cap. Column200.180.18standard

7FD-G010-51Zebron ZB-5MS, GC Cap. Column200.180.32standard

7GE-G010-14Zebron ZB-5MS, GC Cap. Column250.200.33standard

7HG-G010-11Zebron ZB-5MS, GC Cap. Column300.250.25standard

7HG-G010-11-BZebron ZB-5MS, 5-in Cage300.250.255-inch bracket

7HG-G010-11-GGAZebron ZB-5MS w/GUARDIAN300.250.25Including 5m protective column

7HG-G010-11-GGCZebron ZB-5MS w/GUARDIAN300.250.25Including a 10m protective column

7HG-G010-17Zebron ZB-5MS, GC Cap. Column300.250.50standard

7HG-G010-22Zebron ZB-5MS, GC Cap. Column300.251.00standard

7HG-G010-22-BZebron ZB-5MS, 5-in Cage300.251.005-inch bracket

7HM-G010-11Zebron ZB-5MS, GC Cap. Column300.320.25standard

7HM-G010-11-GGAZebron ZB-5MS w/GUARDIAN300.320.25Including 5m protective column

7HM-G010-17Zebron ZB-5MS, GC Cap. Column300.320.50standard

7HM-G010-22Zebron ZB-5MS, GC Cap. Column300.321.00standard

7HM-G010-22-GGAZebron ZB-5MS w/GUARDIAN300.321.00Including 5m protective column

7JE-G010-14Zebron ZB-5MS, GC Cap. Column500.200.33standard

7KG-G010-02Zebron ZB-5MS, GC Cap. Column600.250.10standard

7KG-G010-11Zebron ZB-5MS, GC Cap. Column600.250.25standard

7KG-G010-11-GGAZebron ZB-5MS w/GUARDIAN600.250.25Including 5m protective column

7KM-G010-11Zebron ZB-5MS, GC Cap. Column600.320.25standard

Selection Guide

Standard type: Conventional analysis.

W/GUARDIAN (including protective column): A certain length of protective column (Guardian) is integrated at the front end of the chromatographic column, which is used to capture non-volatile and polluting components, prolong the service life of the chromatographic column, without the need for additional connectors.

5-in Cage (5-inch bracket): Suitable for specific instruments (such as some Agilent GCs), this cage bracket specification defaults to standard size and is designed to accommodate 5-inch diameter column temperature chambers.

If you need to screen models with specific lengths or film thicknesses, feel free to let me know at any time