Measurement specifications: Range0-600mmThe coaxial probe design achieves measurement accuracy of * * ± 2mm * *, repeatability of ± 1mm, resolution of 0.1mm, and response speed of ≤ 0.2s, meeting the requirements of high-precision and fast measurement.
Adaptation to working conditions: Working temperatureRoom temperature 50 ℃Process pressure0.007-0.12MPa(Under normal pressure and slightly positive pressure conditions), it is suitable for liquid level monitoring in most conventional liquid storage tanks, reaction vessels, and buffer tanks.
Electrical Characteristics: Power supply24VDC(± 10% fluctuation compatible), two-wire wiring design, power consumption as low as ≤ 22.5mA; signal output4-20mA analog current+HART digital communicationSupports remote debugging, parameter configuration, fault diagnosis, and is compatible with mainstream control systems such as DCS and PLC.
process connection: AdoptingDN50 PN10 RF 304 stainless steel flangeConnection: Made of 304 material, it has excellent corrosion resistance and mechanical strength. The RF protruding flange seal is reliable and suitable for installation in atmospheric pressure vessels. It is easy to install and has strong sealing performance.
Structural configurationTop mounted installation, coaxial probe (length compatible with 600mm range), probe material 304 stainless steel, wear-resistant and resistant to medium corrosion; equipOn site LCD display moduleIt can display real-time parameters such as liquid level percentage, current value, temperature, and fault codes, and can be debugged and data viewed on site without the need for external equipment.
protective performance: Shell protection levelIP67Dustproof, waterproof, corrosion-resistant, suitable for indoor and outdoor industrial environments; No mechanical movable parts, maintenance free design, with a service life of over 10 years.
Accurate and stable measurement: The coaxial probe precisely restricts the microwave transmission, eliminates the interference of steam, foam, dust, stirring disturbance and other working conditions, and the measurement is not affected by the change of medium density, viscosity, conductivity, and can still output signals stably in low dielectric constant media (such as diesel, toluene). Designed with a small range of 600mm and an accuracy of ± 2mm, it is far superior to conventional liquid level instruments and suitable for high-precision control scenarios.
Strong adaptability to working conditions304 stainless steel probe and flange, suitable for various media such as water, oil, acid-base solutions, organic solvents, etc; The operating conditions of 50 ℃ room temperature and 0.007-0.12MPa micro positive pressure cover the vast majority of industrial conventional containers, and operate stably in the vacuum to micro positive pressure range without measurement blind spots or signal attenuation problems.
Intelligent, convenient and easy to useIntegrated HART communication protocol, supports remote range modification, zero calibration, and fault inquiry using handheld terminals or upper computers, without the need for cover opening operations. The on-site LCD display is intuitive and clear, supporting switching between Chinese and English. It can directly read real-time liquid level, output current, and working condition status, reducing the difficulty of on-site debugging and maintenance. Two wire wiring simplifies wiring, with 24VDC power supply compatible with industrial standard power supply, and plug and play installation.
Reliable, durable, and maintenance freeAll solid state electronic components, no mechanical wear parts, no risk of jamming or damage, and long-term operation without the need for cleaning, calibration, or component replacement. The IP67 protective shell resists moisture, dust, and slight corrosion, while the 304 material probe is resistant to medium erosion, maintaining long-term stability under complex working conditions and significantly reducing operation and maintenance costs.
Secure compatibility and adaptationStandard 4-20mA+HART output, compatible with various industrial control systems, no additional adapter module required. The top mounted design is suitable for various vertical containers, and the DN50 standard flange has strong universality, which can directly replace traditional instruments such as floats, capacitors, and magnetic level gauges. The modification does not require changing the container interface.
chemical industryMonitoring of liquid levels in acid-base storage tanks, solvent storage tanks, intermediate reaction vessels, and buffer tanks at room temperature and pressure;
power industryMeasurement of liquid levels in the clean water tank, waste water tank, and dosing tank of the water treatment system;
Food and pharmaceutical industrySanitary grade liquid level control for purified water tanks, syrup tanks, medicine storage tanks, and ingredient tanks;